- play_arrow Fast Track: Initial Installation
- play_arrow Site Planning, Preparation, and Specifications
- play_arrow Preparation Overview
- play_arrow Transceiver and Cable Specifications
- play_arrow Pinout Specifications
- play_arrow AC Power Requirements, Specifications, and Guidelines
- play_arrow DC Power Requirements, Specifications, and Guidelines
- play_arrow High-Voltage Second-Generation Universal (HVAC or HVDC) Power Requirements, Specifications, and Guidelines
- Electrical Specifications for the MX960 High-Voltage Second-Generation Universal (HVAC/HVDC) Power Supply
- Power Requirements for an MX960 Router
- Calculating Power Requirements for MX960 Routers
- High-Voltage Second-Generation Universal (HVAC or HVDC) Power Circuit Breaker Requirements for the MX960 Router
- High-Voltage Second-Generation Universal (MX960-PSM-HV) Power Cord Specifications for the MX960 Router
-
- play_arrow Initial Installation and Configuration
- play_arrow Unpacking the MX960 Router
- play_arrow Installing the Mounting Hardware
- play_arrow Installing the MX960 Router
- Installing an MX960 Router Overview
- Removing Components from the MX960 Router Chassis Before Installing It with a Lift
- Tools Required to Install the MX960 Router with a Mechanical Lift
- Installing the MX960 Router Using a Mechanical Lift
- MX960 Acoustic Cover Installation Instructions
- MX960 Extended Cable Manager Installation Instructions
- Reinstalling Components in the MX960 Chassis After Installing It with a Lift
- play_arrow Connecting the MX960 Router to Power
- Tools and Parts Required for MX960 Router Grounding and Power Connections
- Grounding the MX960 Router
- Connecting Power to an AC-Powered MX960 Router with Normal-Capacity Power Supplies
- Connecting Power to an AC-Powered MX960 Router with High-Capacity Power Supplies
- Connecting Power to an AC-Powered MX960 Router with High-Capacity Second-Generation Power Supplies
- Powering On an AC-Powered MX960 Router with Normal Capacity Power Supplies
- Connecting Power to a DC-Powered MX960 Router with Normal-Capacity Power Supplies
- Connecting Power to a DC-Powered MX960 Router with High-Capacity Power Supplies
- Powering On a DC-Powered MX960 Router with Normal Capacity Power Supplies
- Connecting Power to an MX960 Router with High-Voltage Second-Generation Universal (HVAC or HVDC) Power Supplies
- Powering Off the MX960 Router
- Connecting an MX960 AC Power Supply Cord
- Connecting an MX960 DC Power Supply Cable
- play_arrow Connecting the MX960 Router to the Network
- Tools and Parts Required for MX960 Router Connections
- Connecting the MX960 Router to Management and Alarm Devices
- Connecting the MX960 Router to a Network for Out-of-Band Management
- Connecting the MX960 Router to a Management Console or Auxiliary Device
- Connecting an MX960 Router to an External Alarm-Reporting Device
- Connecting DPC, MPC, MIC, or PIC Cables to the MX960 Router
- Connecting the Alarm Relay Wires to the MX960 Craft Interface
- play_arrow Initially Configuring the MX960 Router
-
- play_arrow Installing and Replacing Components
- play_arrow Overview of Installing and Replacing Components
- play_arrow Installing Components
- Installing the MX960 Craft Interface
- Installing the MX960 Air Filter
- Installing an MX960 Fan Tray
- Installing an MX960 Routing Engine
- Installing an MX960 Switch Control Board
- Installing an MX960 DPC
- Installing an MX960 FPC
- Installing an MX960 MIC
- Installing an MX960 Dual-Wide MIC
- Installing an MX960 MPC
- Installing an MX960 PIC
- Installing a Cable on an MX960 DPC, MPC, MIC, or PIC
- Installing a MX960 AC Power Supply or High-Voltage Second-Generation Universal (HVAC or HVDC)
- Installing an MX960 DC Power Supply
- Installing an MX960 AS MLC
- Installing an MX960 AS MSC
- Installing an MX960 AS MXC
- Installing an SFP or XFP Transceiver into an MX960 DPC, MPC, MIC, or PIC
- Replacing a CFP2 Transceiver
- Replacing a CFP Transceiver
- play_arrow Replacing Chassis Components
- play_arrow Replacing Cooling System Component
- play_arrow Replacing Host Subsystem Components
- Replacing an MX960 Routing Engine
- Replacing an SSD Drive on an RE-S-1800
- Replacing an SSD Drive on an RE-S-X6-64G
- Replacing Connections to MX960 Routing Engine Interface Ports
- Upgrading to the RE-S-X6-64G Routing Engine in a Redundant Host Subsystem
- Upgrading to the RE-S-X6-64G Routing Engine in a Nonredundant Host Subsystem
- play_arrow Replacing Line Card Components
- play_arrow Replacing Power System Components
- play_arrow Replacing and Upgrading Switch Control Boards
-
- play_arrow Maintaining the Chassis and Components
- play_arrow Routine Maintenance Procedures
- play_arrow Maintaining Components
- Tools and Parts Required to Maintain the MX960 Router
- Maintaining the MX960 Air Filter
- Maintaining the MX960 Fan Trays
- Maintaining the MX960 Host Subsystem
- Maintaining MX960 DPCs
- Holding an MX960 DPC
- Storing an MX960 DPC
- Maintaining MX960 FPCs
- Holding an MX960 FPC
- Storing an MX960 FPC
- Maintaining MX960 MICs
- Maintaining MX960 MPCs
- Maintaining MX960 PICs
- Maintaining Cables That Connect to MX960 DPCs, MPCs, MICs, or PICs
- Maintaining MX-SPC3 Services Card
- Maintaining the MX960 Power Supplies
- Verifying the Version of the MX960 Cable Manager
- play_arrow Converting to a Different Type of Power Supply
-
- play_arrow Troubleshooting Hardware
- play_arrow Knowledge Base
- play_arrow Troubleshooting Components
-
- play_arrow Contacting Customer Support and Returning the Chassis or Components
- play_arrow Contacting Customer Support
- play_arrow Locating Component Serial Numbers
- Displaying MX960 Router Components and Serial Numbers
- MX960 Routing Engine Serial Number Label
- MX960 Chassis Serial Number and Agency Label
- MX960 Craft Interface Serial Number Label
- MX960 Fan Tray Serial Number Label
- MX960 Power Supply Serial Number Labels
- MX960 MIC Serial Number Label
- MX960 MPC Serial Number Label
- MX960 PIC Serial Number Label
- MX960 FPC Serial Number Label
- MX960 DPC Serial Number Label
- MX960 SCB Serial Number Label
- MX960 Midplane Serial Number Label
- Contact Customer Support
- play_arrow Packing and Returning Components
-
- play_arrow Safety and Compliance Information
- play_arrow General Safety Guidelines and Warnings
- play_arrow Installation and Maintenance Safety Guidelines and Warnings
- play_arrow Radiation and Laser Warnings
- play_arrow Maintenance and Operational Safety Guidelines and Warnings
- play_arrow Electrical Safety Guidelines and Warnings
- General Electrical Safety Guidelines and Warnings
- Prevention of Electrostatic Discharge Damage
- AC Power Electrical Safety Guidelines
- AC Power Disconnection Warning
- DC Power Copper Conductors Warning
- DC Power Disconnection Warning
- DC Power Grounding Requirements and Warning
- DC Power Wiring Sequence Warning
- DC Power Wiring Terminations Warning
- Midplane Energy Hazard Warning
- Multiple Power Supplies Disconnection Warning
- Action to Take After an Electrical Accident
- play_arrow Agency Approvals and Compliance Statements
- Agency Approvals for MX960 Routers
- Compliance Statements for NEBS for the MX960 Router
- Compliance Statements for EMC Requirements for the MX960 Router
- Compliance Statements for Environmental Requirements
- Compliance Statements for Acoustic Noise for the MX960 Router
- Statements of Volatility for Juniper Network Devices
-
MICs Supported by MX Series Routers
The following tables list the first supported Junos OS release for the MX Series.
Table 1 lists the first supported Junos OS release for MICs on MX240, MX480, MX960, and MX2008 routers.
Table 2 lists the first supported Junos OS release for MICs on MX2010 and MX2020 routers.
Table 3 list the first supported Junos OS release for MICs on MX5, MX10, and MX40 routers.
Table 4 lists the first supported Junos OS release for MICs on MX80 and MX104 routers.
Table 5 lists the first supported Junos OS release for MICs on MX10003 router.
MIC Name | MIC Model Number | Ports | MX240, MX480, and MX960 Routers | MX2008 Routers |
---|---|---|---|---|
ATM | ||||
MIC-3D-8OC3-2OC12-ATM | 8 | 12.1 | 15.1F7 | |
DS3/E3 | ||||
MIC-3D-8DS3-E3, MIC-3D-8CHDS3-E3-B | 8 | 11.4 | 15.1F7 | |
Circuit Emulation | ||||
MIC-3D-16CHE1-T1-CE | 16 | 12.3 | 15.1F7 | |
Gigabit Ethernet | ||||
MIC-3D-20GE-SFP | 20 | 10.1 | 15.1F7 | |
MIC-3D-20GE-SFP-E | 20 | 13.3 | 15.1F7 | |
MIC-MACSEC-20GE | 20 | 18.3 | — | |
10-Gigabit Ethernet | ||||
MIC-3D-2XGE-XFP | 2 | 10.2 | 15.1F7 | |
MIC-3D-4XGE-XFP | 4 | 10.1 | 15.1F7 | |
1-Gigabit/10-Gigabit Ethernet MIC with SFP+ (10 Ports) | MIC-3D-10GE-SFP-E | 10 | 24.2 | — |
MIC3-3D-10XGE-SFPP | 10 | 12.3 | 15.1F7 | |
MIC6-10G | 24 | — | 15.1F7 | |
MIC6-10G-OTN | 24 | — | 15.1F7 | |
40-Gigabit Ethernet | ||||
MIC3-3D-2X40GE-QSFPP | 2 | 12.2 | 15.1F7 | |
100-Gigabit Ethernet | ||||
MIC3-3D-1X100GE-CFP | 1 | 12.1 | 15.1F7 | |
MIC3-3D-1X100GE-CXP | 1 | 12.2 | 15.1F7 | |
MIC6-100G-CXP | 4 | — | 15.1F7 | |
MIC6-100G-CFP2 | 2 | — | 15.1F7 | |
100-Gigabit DWDM OTN | ||||
MIC3-100G-DWDM | 1 | 15.1F515.1F617.1R1 | 15.1F7 | |
Multi-Rate | ||||
MIC-3D-4OC3OC12-1OC48 | 4 | 11.2 | 15.1F7 | |
MIC-3D-8OC3OC12-4OC48 | 8 | 11.2 | 15.1F7 | |
MIC-3D-4CHOC3-2CHOC12 | 4 | 11.4 | 15.1F7 | |
MIC-3D-8CHOC3-4CHOC12 | 8 | 11.4 | 15.1F7 | |
Channelized OC3/STM1 (Multi-Rate) Circuit Emulation MIC with SFP | MIC-3D-4COC3-1COC12-CE | 4 | 12.2 | 15.1F7 |
MIC MRATE (12-Port Multi-Rate MIC with QSFP+) | MIC-MRATE | 12 | — | 15.1F7 |
Multi-Rate Ethernet MIC (12-Port Multi-Rate MACsec MIC with QSFP+) | MIC-MACSEC-MRATE | 12 | — | 17.4 |
Tri-Rate | ||||
MIC-3D-40GE-TX | 40 | 10.2 | 15.1F7 | |
Services | ||||
MS-MIC-16G | 0 | 13.2 | 15.1F7 | |
SONET/SDH | ||||
MIC-3D-1OC192-XFP | 1 | 12.2 | 15.1F7 |
MIC Name | MIC Model Number | Ports | MX2010 Routers | MX2020 Routers |
---|---|---|---|---|
ATM | ||||
MIC-3D-8OC3-2OC12-ATM | 8 | 12.3 | 12.3 | |
DS3/E3 | ||||
MIC-3D-8DS3-E3, MIC-3D-8CHDS3-E3-B | 8 | 12.3 | 12.3 | |
Circuit Emulation | ||||
MIC-3D-16CHE1-T1-CE | 16 | — | — | |
Gigabit Ethernet | ||||
MIC-3D-20GE-SFP | 20 | 12.3 | 12.3 | |
MIC-3D-20GE-SFP-E | 20 | 13.3 | 13.3 | |
10-Gigabit Ethernet | ||||
MIC-3D-2XGE-XFP | 2 | 12.3 | 12.3 | |
MIC-3D-4XGE-XFP | 4 | 12.3 | 12.3 | |
1-Gigabit/10-Gigabit Ethernet MIC with SFP+ (10 Ports) | MIC-3D-10GE-SFP-E | 10 | 24.2 | 24.2 |
MIC3-3D-10XGE-SFPP | 10 | 12.3 | 12.3 | |
MIC6-10G | 24 | 13.3R2 | 13.3R2 | |
MIC6-10G-OTN | 24 | 13.3R3 | 13.3R3 | |
40-Gigabit Ethernet | ||||
MIC3-3D-2X40GE-QSFPP | 2 | 12.3 | 12.3 | |
100-Gigabit Ethernet | ||||
MIC3-3D-1X100GE-CFP | 1 | 12.3 | 12.3 | |
MIC3-3D-1X100GE-CXP | 1 | 12.3 | 12.3 | |
MIC6-100G-CXP | 4 | 13.3R2 | 13.3R2 | |
MIC6-100G-CFP2 | 2 | 13.3R3 | 13.3R3 | |
100-Gigabit DWDM OTN | ||||
MIC3-100G-DWDM | 1 | 15.1F515.1F617.1R1 | 15.1F515.1F617.1R1 | |
Multi-Rate | ||||
MIC-3D-4OC3OC12-1OC48 | 4 | 12.3 | 12.3 | |
MIC-3D-8OC3OC12-4OC48 | 8 | 12.3 | 12.3 | |
MIC-3D-4CHOC3-2CHOC12 | 4 | 12.3 | 12.3 | |
MIC-3D-8CHOC3-4CHOC12 | 8 | 12.3 | 12.3 | |
Channelized OC3/STM1 (Multi-Rate) Circuit Emulation MIC with SFP | MIC-3D-4COC3-1COC12-CE | 4 | 12.3 | 12.3 |
MIC MRATE (12-Port Multi-Rate MIC with QSFP+) | MIC-MRATE | 12 | 15.1F5 with Junos Continuity 16.1R1 and later | 15.1F5 with Junos Continuity 16.1R1 and later |
Multi-Rate Ethernet MIC (12-Port Multi-Rate MACsec MIC with QSFP+) | MIC-MACSEC-MRATE | 12 | 17.4 | 17.4 |
Tri-Rate | ||||
MIC-3D-40GE-TX | 40 | 12.3 | 12.3 | |
Services | ||||
MS-MIC-16G | 0 | 13.2 | 13.2 | |
SONET/SDH | ||||
MIC-3D-1OC192-XFP | 1 | 12.3 | 12.3 |
MIC Name | MIC Model Number | Ports | MX5 | MX10 | MX40 |
---|---|---|---|---|---|
ATM | |||||
MIC-3D-8OC3-2OC12-ATM | 8 | 12.1 | 12.1 | 12.1 | |
DS3/E3 | |||||
MIC-3D-8DS3-E3, MIC-3D-8CHDS3-E3-B | 8 | 11.4 | 11.4 | 11.4 | |
Circuit Emulation | |||||
MIC-3D-16CHE1-T1-CE | 16 | 13.2R2 | 13.2R2 | 13.2R2 | |
MIC-3D-16CHE1-T1-CE-H | 16 | — | — | — | |
Gigabit Ethernet | |||||
MIC-3D-20GE-SFP | 20 | 11.2R4 | 11.2R4 | 11.2R4 | |
MIC-3D-20GE-SFP-E | 20 | 13.2R2 | 13.2R2 | 13.2R2 | |
MIC-3D-20GE-SFP-EH | 20 | — | — | — | |
10-Gigabit Ethernet | |||||
MIC-3D-2XGE-XFP | 2 | 11.2R4 | 11.2R4 | 11.2R4 | |
Multi-Rate | |||||
MIC-3D-4OC3OC12-1OC48 | 4 | 11.2R4 | 11.2R4 | 11.2R4 | |
MIC-3D-8OC3OC12-4OC48 | 8 | 11.2R4 | 11.2R4 | 11.2R4 | |
MIC-3D-4CHOC3-2CHOC12 | 4 | 11.4 | 11.4 | 11.4 | |
MIC-3D-8CHOC3-4CHOC12 | 8 | 11.4 | 11.4 | 11.4 | |
Channelized OC3/STM1 (Multi-Rate) Circuit Emulation MIC with SFP | MIC-3D-4COC3-1COC12-CE | 4 | 12.2 | 12.2 | 12.2 |
Channelized OC3/STM1 (Multi-Rate) Circuit Emulation MIC with SFP (H) | MIC-4COC3-1COC12-CE-H | — | — | — | — |
Tri-Rate | |||||
MIC-3D-40GE-TX | 40 | — | 11.2R4 | 11.2R4 | |
Services | |||||
MS-MIC-16G | 0 | 13.2 Rear slot only. | 13.2 Rear slot only. | 13.2 Rear slot only. | |
MIC-3D-1OC192-XFP | 1 | 12.2 | 12.2 | 12.2 |
MIC Name | MIC Model Number | Ports | MX80 | MX104 |
---|---|---|---|---|
ATM | ||||
MIC-3D-8OC3-2OC12-ATM | 8 | 12.1 | 13.3 | |
DS3/E3 | ||||
MIC-3D-8DS3-E3, MIC-3D-8CHDS3-E3-B | 8 | 11.4 | 13.3 | |
Circuit Emulation | ||||
MIC-3D-16CHE1-T1-CE | 16 | 13.2R2 | 13.2R2 | |
MIC-3D-16CHE1-T1-CE-H | 16 | — | 13.2R2 | |
Gigabit Ethernet | ||||
MIC-3D-20GE-SFP | 20 | 10.2 | 13.2R2 | |
MIC-3D-20GE-SFP-E | 20 | 13.2R2 | 13.2R2 | |
MIC-3D-20GE-SFP-EH | 20 | — | 13.2R2 | |
MIC-MACSEC-20GE | 20 | 18.3 | 18.3 | |
MIC-3D-2XGE-XFP | 2 | 10.2 | 13.2R2 | |
Multi-Rate | ||||
MIC-3D-4OC3OC12-1OC48 | 4 | 11.2 | 13.3 | |
MIC-3D-8OC3OC12-4OC48 | 8 | 11.2 | 13.3 | |
MIC-3D-4CHOC3-2CHOC12 | 4 | 11.4 | 13.3 | |
MIC-3D-8CHOC3-4CHOC12 | 8 | 11.4 | 13.3 | |
Channelized OC3/STM1 (Multi-Rate) Circuit Emulation MIC with SFP | MIC-3D-4COC3-1COC12-CE | 4 | 12.2 | 13.2R2 |
Channelized OC3/STM1 (Multi-Rate) Circuit Emulation MIC with SFP (H) | MIC-4COC3-1COC12-CE-H | — | — | 13.2R2 |
Tri-Rate | ||||
MIC-3D-40GE-TX | 40 | 10.2 | 13.2R2 | |
Services | ||||
MS-MIC-16G | 0 | 13.2 Rear slot only. Supported on the modular MX80 and fixed MX80-48T | 13.3R2 Note: Starting From Junos OS 13.3R3, 14.1R2, and 14.2R1, MX104 supports only two Multiservices MICs. | |
SONET/SDH | ||||
MIC-3D-1OC192-XFP | 1 | 12.2 | 13.3 |
MIC Name | MIC Model Number | Ports | MX10003 |
---|---|---|---|
Multi-Rate | |||
Multi-Rate Ethernet MIC (12-Port Multi-Rate MIC with QSFP+) | JNP-MIC1 | 12 | 17.3 |
Multi-Rate Ethernet MIC (12-Port Multi-Rate MACsec MIC with QSFP+) | JNP-MIC1-MACSEC | 12 | 17.3R2 |