[an error occurred while processing this directive] [an error occurred while processing this directive]

Configuring a Virtual Chassis (J-Web Procedure)

To take advantage of the scalability features of EX4200 switches, you can configure a Virtual Chassis that includes up to 10 member switches. You can interconnect the member switches using the dedicated Virtual Chassis ports (VCPs) on the back of the switch. You do not have to configure the interface for the dedicated VCPs. If you want to interconnect member switches that are located in different racks or wiring closets, interconnect them using uplinks configured as VCP interfaces. See Setting an Uplink Module Port as a Virtual Chassis Port (CLI Procedure).

To configure a Virtual Chassis using the J-Web interface:

  1. From the Configure menu, select the option Virtual Chassis.

    Note: The Virtual Chassis option is not available for EX3200 switches.

  2. The properties you can configure are displayed .

    The first section of the Virtual Chassis configuration page displays the Virtual Chassis member configuration. the display includes a list of member switches, their member IDs, and the mastership priority.

    The second section displays the operational status of the Virtual Chassis configuration, member details, and the dedicated and configured Virtual Chassis ports (VCPs).

  3. Enter information into the page as described in Table 1.
  4. Click one:
    • Add — To add a member's configuration to the Virtual Chassis configuration, click Add.
    • Edit — To modify an existing member's configuration, click Edit.
    • Delete — To delete the configuration of a member, click Delete.
  5. To configure an uplink as a VCP, select the member in the Virtual Chassis members list and select Action > Select Uplink Port as VCP. Select the port from the list.
  6. To delete an uplink VCP from a member, select the member in the Virtual Chassis members list and select Action > Delete Uplink Port as VCP.

Table 1: Virtual Chassis Configuration Fields

Field

Function

Your Action

Member Details

Member ID

Specifies the identifier for the member switch. The master switch assigns member IDs.

Select an identifier from the list. Select an ID from 0 through 9.

Priority

Specifies the mastership priority to be assigned to the member.

Select a number from 1 through 255, with 255 being the highest priority (128 is the default).

Disable Management VLAN

If you want to reserve an individual member's management Ethernet port for local troubleshooting, you can remove that port from being part of the Virtual Management Ethernet (VME).

Click to disable management VLAN on the port.

Refresh

Refreshes the operational status of Virtual Chassis members.

Click to refresh the operational status.


Published: 2009-07-29