[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]

max-timers-poll-ticks

Syntax

max-timers-poll-ticks value ;

Hierarchy Level

[edit security idp sensor-configuration flow]

Release Information

Statement introduced in Release 9.2 of JUNOS software.

Description

Specify the time at which timer ticks at regular interval.

This statement is supported on SRX-series devices.

Options

value —Maximum amount of time at which the timer ticks.

Range: 0 through 1000 ticks
Default: 1000 ticks

Usage Guidelines

For configuration instructions and examples, see the JUNOS Software Security Configuration Guide.

Required Privilege Level

security—To view this statement in the configuration.

security-control—To add this statement to the configuration.


[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]