- play_arrow Fast Track: Initial Installation
- play_arrow Overview
- play_arrow MX2010 Router Overview
- play_arrow Chassis Components and Descriptions
- MX Series Router Architecture
- MX2010 Chassis Description
- MX2010 Backplane Description
- MX2010 Component Redundancy
- MX2010 Field-Replaceable Units
- MX Series Router Packet Forwarding Engine (PFE) Architecture
- Line Cards Supported on MX Series Routers
- Ethernet Frame Counts and Statistics on MX Series Routers
- Understanding Trio Layer 2 Feature Parity
- MX2010 Router Hardware Components and CLI Terminology
- play_arrow Alarm and Display Components
- play_arrow Cable and Rack Management
- play_arrow Cooling System
- play_arrow Host Subsystem Components
- MX2000 Host Subsystem CB-RE Description
- RE-MX2000-1800x4 CB-RE Description
- REMX2K-X8-64G and REMX2K-X8-64G-LT CB-RE Description
- REMX2K-X8-128G CB-RE Description
- CB-RE LEDs
- MX2000 Switch Fabric Board (SFB) Overview
- MX2000-SFB-S Switch Fabric Board Description
- MX2000-SFB2-S Enhanced Switch Fabric Board Description
- MX2000-SFB3 Switch Fabric Board Description
- MX2000 Switch Fabric Board LED
- play_arrow Interface Modules— ADCs, MPCs, and MICs
- MX Series Interface Module Reference
- MX2000 Adapter Card (ADC) Description
- MX2010 Modular Port Concentrator Description
- MPCs Supported by MX Series Routers
- MX2010 Modular Port Concentrator LEDs
- MX2010 MPC Terminology
- MX2010 Modular Interface Card Description
- MICs Supported by MX Series Routers
- MX2010 Modular Interface Card LEDs
- MX2010 Port and Interface Numbering
- play_arrow Power System
- MX2010 Power System Description
- MX2010 Power Midplane Description
- MX2000 Three-Phase Delta AC Power Distribution Module Description
- MX2000 Three-Phase Wye AC Power Distribution Module Description
- MX2000 Seven-Feed Single-Phase AC Power Distribution Module Description
- MX2000 Nine-Feed Single-Phase AC Power Distribution Module Description
- MX2000 Three-Phase Delta and Wye AC Power Distribution Module LEDs
- MX2000 AC Power Supply Module Description
- MX2010 AC Power Supply Module LEDs
- MX2010 DC Power Distribution Module (-48 V) Description
- MX2000 DC Power Distribution Module (240 V China) Description
- MX2010 DC Power Distribution Module (-48 V) LEDs
- MX2000 DC Power Distribution Module (240 V China) LEDs
- MX2010 DC Power Supply Module (-48 V) Description
- MX2000 DC Power Supply Module (240 V China) Description
- MX2010 DC Power Supply Module LEDs
- MX2010 High-Voltage Universal (HVAC/HVDC) Power Distribution Module Description
- MX2010 High-Voltage Universal (HVAC/HVDC) Power Distribution Module LEDs
- MX2010 High-Voltage Universal (HVAC/HVDC) Power Supply Module Description
- MX2010 High-Voltage Universal (HVAC/HVDC) Power Supply Module LEDs
-
- play_arrow Site Planning, Preparation, and Specifications
- play_arrow Planning and Preparing the Site
- Overview of Preparing the Site for the MX2010 Router
- MX2010 Cabinet Airflow Requirements
- MX2010 Cabinet Size and Clearance Requirements
- MX2010 Chassis Moving Guidelines
- MX2010 Physical Specifications
- MX2010 Rack Requirements
- MX2010 Router Transport Kit Moving Requirements and Guidelines
- MX2010 Router Environmental Specifications
- MX2000 Router Grounding Specifications
- MX2010 Site Preparation Checklist
- Clearance Requirements for Airflow and Hardware Maintenance for the MX2010 Router
- play_arrow Transceiver and Cable Specifications
- play_arrow Pinout Specifications
- play_arrow AC Power Requirements, Specifications, and Guidelines
- MX2010 AC Power Requirements
- MX2000 AC Power Cord Specifications
- MX2000 AC Power System Electrical Specifications
- MX2000 Router Grounding Specifications
- MX2000 Three-Phase Delta AC Power Distribution Module Electrical Specifications
- MX2000 Three-Phase Wye AC Power Distribution Module Electrical Specifications
- MX2000 Single-Phase AC Power Distribution Module Electrical Specifications
- Calculating AC Power Requirements for MX2010 Routers
- Mapping Input Power from AC Power Distribution Modules to AC Power Supply Modules on MX2000 Routers
- play_arrow DC Power Requirements, Specifications, and Guidelines
- MX2010 DC Power Requirements
- MX2010 DC Power Distribution Description (-48 V)
- MX2010 DC Power Distribution (240 V China) Description
- MX2010 DC Power (-48 V) System Electrical Specifications
- MX2010 Router DC (240 V China) System Electrical Specifications
- Calculating DC Power Requirements for MX2010 Routers
- DC Power (-48 V) Circuit Breaker Requirements for the MX2010 Router
- DC Power (240 V China) Circuit Breaker Requirements for the MX2000 Router
- DC Power Cable Specifications for the MX2010 Router
- play_arrow Universal (HVAC/HVDC) Power Requirements, Specifications, and Guidelines
- MX2010 High-Voltage Universal (HVAC/HVDC) Power Requirements
- MX2000 High-Voltage Universal PDM (MX2K-PDM-HV) Power Cord Specifications
- MX2000 Router High-Voltage Universal (HVAC/HVDC) Power Subsystem Electrical Specifications
- Determining High-Voltage Universal (HVAC/HVDC) Power Requirements for Your MX2010 Router
- High-Voltage Universal (HVAC/HVDC) Power Circuit Breaker Requirements for the MX2000 Router
-
- play_arrow Initial Installation and Configuration
- play_arrow Installation Overview
- Installing an MX2010 Router Overview
- Tools and Parts Required to Unpack the MX2010 Router
- Tools Required to Install the MX2010 Router Using a Pallet Jack
- Tools Required to Install the MX2010 Router Using a Router Transport Kit
- Tools and Parts Required to Maintain the MX2010 Hardware Components
- Tools and Parts Required for Connecting an MX2000 Router to Power
- Tools and Parts Required for MX2010 Router Connections
- play_arrow Unpacking the Router
- play_arrow Installing the Mounting Hardware
- play_arrow Installing the Router
- Removing Components from the MX2010 Router Chassis Before Installing It in a Rack
- Installing an MX2010 Router Using a Pallet Jack Overview
- Installing the Pallet Jack Attachment
- Installing the MX2010 Router Using a Pallet Jack with Attachment
- Installing an MX2010 Router Using a Router Transport Kit Overview
- Installing the Router Transport Kit on the MX2010 Router
- Securing the MX2010 Router to the Router Transport Platform
- Using the Router Transport Kit to Install the MX2010 Router in a Four-Post Rack
- Using the Router Transport Kit to Install the MX2010 Router in an Open-Frame Rack
- Reinstalling Components in the MX2000 Router After Initially Installing the Router in a Rack
- play_arrow Connecting the Router to Power
- Grounding an MX2000 Router
- Connecting AC Power to an MX2000 Router with Three-Phase Delta AC Power Distribution Modules
- Connecting AC Power to an MX2000 Router with Three-Phase Wye AC Power Distribution Modules
- Connecting Power to an MX2000 Single-Phase AC Power Distribution Module
- Mapping Input Power from AC Power Distribution Modules to AC Power Supply Modules on MX2000 Routers
- Connecting Power to a DC-Powered MX2010 Router with Power Distribution Modules (-48 V)
- Connecting Power to a DC-Powered MX2000 Router with DC Power Distribution Modules (240 V China)
- Connecting Power to a High Voltage-Powered MX2000 Router with Power Distribution Modules
- Connecting an MX2000 DC Router Power Distribution Module (-48 V) Cable
- Connecting an MX2000 DC Router Power Distribution Module (240 V China) Cable
- Powering On the DC-Powered MX2010 Router
- Powering On the DC-Powered (240 V China) MX2000 Router
- Powering On the High-Voltage Powered Universal (HVAC/HVDC) MX2000 Router
- Powering On a Three-Phase AC-Powered MX2000 Router
- play_arrow Connecting the Router to the Network
- Connecting the MX2010 Router to Management and Alarm Devices
- Connecting the MX2010 Router to a Network for Out-of-Band Management
- Connecting an MX2000 Router to a Console or Auxiliary Device
- Connecting an MX2010 Router to an External Alarm-Reporting Device
- Connecting the Alarm Relay Wires to the MX2010 Craft Interface
- Disconnecting the Alarm Relay Wires from the MX2010 Craft Interface
- Connecting MPC or MIC Cables to the MX2010 Router
- Register Products—Mandatory to Validate SLAs
- play_arrow Initially Configuring the Router
-
- play_arrow Installing and Replacing Components
- play_arrow Installing Components
- Installing an MX2010 Adapter Card
- Installing the MX2010 Air Filter
- Installing the MX2010 Craft Interface
- Installing the MX2010 Standard DC Cable Manager
- Installing an MX2000 Router DC Power Distribution Module (-48 V)
- Installing an MX2000 Router DC Power Distribution Module (240 V China)
- Installing an MX2000 Router High-Voltage Universal (HVAC/HVDC) Power Distribution Module
- Installing an MX2010 DC Power Supply Module (-48 V)
- Installing MX2000 Router DC Power Supply Modules (240 V China)
- Installing MX2000 Router High-Voltage Universal (HVAC/HVDC) Power Supply Modules
- Installing an MX2010 Dual-Wide MIC
- Installing the MX2010 Standard EMI Cover
- Installing the MX2010 Extended EMI Cover
- Installing an MX2010 Fan Tray
- Installing the MX2010 Air Baffle
- Installing the MX2010 Standard Cable Manager
- Installing the MX2010 Extended Cable Manager
- Installing the MX2010 Extended DC Cable Manager
- Installing an MX2010 MIC
- Installing an MX2000 SFB
- Installing an MX2010 CB-RE
- Installing MX2000 Router AC Power Supply Modules
- Installing MX2000 Router DC Power Supply Modules (-48 V)
- Installing an MX2000 Router Three-Phase Delta AC Power Distribution Module
- Installing an MX2000 Router Three-Phase Wye AC Power Distribution Module
- Installing an MX2000 Single-Phase AC Power Distribution Module
- Installing an SFP or XFP into an MX2000 MPC or MIC
- play_arrow Replacing Components
- Tools and Parts Required for Replacing MX2010 Hardware Components
- Tools and Parts Required to Remove Components from an MX2010 Router
- Removing a CB-RE from an MX2000 Router
- Upgrading to the Control Board-Routing Engine REMX2K-X8-64G in a Redundant Host Subsystem
- Upgrading to the REMX2K-X8-64G CB-RE in a Nonredundant Host Subsystem
- Replacing a Cable on an MX2010 MPC or MIC
- Replacing the MX2010 Air Filters
- Replacing the MX2010 Standard Cable Managers
- Replacing the MX2010 Extended Cable Manager
- Replacing the MX2010 Craft Interface
- Replacing an MX2010 DC Power Supply Module (-48 V)
- Replacing an MX2000 DC Power Supply Module (240 V China)
- Replacing an MX2000 High-Voltage Second-Generation Universal (HVAC/HVDC) Power Supply Module
- Replacing an MX2000 DC Power Distribution Module (-48 V)
- Replacing an MX2000 DC Power Distribution Module (240 V China)
- Replacing an MX2000 High-Voltage Universal (HVAC/HVDC) Power Distribution Module
- Replacing an MX2010 DC Power Distribution Module Cable
- Connecting an MX2000 DC Router Power Distribution Module (240 V China) Cable
- Replacing the MX2010 Standard EMI Cover
- Replacing the MX2010 Extended EMI Cover
- Replacing an MX2010 Fan Tray
- Replacing the MX2010 Air Baffle
- Replacing an MX2010 MIC
- Replacing an MX2010 MPC and Adapter Card
- Replacing an MX2000 SFB
- Replacing an MX2000 CB-RE
- Replacing an SFP or XFP Transceiver on an MX2010 MPC or MIC
- Replacing an MX2000 AC Power Supply Module
- Replacing an MX2010 Three-Phase Delta AC Power Cord
- Replacing an MX2000 Three-Phase Delta AC Power Distribution Module
- Replacing an MX2010 Three-Phase Wye AC Power Cord
- Replacing an MX2020 Three-Phase Wye AC Power Distribution Module
-
- play_arrow Maintaining the Chassis and Components
- play_arrow Maintaining Components
- Maintaining the MX2010 Adapter Cards
- Maintaining Cables That Connect to MX2010 MPCs or MICs
- Maintaining and Verifying the Status of the MX2010 Router Components
- Maintaining the MX2010 Air Filters
- Maintaining the MX2010 Air Vents
- Maintaining the MX2010 Chassis FRU Power-On Sequence
- Maintaining the MX2010 Control Boards
- Maintaining the MX2010 Cooling System Components
- Maintaining the MX2010 Cooling System Zones
- Maintaining the MX2010 Ethernet Switch
- Maintaining the MX2010 Fan Trays
- Maintaining the MX2010 Air Baffle
- Maintaining the MX2010 Host Subsystem
- Maintaining MX2010 MICs
- Maintaining MX2010 MPCs
- Maintaining MX2010 Packet Forwarding Engine Components
- Maintaining the Power Supply Modules on the MX2000 Line of Routers
- Maintaining the MX2010 Power Usage
- Converting an MX2000 Router Between AC and DC Power
- Maintaining the MX2010 Routing Engines
- Maintaining the MX2010 SFB
- Maintaining the MX2010 Switch Processor Mezzanine Board (SPMB)
- Maintaining and Verifying the MX2010 Router Version
- Maintaining and Verifying the Status of the MX2010 Craft Interface
- Taking an MX2000 Host Subsystem Offline
- Holding an MX2010 MPC
- Storing an MX2010 MPC
- Routine Maintenance Procedures for the MX2010 Router
- play_arrow Packing and Returning Components
- play_arrow Powering Off the Router
-
- play_arrow Troubleshooting Hardware
- play_arrow Safety and Compliance Information
- play_arrow General Safety Guidelines and Warnings
- play_arrow Installation and Maintenance Safety Guidelines and Warnings
- play_arrow Radiation and Laser Warnings
- play_arrow Maintenance and Operational Safety Guidelines and Warnings
- play_arrow Electrical Safety Guidelines and Warnings
- General Electrical Safety Guidelines and Warnings
- Prevention of Electrostatic Discharge Damage
- AC Power Electrical Safety Guidelines
- AC Power Disconnection Warning
- DC Power Copper Conductors Warning
- DC Power Disconnection Warning
- DC Power Grounding Requirements and Warning
- DC Power Wiring Sequence Warning
- DC Power Wiring Terminations Warning
- Midplane Energy Hazard Warning
- Multiple Power Supplies Disconnection Warning
- Action to Take After an Electrical Accident
- play_arrow Agency Approvals and Compliance Statements
-
Displaying MX2010 Router Components and Serial Numbers
Before contacting Juniper Networks, Inc. to request a Return Materials Authorization (RMA), you must find the serial number on the router or component. To display all the router components and their serial numbers, enter the following command-line interface (CLI) command:
The sample output below shows the AC power chassis hardware:
user@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis JN11E26D3AFK MX2010 Midplane REV 01 750-044636 ABAB8511 Lower Backplane Midplane 1 REV 01 711-044557 ZY8294 Upper Backplane PMP REV 03 711-032426 ACAJ1389 Power Midplane FPM Board REV 06 711-032349 ZX8742 Front Panel Display PSM 0 Rev 0C 740-033726 WA00018 AC 52V Power Supply Module PSM 1 Rev 0C 740-033726 WA00062 AC 52V Power Supply Module PSM 2 Rev 0C 740-033726 WA00034 AC 52V Power Supply Module PSM 3 Rev 0C 740-033726 WA00048 AC 52V Power Supply Module PSM 4 Rev 0C 740-033726 WA00092 AC 52V Power Supply Module PSM 5 Rev 0C 740-033726 WA00020 AC 52V Power Supply Module PSM 6 Rev 0C 740-033726 WA00002 AC 52V Power Supply Module PDM 0 REV 0D 740-038281 VK00013 AC Y Power Dist Module PDM 1 REV 0D 740-038281 VK00009 AC Y Power Dist Module Routing Engine 0 REV 02 740-041821 9009094145 RE-S-1800x4 Routing Engine 1 REV 02 740-041821 9009094136 RE-S-1800x4 CB 0 REV 08 750-040257 CAAB3490 Control Board CB 1 REV 08 750-040257 CAAB3481 Control Board SPMB 0 REV 02 711-041855 CAAA6136 SPMB 1 REV 02 711-041855 CAAA6145 PMB Board SFB 0 REV 07 711-032385 ZZ2589 Switch Fabric Board SFB 1 REV 07 711-032385 ZZ2571 Switch Fabric Board SFB 2 REV 07 711-032385 CAAB4886 Switch Fabric Board SFB 3 REV 07 711-032385 CAAB4906 Switch Fabric Board SFB 4 REV 06 711-032385 ZV1826 Switch Fabric Board SFB 5 REV 07 711-032385 CAAB4900 Switch Fabric Board SFB 6 REV 06 711-032385 ZV1821 Switch Fabric Board SFB 7 REV 06 711-032385 ZV8471 Switch Fabric Board FPC 0 REV 09 750-038490 ZN7120 MPCE Type 1 3D Q CPU REV 04 711-038484 ZZ4585 MPCE PMB 2G MIC 0 REV 26 750-028392 CAAC5653 3D 20x 1GE(LAN) SFP PIC 0 BUILTIN BUILTIN 10x 1GE(LAN) SFP Xcvr 0 REV 02 740-011613 PH40QAV SFP-SX Xcvr 1 REV 01 740-011613 P9F16YM SFP-SX Xcvr 8 REV 01 740-011613 P8E2SSX SFP-SX Xcvr 9 REV 01 740-011613 PCD4FLT SFP-SX PIC 1 BUILTIN BUILTIN 10x 1GE(LAN) SFP Xcvr 0 REV 01 740-013111 6482546 SFP-T Xcvr 1 REV 02 740-013111 9277936 SFP-T Xcvr 8 REV 01 740-011782 PB832A0 SFP-SX Xcvr 9 REV 02 740-011613 PGL36GR SFP-SX MIC 1 REV 21 750-028380 ZZ0840 3D 2x 10GE XFP PIC 2 BUILTIN BUILTIN 1x 10GE XFP Xcvr 0 REV 02 740-014289 C826XU08J XFP-10G-SR PIC 3 BUILTIN BUILTIN 1x 10GE XFP Xcvr 0 REV 02 740-014289 T10A30227 XFP-10G-SR QXM 0 REV 06 711-028408 ZY8200 MPC QXM FPC 1 REV 08 750-038491 ZY8894 MPCE Type 2 3D CPU REV 04 711-038484 ZZ4574 MPCE PMB 2G MIC 1 REV 27 750-028387 CAAB4862 3D 4x 10GE XFP PIC 2 BUILTIN BUILTIN 2x 10GE XFP Xcvr 0 REV 03 740-014289 C907BQ026 XFP-10G-SR PIC 3 BUILTIN BUILTIN 2x 10GE XFP FPC 2 REV 03 750-045372 CAAD9393 MPCE Type 3 3D CPU REV 08 711-035209 CAAD9067 HMPC PMB 2G MIC 0 REV 02 750-028380 JG8549 3D 2x 10GE XFP PIC 0 BUILTIN BUILTIN 1x 10GE XFP Xcvr 0 NON-JNPR T10A91680 XFP-10G-SR PIC 1 BUILTIN BUILTIN 1x 10GE XFP Xcvr 0 REV 03 740-014289 C907BQ00T XFP-10G-SR MIC 1 REV 10 750-033199 YX4509 1X100GE CFP PIC 2 BUILTIN BUILTIN 1X100GE CFP Xcvr 0 REV 01 740-045420 UNE902 CFP-100G-ER4 FPC 4 REV 03 750-045372 CAAD9452 MPCE Type 3 3D CPU REV 08 711-035209 CAAD9034 HMPC PMB 2G MIC 0 REV 21 750-028380 ZY2980 3D 2x 10GE XFP PIC 0 BUILTIN BUILTIN 1x 10GE XFP Xcvr 0 NON-JNPR T09K08083 XFP-10G-SR PIC 1 BUILTIN BUILTIN 1x 10GE XFP Xcvr 0 REV 01 740-014289 98S803A90378 XFP-10G-SR MIC 1 REV 08 750-036233 CAAM1168 2X40GE QSFP PIC 2 BUILTIN BUILTIN 2X40GE QSFP Xcvr 0 REV 01 740-043308 2XDX44N00007 QSFP+-40G-LR4 Xcvr 1 REV 01 740-046565 QC480260 QSFP+-40G-SR4 FPC 6 REV 17 750-037355 CAAT3989 MPC4E 3D 2CGE+8XGE CPU REV 08 711-035209 CAAR3985 HMPC PMB 2G PIC 0 BUILTIN BUILTIN 4x10GE SFPP Xcvr 3 REV 01 740-031981 ALT19NU SFP+-10G-LR PIC 1 BUILTIN BUILTIN 1X100GE CFP Xcvr 0 REV 01 740-035329 UN1085T CFP-100G-SR10 PIC 2 BUILTIN BUILTIN 4x10GE SFPP Xcvr 3 REV 01 740-031981 ALT19N6 SFP+-10G-LR PIC 3 BUILTIN BUILTIN 1X100GE CFP Xcvr 0 REV 01 740-035329 UMS06WS CFP-100G-SR10 FPC 9 REV 11 750-036284 ZL3660 MPC 3D 16x 10GE EM CPU REV 10 711-029089 ZK8306 AMPC PMB PIC 0 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-031980 AJ71KEH SFP+-10G-SR Xcvr 3 REV 01 740-031980 B11F00069 SFP+-10G-SR PIC 1 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ PIC 2 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-031980 AMB0HYT SFP+-10G-SR PIC 3 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ ADC 0 REV 07 750-043596 ABBV7171 Adapter Card ADC 1 REV 05 750-043596 ZZ6194 Adapter Card ADC 2 REV 06 750-043596 ABBT3817 Adapter Card ADC 4 REV 01 750-032317 ZJ0343 ADC Etch1 ADC 6 REV 05 750-043596 ZZ6200 Adapter Card ADC 9 REV 13 750-043596 ABBX5549 Adapter Card Fan Tray 0 REV 06 760-046960 ACAY0274 172mm FanTray - 6 Fans Fan Tray 1 REV 06 760-046960 ACAY0273 172mm FanTray - 6 Fans Fan Tray 2 REV 06 760-046960 ACAY0272 172mm FanTray - 6 Fans Fan Tray 3 REV 06 760-046960 ACAY0271 172mm FanTray - 6 Fans
The sample output below shows the DC power chassis hardware:
user@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis JN120BCC4AFK MX2010 Midplane REV 35 750-044636 ABAB8695 Lower Backplane Midplane 1 REV 02 711-044557 ABAB9172 Upper Backplane PMP REV 04 711-032426 ACAJ1887 Power Midplane FPM Board REV 09 760-044634 ABCA1163 Front Panel Display PSM 0 REV 03 740-045050 1EDB23500AZ DC 52V Power Supply Module PSM 1 REV 01 740-045050 1E022240006 DC 52V Power Supply Module PSM 2 REV 03 740-045050 1EDB2350091 DC 52V Power Supply Module PSM 3 REV 01 740-045050 1E02224000X DC 52V Power Supply Module PSM 4 REV 03 740-045050 1EDB235008Y DC 52V Power Supply Module PSM 5 REV 01 740-045050 1E02224000D DC 52V Power Supply Module PSM 6 REV 01 740-045050 1E02224001D DC 52V Power Supply Module PSM 7 REV 01 740-045050 1E02224001B DC 52V Power Supply Module PSM 8 REV 01 740-045050 1E022240007 DC 52V Power Supply Module PDM 0 REV 01 740-045234 1E262250067 DC Power Dist Module Routing Engine 0 REV 02 740-041821 9009110761 RE-S-1800x4 Routing Engine 1 REV 02 740-041821 9009099703 RE-S-1800x4 CB 0 REV 20 750-040257 CAAL2942 Control Board CB 1 REV 13 750-040257 CAAF8435 Control Board SPMB 0 REV 02 711-041855 ABBX0406 PMB Board SPMB 1 SFB 0 REV 05 711-044466 ABBT2142 Switch Fabric Board SFB 1 REV 05 711-044466 ABBT2144 Switch Fabric Board SFB 2 REV 05 711-044466 ABBT2151 Switch Fabric Board SFB 3 REV 05 711-044466 ABBT2140 Switch Fabric Board SFB 4 REV 05 711-044466 ABBT2148 Switch Fabric Board SFB 5 REV 05 711-044466 ABBT2146 Switch Fabric Board SFB 6 REV 05 711-044466 ABBT2143 Switch Fabric Board SFB 7 REV 05 711-044466 ABBT2147 Switch Fabric Board FPC 1 REV 36 750-028467 CAAS7536 MPC 3D 16x 10GE CPU FPC 2 REV 06 750-036284 YZ6735 MPCE 3D 16x 10GE CPU FPC 3 REV 33 750-028467 CAAF5552 MPC 3D 16x 10GE CPU FPC 4 REV 16.0.05 750-044130 ABCA5352 MPC6E 3D CPU REV 07 711-045719 ABCA5141 RMPC PMB FPC 6 REV 16.0.05 750-044130 ABCC0320 MPC6E 3D CPU REV 07 711-045719 ABCA3870 RMPC PMB MIC 0 REV 07 750-046535 ABBZ9635 24X10GE SFPP PIC 0 BUILTIN BUILTIN 24X10GE SFPP Xcvr 0 REV 01 740-021308 ANA03FH SFP+-10G-SR Xcvr 1 REV 01 740-021308 ANA0MX7 SFP+-10G-SR Xcvr 2 REV 01 740-021308 ANA0QHL SFP+-10G-SR Xcvr 3 REV 01 740-021308 973152A00022 SFP+-10G-SR Xcvr 4 REV 01 740-021308 ANA0MZA SFP+-10G-SR Xcvr 5 REV 01 740-021308 ANA0Q2W SFP+-10G-SR Xcvr 6 REV 01 740-021308 ANA0N5L SFP+-10G-SR Xcvr 7 REV 01 740-021308 ANA0NJ1 SFP+-10G-SR Xcvr 8 REV 01 740-021308 ANA0N5C SFP+-10G-SR Xcvr 9 REV 01 740-021308 ANA0MMT SFP+-10G-SR Xcvr 10 REV 01 740-021308 ANA09VW SFP+-10G-SR Xcvr 11 REV 01 740-021308 ANA09VV SFP+-10G-SR Xcvr 12 REV 01 740-021308 ANA0QLB SFP+-10G-SR Xcvr 13 REV 01 740-021308 ANA0MMS SFP+-10G-SR Xcvr 14 REV 01 740-021308 ANA0NHP SFP+-10G-SR Xcvr 15 REV 01 740-021308 ANA0NFD SFP+-10G-SR Xcvr 16 REV 01 740-021308 ANA0NJE SFP+-10G-SR Xcvr 17 REV 01 740-021308 ANA0QGF SFP+-10G-SR Xcvr 18 REV 01 740-021308 ANA0N82 SFP+-10G-SR Xcvr 19 REV 01 740-021308 ANA0QHH SFP+-10G-SR Xcvr 20 REV 01 740-021308 ANA03FF SFP+-10G-SR Xcvr 21 REV 01 740-021308 ANA0NCY SFP+-10G-SR Xcvr 22 REV 01 740-021308 ANA0BMF SFP+-10G-SR Xcvr 23 REV 01 740-021308 ANA0BMQ SFP+-10G-SR MIC 1 REV 07 750-046535 ABBZ9639 24X10GE SFPP PIC 1 BUILTIN BUILTIN 24X10GE SFPP Xcvr 0 REV 01 740-021308 ANA0NDW SFP+-10G-SR Xcvr 1 REV 01 740-021308 ANA0PXK SFP+-10G-SR Xcvr 2 REV 01 740-021308 ANA0QG7 SFP+-10G-SR Xcvr 3 REV 01 740-021308 ANA0QJQ SFP+-10G-SR Xcvr 4 REV 01 740-021308 ANA0MLR SFP+-10G-SR Xcvr 5 REV 01 740-021308 ANA0PXW SFP+-10G-SR Xcvr 6 REV 01 740-021308 ANA0MZC SFP+-10G-SR Xcvr 7 REV 01 740-021308 ANA0PXU SFP+-10G-SR Xcvr 8 REV 01 740-021308 ANA0NFH SFP+-10G-SR Xcvr 9 REV 01 740-021308 ANA09YS SFP+-10G-SR Xcvr 10 REV 01 740-021308 ANA0NG6 SFP+-10G-SR Xcvr 11 REV 01 740-021308 ANA0N5B SFP+-10G-SR Xcvr 12 REV 01 740-021308 ANA0QJT SFP+-10G-SR Xcvr 13 REV 01 740-021308 ANA0MME SFP+-10G-SR Xcvr 14 REV 01 740-021308 ANA0PY4 SFP+-10G-SR Xcvr 15 REV 01 740-021308 ANA0PXH SFP+-10G-SR Xcvr 16 REV 01 740-021308 ANA0NGY SFP+-10G-SR Xcvr 17 REV 01 740-021308 ANA0PY1 SFP+-10G-SR Xcvr 18 REV 01 740-021308 ANA0QG4 SFP+-10G-SR Xcvr 19 REV 01 740-021308 ANA0MLW SFP+-10G-SR Xcvr 20 REV 01 740-021308 ANA0QHZ SFP+-10G-SR Xcvr 21 REV 01 740-021308 ANA0NGA SFP+-10G-SR Xcvr 22 REV 01 740-021308 ANA0QJ3 SFP+-10G-SR Xcvr 23 REV 01 740-021308 ANA0NDV SFP+-10G-SR ADC 1 REV 13 750-043596 ABBX5578 Adapter Card ADC 2 REV 13 750-043596 ABBX5572 Adapter Card ADC 3 REV 07 750-043596 ABBV7188 Adapter Card ADC 5 REV 13 750-043596 ABBX5552 Adapter Card ADC 7 REV 13 750-043596 ABBX5546 Adapter Card ADC 8 REV 13 750-043596 ABBX5561 Adapter Card ADC 9 REV 13 750-043596 ABBX5559 Adapter Card Fan Tray 0 REV 06 760-046960 ACAY0207 172mm FanTray - 6 Fans Fan Tray 1 REV 06 760-046960 ACAY0209 172mm FanTray - 6 Fans Fan Tray 2 REV 06 760-046960 ACAY0227 172mm FanTray - 6 Fans Fan Tray 3 REV 06 760-046960 ACAY0229 172mm FanTray - 6 Fans
Most components also have a small rectangular serial number ID label attached to the component body (see Figure 1).
