Supported Platforms
show interfaces ps0 (Pseudowire Subscriber Interfaces)
Syntax
Release Information
Command introduced at Junos OS Release 13.1.
Description
Display status information about the pseudowire subscriber interface.
Options
brief | detail | extensive | terse | — | (Optional) Display the specified level of output. |
Required Privilege Level
view
List of Sample Output
show interfaces ps0Output Fields
Table 1 lists the output fields for the show interfaces ps0 command. Output fields are listed in the approximate order in which they appear.
Table 1: show interfaces ps0 Output Fields
Field Name | Field Description | Level of Output |
---|---|---|
Physical Interface | ||
Physical interface | Name of the physical interface. | brief detail extensive none |
Enabled | State of the interface. Possible values are described in the “Enabled Field” section under Common Output Fields Description. | brief detail extensive none |
Interface index | Physical interface index number, which reflects its initialization sequence. | detail extensive none |
SNMP ifIndex | SNMP index number for the physical interface. | detail extensive none |
Type | Physical interface type (Software-Pseudo). | brief detail extensive none |
Link-level type | Encapsulation being used on the physical interface. | brief detail extensive |
MTU | MTU size on the physical interface. | brief detail extensive |
Clocking | Reference clock source. It can be Internal or External. | brief detail extensive |
Speed | Speed at which the interface is running. | brief detail extensive |
Device flags | Information about the physical device. Possible values are described in the “Device Flags” section under Common Output Fields Description. | brief detail extensive none |
Interface flags | Information about the interface. Possible values are described in the “Interface Flags” section under Common Output Fields Description. | brief detail extensive none |
Current address | Configured MAC address. | detail extensive none |
Hardware address | MAC address of the hardware. | detail extensive none |
Last flapped | Date, time, and how long ago the interface went from down to up or up to down. The format is Last flapped: year-month-day hours:minutes:seconds: timezone (hours:minutes:seconds ago). or Never. For example, Last flapped: 2002-04-26 10:52:40 PDT (04:33:20 ago). | detail extensive none |
input packets | Number of packets received on the logical interface. | detail extensive none |
output packets | Number of packets transmitted on the logical interface. | detail extensive none |
Logical Interface | ||
Logical interface | Name of the logical interface. | brief detail extensive none |
Index | Logical interface index number (which reflects its initialization sequence). | detail extensive none |
SNMP ifIndex | Logical interface SNMP interface index number. | detail extensive none |
Flags | Information about the logical interface. Possible values are described in the “Logical Interface Flags” section under Common Output Fields Description. | brief detail extensive none |
Encapsulation | Type of encapsulation configured on the logical interface. | brief extensive none |
Input packets | Number of packets received on the logical interface. | none |
Output packets | Number of packets transmitted on the logical interface. | none |
Protocol | Protocol family configured on the logical interface. | detail extensive none |
MTU | MTU size on the logical interface. | detail extensive none |
Flags | Information about the protocol family flags. Possible values are described in the “Family Flags” section under Common Output Fields Description. | detail extensive none |
Addresses, Flags | Information about the addresses configured for the protocol family. Possible values are described in the “Addresses Flags” section under Common Output Fields Description. | detail extensive none |
Destination | IP address of the remote side of the connection. | detail extensive none |
Local | IP address of the logical interface. | detail extensive terse none |
Broadcast | Broadcast address. | detail extensive none |
Sample Output
show interfaces ps0
user@host> show interfaces ps0
Physical interface: ps0, Enabled, Physical link is Up Interface index: 166, SNMP ifIndex: 658 Type: Software-Pseudo, Link-level type: 90, MTU: 1518, Clocking: 1, Speed: 800mbps Device flags : Present Running Interface flags: Point-To-Point Internal: 0x4000 Current address: 00:1d:b5:a8:19:4a, Hardware address: 00:1d:b5:a8:19:4a Last flapped : Never Input packets : 0 Output packets: 0 Logical interface ps0.0 (Index 74) (SNMP ifIndex 656) Flags: Point-To-Point 0x4000 Encapsulation: Ethernet-CCC Input packets : 482 Output packets: 0 Protocol ccc, MTU: 1518 Flags: Is-Primary Logical interface ps0.1 (Index 78) (SNMP ifIndex 665) Flags: Point-To-Point 0x4000 VLAN-Tag [ 0x8100.100 ] Encapsulation: ENET2 Input packets : 0 Output packets: 482 Protocol inet, MTU: 1500 Flags: Sendbcast-pkt-to-re Addresses, Flags: Is-Preferred Is-Primary Destination: 20.0.0/24, Local: 20.0.0.1, Broadcast: 20.0.0.255 Logical interface ps0.32767 (Index 75) (SNMP ifIndex 692) Flags: Point-To-Point 0x4000 VLAN-Tag [ 0x0000.0 ] Encapsulation: ENET2 Input packets : 0 Output packets: 0