ieee-802.1
Syntax
- ieee-802.1 classifier-name {
-
import (classifier-name | default);
-
-
forwarding-class
class-name {
-
-
loss-priority
level {
-
code-points [ aliases ] [ 6 bit-patterns ];
- }
- }
- }
Hierarchy Level
- [edit class-of-service
classifiers],
[edit class-of-service
code-point-aliases],
[editclass-of-service
interfaces
interface-name
unit
logical-unit-number
classifiers],
[edit class-of-service
rewrite-rules]
Release Information
Statement introduced in JUNOS Release 9.0 for EX-series switches.
Description
Apply an IEEE-802.1 rewrite rule.
Options
-
classifier-name —Name of the classifier.
-
The remaining statements are explained separately.
Required Privilege Level
routing—To view this statement in the
configuration.
routing-control—To add this statement