ON THIS PAGE
Pluggable Transceivers and Direct Attach Cables Supported on QFX5120 Switches
Cable Specifications for QSFP+ and QSFP28 Transceivers on QFX5120 Switches
How to Calculate the Fiber-Optic Cable Power Budget for QFX Series Switches
How to Calculate the Fiber-Optic Cable Power Margin for QFX Series Switches
QFX5120 Network Cable and Transceiver Planning
Pluggable Transceivers and Direct Attach Cables Supported on QFX5120 Switches
QFX5120 switches support SFP, SFP+, SFP28, QSFP+, and QSFP28 transceivers. They also support direct attach cables. You can find the list of transceivers supported on QFX5120 switches and information about those transceivers at the following pages:
QFX5120-32C—Hardware Compatibility Tool page for QFX5120-32C
QFX5120-48T—Hardware Compatibility Tool page for QFX5120-48T
QFX5120-48Y—Hardware Compatibility Tool page for QFX5120-48Y
QFX5120-48YM—Hardware Compatibility Tool page for QFX5120-48YM
We recommend that you use only optical transceivers and optical connectors purchased from Juniper Networks with your Juniper Networks device.
The Juniper Networks Technical Assistance Center (JTAC) provides complete support for Juniper-supplied optical modules and cables. However, JTAC does not provide support for third-party optical modules and cables that are not qualified or supplied by Juniper Networks. If you face a problem running a Juniper device that uses third-party optical modules or cables, JTAC may help you diagnose host-related issues if the observed issue is not, in the opinion of JTAC, related to the use of the third-party optical modules or cables. Your JTAC engineer will likely request that you check the third-party optical module or cable and, if required, replace it with an equivalent Juniper-qualified component.
Use of third-party optical modules with high-power consumption (for example, coherent ZR or ZR+) can potentially cause thermal damage to or reduce the lifespan of the host equipment. Any damage to the host equipment due to the use of third-party optical modules or cables is the users’ responsibility. Juniper Networks will accept no liability for any damage caused due to such use.
The Gigabit Ethernet transceivers installed in QFX5120 switches
support digital optical monitoring (DOM): You can view the diagnostic
details for these transceivers by issuing the operational mode CLI
command show interfaces diagnostics
.
Cable Specifications for QSFP+ and QSFP28 Transceivers on QFX5120 Switches
The 40GbE QSFP+ and 100GbE QSFP28 transceivers used in QFX5120 switches use 12-ribbon multimode fiber crossover cables with MPO/UP, MPO/UPC, or MPO/APC socket connectors. The fiber can be either OM3 or OM4. We do not sell these cables.
To maintain agency approvals, use only a properly constructed, shielded cable.
Ensure that you order cables with the correct polarity. Vendors refer to these crossover cables as key up to key up, latch up to latch up, Type B, or Method B. If you are using patch panels between two QSFP+ ports, ensure that the proper polarity is maintained through the cable plant.
Table 1 describes the signals on each fiber. Table 2 shows the pin-to-pin connections for proper polarity.
Fiber |
Signal |
---|---|
1 |
Tx0 (Transmit) |
2 |
Tx1 (Transmit) |
3 |
Tx2 (Transmit) |
4 |
Tx3 (Transmit) |
5 |
Unused |
6 |
Unused |
7 |
Unused |
8 |
Unused |
9 |
Rx3 (Receive) |
10 |
Rx2 (Receive) |
11 |
Rx1 (Receive) |
12 |
Rx0 (Receive) |
Pin |
Pin |
---|---|
1 |
12 |
2 |
11 |
3 |
10 |
4 |
9 |
5 |
8 |
6 |
7 |
7 |
6 |
8 |
5 |
9 |
4 |
10 |
3 |
11 |
2 |
12 |
1 |
How to Calculate the Fiber-Optic Cable Power Budget for QFX Series Switches
Calculate the fiber-optic data link's power budget when planning fiber-optic cable layout and distances to ensure that fiber-optic connections have sufficient power for correct operation. The power budget is the maximum amount of power the link can transmit. When you calculate the power budget, you use a worst-case analysis to provide a margin of error, even though all the parts of an actual system do not operate at the worst-case levels.
To calculate the worst-case estimate for the fiber-optic cable power budget (PB) for the link:
How to Calculate the Fiber-Optic Cable Power Margin for QFX Series Switches
Before you calculate the power margin, calculate the power budget. See How to Calculate the Fiber-Optic Cable Power Budget for QFX Series Switches.
Calculate the fiber-optic data link's power margin when planning fiber-optic cable layout and distances to ensure that fiber-optic connections have sufficient signal power to overcome system losses and still satisfy the minimum input requirements of the receiver for the required performance level. The power margin (PM ) is the amount of power available after attenuation or link loss (LL) is subtracted from the power budget (PB).
When you calculate the power margin, you use a worst-case analysis to provide a margin of error, even though all the parts of an actual system do not operate at worst-case levels. A power margin (PM ) greater than zero indicates that the power budget is sufficient to operate the receiver and that it does not exceed the maximum receiver input power. This means the link will work. A power margin (PM) that is zero or negative indicates insufficient power to operate the receiver. See the specification for your receiver to find the maximum receiver input power.
To calculate the worst-case estimate for the power margin (PM) for the link: