Installing a WXC ISM 200
You can install a single WXC ISM 200 in either regular or high-speed
slots of a J2320, J2350, J4350, or J6350 Services Router. The module
occupies two slots, and the extra connector on high-speed slots is
detected and configured automatically. If you insert a second WXC
ISM 200, the module in the higher slot numbers will not power on.
 |
Caution:
Do not hot-swap WXC Integrated Services Modules or PIMs. Failure to power off
the router before removing or installing a module might result in
damage to the hardware.
|
To install a WXC ISM 200 (see Figure 5):
Figure 5: Installing a WXC Integrated Services Module

- Attach an electrostatic discharge (ESD) grounding
strap to your bare wrist and connect the strap to the ESD point on
the chassis, or to an outside ESD point if the Services Router is disconnected
from earth ground. For more information about ESD, see the JUNOS Software with Enhanced Services Hardware Guide.
- Back up the current router configuration.
- To power off the router, use the CLI command request system power-off (recommended), or hold down the power
button for at least 2 seconds. Verify that the POWER LED
blinks and then turns off.
- Remove the faceplates from two of the slots.
- Align the notches in the connector at the rear
of the WXC ISM 200 with the notches in the Services Router slot, and
slide the module in until it lodges firmly in the router.
 |
Caution:
Slide the WXC ISM 200 straight into the slot to avoid damaging
the components on the module.
|
- Tighten the screws on each side of the module faceplate.
- Press and release the power button to power on
the router. Verify that the POWER LED for the J-series Services Router lights
steadily after you press the power button.
- Verify that the ONLINE LED on the module
lights steadily green.
You can also verify the module is online by issuing the show chassis fpc pic-status command:
user@host> show chassis fpc pic-status
Slot 0 Online FPC
PIC 0 Online 4x GE Base PIC
Slot 2 Online FPC
PIC 0 Online Integrated Services Module
 |
Note:
In show chassis fpc-pic-status output, the higher of the two slot numbers occupied by the WXC ISM
200 is reported as an FPC number, and the PIC number is always zero.
|
For more information about show chassis fpc pic-status, see the JUNOS System Basics and Services Command Reference.
- Complete the initial configuration of the WXC ISM
200, as described in Configuring a WXC Integrated Services Module.
[