Configuring RPM Receiver Servers
The RPM TCP and UDP probes are proprietary to Juniper Networks and require a receiver
to receive the probes. To configure a server to receive the probes, include the
probe-server
statement at the [edit services
rpm]
hierarchy
level for Junos OS
or the [edit services monitoring rpm]
hierarchy level for Junos OS
Evolved:
[edit services rpm] probe-server { tcp { destination-interface interface-name; port number; } udp { port number; } }
The port number specified for the UDP and TCP server can be 7
or
from 49160
through 65535
.
The destination-interface
statement is not supported on PTX
Series Packet Transport
routers, or
for devices running Junos OS Evolved.
When
you configure either probe-type udp-ping
or probe-type
udp-ping-timestamp
along with the
one-way-hardware-timestamp
command, the value for the
destination-port
can be only 7. A constraint check prevents you
for configuring any other value for the destination port in this case.