[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]

max-time-report

Syntax

max-time-report value ;

Hierarchy Level

[edit security idp sensor-configuration log suppression]

Release Information

Statement introduced in Release 9.2 of JUNOS software.

Description

When log suppression is enabled, IDP maintains a count of multiple occurrences of the same event. After the specified number of seconds has passed, IDP writes a single log entry containing the count of occurrences.

This statement is supported on SRX-series devices.

Options

value —Time after which IDP writes a single log entry containing the count of occurrences.

Range: 1 through 60 seconds
Default: 10 seconds

Usage Guidelines

For configuration instructions and examples, see the JUNOS Software Security Configuration Guide.

Required Privilege Level

security—To view this statement in the configuration.

security-control—To add this statement to the configuration.


[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]