ACX5448, ACX5448-D, and ACX5448-M Management and Console Port Specifications and Pinouts
Management Cable Specifications for ACX5400 Routers
Table 1 lists the specifications for the cables that connect the console and management ports to management devices.
Ports |
Cable Specifications |
Receptacle |
Additional Information |
|---|---|---|---|
RJ-45 Console port |
CAT5e UTP (unshielded twisted pair) cable |
RJ-45 |
Connect a Device to a Management Console Using an RJ-45 Connector |
Management Ethernet port |
Ethernet cable with an RJ-45 connector |
RJ-45 |
Management Port Connector Pinout Information for ACX Series Routers
The management port— labeled MGMT— on an ACX Series router uses an RJ-45 connector to connect to a management device for out-of-band management.
The port uses an autosensing RJ-45 connector to support a 10/100BASE-T connection. Two LEDs indicate link activity on the port and the administrative status of the port.
Table 2 provides the pinout information for the RJ-45 connector for the management port.
Pin |
Description |
Direction |
|---|---|---|
1 |
TRD[0]- |
In/Out |
2 |
TRD[0]+ |
In/Out |
3 |
TRD[1]- |
In/Out |
4 |
TRD[1]+ |
In/Out |
5 |
TRD[2]- |
In/Out |
6 |
TRD[2]+ |
In/Out |
7 |
TRD[3]- |
In/Out |
8 |
TRD[3]+ |
In/Out |
Console Port Connector Pinout on ACX5400 Routers
The port labeled CON on the front panel is an asynchronous serial interface that accept an RJ-45 connector. Use a cable with the pinouts described in Table 3 to connect the Routing Engine to a console management device.
You must use a shielded twisted pair (STP) cable for both outdoor and indoor deployments.
Pin |
Signal |
Description |
CPU |
Direction |
|---|---|---|---|---|
3 |
TXD |
Transmit Data |
Routing Engine |
Out |
4 |
Ground |
Signal Ground |
– |
– |
5 |
Ground |
Signal Ground |
– |
– |
6 |
RXD |
Receive Data |
Routing Engine |
In |
USB Port Specifications for an ACX Series Router
All USB flash drives used on ACX Series routers must meet the following requirements:
USB 2.0 or later
Formatted with a FAT32 or MS-DOS file system