Router Environmental Tolerances

Table 34 specifies the environmental conditions required for normal Services Router operation. In addition, the site must be as dust-free as possible. Dust can clog air intake vents, reducing cooling system efficiency. Check vents frequently, cleaning them as necessary.

Table 34: Router Environmental Tolerances

Description

Value

Altitude

No performance degradation to 10,000 ft (3048 m)

Relative humidity

Normal operation ensured in relative humidity range of 5% to 90%, noncondensing

Temperature

Normal operation ensured in temperature range of 0°C (32°F) to 40°C (104°F)

Non-operating storage temperature in shipping carton: –40°C (–40°F) to 70°C (158°F)

Seismic

Designed to meet Telcordia Technologies Zone 4 earthquake requirements

Maximum thermal output

  • J2320 chassis: 1091 BTU/hour (320 W)
  • J2350 chassis: 1195 BTU/hour (350 W)
  • J4350 chassis: 1092 BTU/hour (320 W)
  • J6350 chassis: 1126 BTU/hour (330 W)