SCBE2-MX LEDs
FABRIC ACTIVE
, FABRIC ONLY
, and OK/FAIL
LEDs indicate the status of the
SCBE2-MX. The BITS
, GPS
,
and UTI
LEDs, located next to the EXT
CLK
port, indicate the status of the respective clocking
interface. The LINK
LED located next to the two
Ethernet ports, indicate the status of the respective SFP+ interface. Table 1 describes the
functions of the SCBE2-MX LEDs.
Table 1: SCBE2-MX LEDs
Label | Color | State | Description |
---|---|---|---|
| Green | On steadily | Fabric is in active mode. |
| Green | On steadily | SCBE2-MX operates in fabric-only mode. |
– | Off | SCBE2-MX operates in fabric or control-board mode. | |
| Green | On steadily | SCBE2-MX is online. |
Red | On steadily | SCBE2-MX has failed. | |
– | Off | SCBE2-MX is offline. | |
| Green | On steadily | Building-integrated timing supply (BITS) clocking interface is active. |
Red | On steadily | BITS clocking interface has failed. | |
– | Off | BITS clocking interface is offline. | |
| Green | On steadily | Global positioning system (GPS) clocking interface is active. |
Red | On steadily | GPS clocking interface has failed. | |
– | Off | GPS clocking interface is offline. | |
| Green | On steadily | Universal Timing Interface (UTI) clocking interface is active. |
Red | On steadily | UTI clocking interface has failed. | |
– | Off | UTI clocking interface is offline. | |
| Green | On steadily | Port is enabled and link is established. |
– | Off | Port is disabled or no link is established. |