Display Current SIB Alarms

Purpose

To determine the details of the current SIB alarms.

Action

Table 1 lists the SIB alarms that display in the craft interface LCD display and at the command line. For conditions that trigger SIB alarms, see Display the Current Router Alarms.

Table 1: SIB Alarm Messages

Component

LCD Short Version

CLI Long Version

SIB

SIB sib-number Failure

RED ALARM—SIB sib-number Fault

 

SIB sib-number Removed

RED ALARM—SIB sib-number Absent

 

Spare SIB Failure

YELLOW ALARM—Spare SIB Fault

 

Spare SIB Removed

YELLOW ALARM—Spare SIB Absent

 

Check SIB

YELLOW ALARM—Check SIB

To display the SIB environmental information, use the following command:

user@host>show chassis alarms

Sample Output

t640@host>  show chassis alarms
1alarms currently active
Alarm time                    Class     Description
2004-01-29 18:37:09 PST       Minor     SIB 2 Not Online

Meaning

The command output displays the alarm date, time, severity level, and description

 