Before you begin connecting DC power to the device:
Ensure that you have taken the necessary precautions to prevent electrostatic discharge (ESD) damage (see Prevention of Electrostatic Discharge Damage).
Ensure that you have connected the device chassis to earth ground.
CAUTION:Before you connect power to the device, a licensed electrician must attach a cable lug to the grounding and power cables that you supply. A cable with an incorrectly attached lug can damage the device (for example, by causing a short circuit).
To meet safety and electromagnetic interference (EMI) requirements and to ensure proper operation, you must connect the chassis to earth ground before you connect it to power. For installations that require a separate grounding conductor to the chassis, use the protective earthing terminal on the device chassis to connect to the earth ground. For instructions on connecting earth ground, see Connecting Earth Ground to a QFX3500 Device or Connecting Earth Ground to QFX3600 or QFX3600-I Devices.
Install the power supply in the chassis. For instructions on installing a power supply in a QFX3500 device, see Installing a Power Supply in a QFX3500 Device. For instructions on installing a power supply in a QFX3600 or QFX3600-I device, see Installing a Power Supply in a QFX3600 or QFX3600-I Device
Ensure that you have the following parts and tools available:
DC power source cables (14–16 AWG) with ring lug (Molex 190700069 or equivalent) (not provided)
Phillips (+) screwdriver, number 2 (not provided)
Multimeter (not provided)
The QFX3500, QFX3600, and QFX3600-I devices are shipped from the factory with two 650 W power supplies pre-installed. Each power supply is a hot-removable and hot-insertable field-replaceable unit (FRU) when the second power supply is installed and running. You can install replacement power supplies without powering off the device or disrupting the switching function.
DC-powered QFX3500, QFX3600 and QFX3600-I devices are intended for installation only in a restricted access location.
The battery returns of the DC power supply should be connected as an isolated DC return (DC-I).
To connect DC power to a QFX3500, QFX3600 or QFX3600-I device: