Supported Platforms
Related Documentation
- ACX, EX, M, MX, SRX, T Series
- action
- syslog
- link-down
- send-critical-event
- ACX, EX, M, MX, T Series
- IEEE 802.3ah OAM Link-Fault Management Overview
- Configuring IEEE 802.3ah OAM Link-Fault Management
- Enabling IEEE 802.3ah OAM Support
- Configuring Link Discovery
- Configuring the OAM PDU Interval
- Configuring the OAM PDU Threshold
- Configuring Threshold Values for Local Fault Events on an Interface
- Disabling the Sending of Link Event TLVs
- Detecting Remote Faults
- Configuring an OAM Action Profile
- Monitoring the Loss of Link Adjacency
- Monitoring Protocol Status
- Configuring Threshold Values for Fault Events in an Action Profile
- Applying an Action Profile
- Setting a Remote Interface into Loopback Mode
- Example: Configuring IEEE 802.3ah OAM Support on an Interface
- ACX, EX, MX, T Series
- Enabling Remote Loopback Support on the Local Interface
- Additional Information
- Ethernet Interfaces
Specifying the Actions to Be Taken for Link-Fault Management Events
You can specify the action to be taken by the system when the configured link-fault event occurs. Multiple action profiles can be applied to a single interface. For each action-profile, at least one event and one action must be specified. The actions are taken only when all of the events in the action profile are true. If more than one action is specified, all the actions are executed.
You might want to set a lower threshold for a specific action such as logging the error and set a higher threshold for another action such as sending a critical event TLV.
To specify the action, include the action statement at the [edit protocols oam ethernet link-fault-management action-profile profile-name] hierarchy level:
To create a system log entry when the link-fault event occurs, include the syslog statement.
To administratively disable the link when the link-fault event occurs, include the link-down statement.
To send IEEE 802.3ah link event TLVs in the OAM PDU when a link-fault event occurs, include the send-critical-event statement.
![]() | Note: If multiple actions are specified in the action profile, all of the actions are executed in no particular order. |
Related Documentation
- ACX, EX, M, MX, SRX, T Series
- action
- syslog
- link-down
- send-critical-event
- ACX, EX, M, MX, T Series
- IEEE 802.3ah OAM Link-Fault Management Overview
- Configuring IEEE 802.3ah OAM Link-Fault Management
- Enabling IEEE 802.3ah OAM Support
- Configuring Link Discovery
- Configuring the OAM PDU Interval
- Configuring the OAM PDU Threshold
- Configuring Threshold Values for Local Fault Events on an Interface
- Disabling the Sending of Link Event TLVs
- Detecting Remote Faults
- Configuring an OAM Action Profile
- Monitoring the Loss of Link Adjacency
- Monitoring Protocol Status
- Configuring Threshold Values for Fault Events in an Action Profile
- Applying an Action Profile
- Setting a Remote Interface into Loopback Mode
- Example: Configuring IEEE 802.3ah OAM Support on an Interface
- ACX, EX, MX, T Series
- Enabling Remote Loopback Support on the Local Interface
- Additional Information
- Ethernet Interfaces
Published: 2013-08-28
Supported Platforms
Related Documentation
- ACX, EX, M, MX, SRX, T Series
- action
- syslog
- link-down
- send-critical-event
- ACX, EX, M, MX, T Series
- IEEE 802.3ah OAM Link-Fault Management Overview
- Configuring IEEE 802.3ah OAM Link-Fault Management
- Enabling IEEE 802.3ah OAM Support
- Configuring Link Discovery
- Configuring the OAM PDU Interval
- Configuring the OAM PDU Threshold
- Configuring Threshold Values for Local Fault Events on an Interface
- Disabling the Sending of Link Event TLVs
- Detecting Remote Faults
- Configuring an OAM Action Profile
- Monitoring the Loss of Link Adjacency
- Monitoring Protocol Status
- Configuring Threshold Values for Fault Events in an Action Profile
- Applying an Action Profile
- Setting a Remote Interface into Loopback Mode
- Example: Configuring IEEE 802.3ah OAM Support on an Interface
- ACX, EX, MX, T Series
- Enabling Remote Loopback Support on the Local Interface
- Additional Information
- Ethernet Interfaces