- play_arrow Fast Track: Initial Installation
- play_arrow Overview
- play_arrow Site Planning, Preparation, and Specifications
- play_arrow Initial Installation and Configuration
- play_arrow Maintaining Components
- play_arrow Troubleshooting Hardware
- play_arrow Safety and Compliance Information
- General Safety Guidelines and Warnings
- Definitions of Safety Warning Levels
- Qualified Personnel Warning
- Warning Statement for Norway and Sweden
- Fire Safety Requirements
- Installation Instructions Warning
- Chassis and Component Lifting Guidelines
- Restricted Access Warning
- Ramp Warning
- Rack-Mounting and Cabinet-Mounting Warnings
- Grounded Equipment Warning
- Laser and LED Safety Guidelines and Warnings
- Radiation from Open Port Apertures Warning
- Maintenance and Operational Safety Guidelines and Warnings
- General Electrical Safety Guidelines and Warnings
- Action to Take After an Electrical Accident
- Prevention of Electrostatic Discharge Damage
- AC Power Electrical Safety Guidelines
- AC Power Disconnection Warning
- DC Power Electrical Safety Guidelines
- DC Power Copper Conductors Warning
- DC Power Disconnection Warning
- DC Power Grounding Requirements and Warning
- DC Power Wiring Sequence Warning
- DC Power Wiring Terminations Warning
- Multiple Power Supplies Disconnection Warning
- TN Power Warning
- Agency Approvals and Compliance Statements for the QFX5200 and QFX5220
Returning the QFX5200 Chassis or Components
Locating the Serial Number on a QFX5200 Device or Component
If you are returning a switch or component to Juniper Networks for repair or replacement, you must locate the serial number of the switch or component. You must provide the serial number to the Juniper Networks Technical Assistance Center (JTAC) when you contact them to obtain a Return Materials Authorization (RMA).
If the switch is operational and you can access the command-line interface (CLI), you can list serial numbers for the switch and for some components with a CLI command. If you do not have access to the CLI or if the serial number for the component does not appear in the command output, you can locate the serial number ID label on the switch or component.
If you want to find the serial number ID label on a component, you need to remove the component from the switch chassis, for which you must have the required parts and tools available.
- Listing the Chassis and Component Details Using the CLI
- Locating the Chassis Serial Number ID Label on a QFX5200
- Locating the Serial Number ID Labels on FRU Components
Listing the Chassis and Component Details Using the CLI
To list the QFX5200 switch and components and their serial numbers,
use the show chassis hardware
CLI operational mode command.
The following examples shows the output for the QFX5200-32C models.
user@device> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis WH3615220019 Qfx5200-32c-32q Pseudo CB 0 Routing Engine 0 BUILTIN BUILTIN QFX Routing Engine FPC 0 650-059719 WH3615220019 Qfx5200-32c-32q CPU BUILTIN BUILTIN FPC CPU PIC 0 BUILTIN BUILTIN 32X40G/32X100G-QSFP Xcvr 0 REV 740-038623 APF15200013GBR QSFP+-40G-CU1M Xcvr 1 REV 01 740-032986 QC350639 QSFP+-40G-SR4 Xcvr 2 REV 01 740-038624 MOC12526240244 QSFP+-40G-CU3M Xcvr 3 REV 01 740-038624 MOC12286240027 QSFP+-40G-CU3M Xcvr 4 REV 740-044512 APF151500097D5 QSFP+-40G-CU50CM Xcvr 5 REV 01 740-038623 MOC12526230201 QSFP+-40G-CU1M Xcvr 6 REV 740-044512 APF151500097DT QSFP+-40G-CU50CM Xcvr 7 REV 740-044512 APF151500097DK QSFP+-40G-CU50CM Xcvr 8 REV 01 740-038623 MOC12526230104 QSFP+-40G-CU1M Xcvr 9 REV 01 740-038623 MOC13016230274 QSFP+-40G-CU1M Xcvr 10 REV 01 740-038623 MOC13016230255 QSFP+-40G-CU1M Xcvr 11 REV 01 740-038623 MOC13016230234 QSFP+-40G-CU1M Xcvr 12 REV 740-044512 APF151500097CW QSFP+-40G-CU50CM Xcvr 13 REV 740-044512 APF151500097D3 QSFP+-40G-CU50CM Xcvr 14 REV 740-044512 APF151500097DD QSFP+-40G-CU50CM Xcvr 15 REV 740-038623 APF15200013GAK QSFP+-40G-CU1M Xcvr 16 REV 740-038623 APF15200013GA5 QSFP+-40G-CU1M Xcvr 17 REV 740-038623 APF15200013GA9 QSFP+-40G-CU1M Xcvr 18 REV 740-038623 APF15200013GBK QSFP+-40G-CU1M Xcvr 19 REV 740-038623 APF15200013GBH QSFP+-40G-CU1M Xcvr 20 REV 01 740-038624 MOC12526240172 QSFP+-40G-CU3M Xcvr 21 REV 01 740-032986 QE483777 QSFP+-40G-SR4 Xcvr 22 REV 740-038623 APF15200013GAP QSFP+-40G-CU1M Xcvr 23 REV 740-038623 APF15200013GBC QSFP+-40G-CU1M Xcvr 24 REV 740-044512 APF151500097DP QSFP+-40G-CU50CM Xcvr 26 REV 01 740-053203 APF15050073YLU QSFP+-40G-ACU7M Xcvr 27 REV 740-038623 APF15200013GAU QSFP+-40G-CU1M Xcvr 28 REV 01 740-052307 APF14370078AJ2 QSFP+-40G-ACU7M Xcvr 29 REV 01 740-052307 APF14370078APW QSFP+-40G-ACU7M Xcvr 30 REV 01 740-032986 QE481024 QSFP+-40G-SR4 Xcvr 31 REV 01 740-032986 QD449842 QSFP+-40G-SR4 Fan Tray 0 fan-ctrl-2 0, Front to Back Airflow - AFO Fan Tray 1 fan-ctrl-2 1, Front to Back Airflow - AFO Fan Tray 2 fan-ctrl-2 2, Front to Back Airflow - AFO Fan Tray 3 fan-ctrl-2 3, Front to Back Airflow - AFO Fan Tray 4 fan-ctrl-2 4, Front to Back Airflow - AFO {master:0}
The next example shows the output from the QFX5200-32C-L models.
user@device> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis WN0218310472 QFX5200-32C-L PSM 0 REV 05 740-053352 1GD18230909 JPSU-850W-AC-AFO PSM 1 REV 05 740-053352 1GD18230901 JPSU-850W-AC-AFO Routing Engine 0 BUILTIN BUILTIN RE-QFX5200-32C-32Q CB 0 REV 02 650-088479 WN0218310472 QFX5200-32C-CHAS FPC 0 BUILTIN BUILTIN QFX5200-32C-32Q PIC 0 BUILTIN BUILTIN 32X40G/32X100G-QSFP Xcvr 0 REV 01 740-058734 1ACQ130900E QSFP-100GBASE-SR4 Xcvr 1 REVÿ01 740-038624 APF15170031W72 QSFP+-40G-CU3M Xcvr 2 REVÿ01 740-038625 APF165100537Y2 QSFP+-40G-CU5M Xcvr 3 REVÿ01 740-038625 APF165100538UE QSFP+-40G-CU5M Xcvr 4 REVÿ01 740-038625 APF165100538AB QSFP+-40G-CU5M Xcvr 5 REVÿ01 740-038624 APF1515003985L QSFP+-40G-CU3M Xcvr 6 REV 01 740-032986 QF3608R5 QSFP+-40G-SR4 Xcvr 7 REV 01 740-046565 QG1502LM QSFP+-40G-SR4 Xcvr 8 REV 01 740-032986 QB500134 QSFP+-40G-SR4 Xcvr 9 REV 01 740-067442 QI110561 QSFP+-40G-SR4 Xcvr 10 REV 01 740-032986 QB341588 QSFP+-40G-SR4 Xcvr 11 REVÿ01 740-038624 APF151500398DK QSFP+-40G-CU3M Xcvr 12 REV 01 740-058734 1ACQ110401G QSFP-100GBASE-SR4 Xcvr 13 REVÿ01 740-038624 APF15150039844 QSFP+-40G-CU3M Xcvr 14 REV 01 740-058734 1ACQ104202B QSFP-100GBASE-SR4 Xcvr 15 REV 01 740-061405 1ACQ13140NX QSFP-100GBASE-SR4 Xcvr 16 REV 01 740-032986 QF4900G4 QSFP+-40G-SR4 Xcvr 17 REVÿ01 740-038624 APF15150039889 QSFP+-40G-CU3M Xcvr 18 REV 01 740-046565 QF33003P QSFP+-40G-SR4 Xcvr 19 REV 01 740-052665 QH5002AK QSFP+-40G-SR4 Xcvr 20 REV 01 740-032986 QD477662 QSFP+-40G-SR4 Xcvr 21 REV 01 740-067442 QI1200SR QSFP+-40G-SR4 Xcvr 22 REV 01 740-061405 1ECQ11200A9 QSFP-100GBASE-SR4 Xcvr 23 REV 01 740-061405 1ACQ131416W QSFP-100GBASE-SR4 Xcvr 24 REV 01 740-061405 1ACQ131417A QSFP-100GBASE-SR4 Xcvr 25 REV 01 740-061405 1ACQ131417W QSFP-100GBASE-SR4 Xcvr 26 REV 01 740-061405 1ECQ1044045 QSFP-100GBASE-SR4 Xcvr 27 REV 01 740-058734 1ACQ111308Y QSFP-100GBASE-SR4 Xcvr 28 REV 01 740-058734 1ACQ1305019 QSFP-100GBASE-SR4 Xcvr 29 REV 01 740-052665 QH5002CM QSFP+-40G-SR4 Xcvr 30 REV 01 740-052665 QH5002D0 QSFP+-40G-SR4 Xcvr 31 REV 01 740-058734 1ECQ11210G1 QSFP-100GBASE-SR4 Fan Tray 0 QFX5200 Fan Tray Fan Tray 1 QFX5200 Fan Tray Fan Tray 2 QFX5200 Fan Tray Fan Tray 3 QFX5200 Fan Tray Fan Tray 4 QFX5200 Fan Tray user@device
You must remove the fan module to read the fan serial number from the serial number ID label. The fan module serial number cannot be viewed through the CLI. Fan Tray 2 refers to the third module from the left, counting from 0.
Locating the Chassis Serial Number ID Label on a QFX5200
The location for the chassis serial number ID label is located on the right side of the QFX5200-32C and QFX5200-32C-L port panel. See Figure 1 for an example of where to find the serial number ID.

The serial number is also available in the output of the show chassis hardware
operational mode CLI command.
Locating the Serial Number ID Labels on FRU Components
The power supplies and fan modules installed in a QFX5200 are field-replaceable units (FRUs). For each FRU, you must remove the FRU from the switch chassis to see the FRU serial number ID label.
AC power supply—The serial number ID label is on the top of the AC power supply.
Fan module—The serial number ID label is on the top of the fan module.
How to Return a Hardware Component to Juniper Networks, Inc.
If a hardware component fails, please contact Juniper Networks, Inc. to obtain a Return Material Authorization (RMA) number. This number is used to track the returned material at the factory and to return repaired or new components to the customer as needed.
Do not return any component to Juniper Networks, Inc. unless you have first obtained an RMA number. Juniper Networks, Inc. reserves the right to refuse shipments that do not have an RMA. Refused shipments are returned to the customer by collect freight.
For more information about return and repair policies, see the customer support webpage at https://support.juniper.net/support/.
For product problems or technical support issues, contact the Juniper Networks Technical Assistance Center (JTAC) by using the Service Request Manager link at https://support.juniper.net/support/ or at 1-888-314-JTAC (within the United States) or 1-408-745-9500 (from outside the United States).
To return a defective hardware component:
Guidelines for Packing Hardware Components for Shipment
To pack and ship individual components:
When you return components, make sure that they are adequately protected with packing materials and packed so that the pieces are prevented from moving around inside the carton.
Use the original shipping materials if they are available.
Place individual components in antistatic bags.
Write the RMA number on the exterior of the box to ensure proper tracking.
Do not stack any of the hardware components.
Packing a QFX5200 Device or Component for Shipping
If you are returning a QFX5200 or component to Juniper Networks for repair or replacement, pack the item as described in this topic.
Before you pack a QFX5200 or component:
Ensure that you have taken the necessary precautions to prevent electrostatic discharge (ESD) damage. See Prevention of Electrostatic Discharge Damage.
Retrieve the original shipping carton and packing materials. Contact your JTAC representative if you do not have these materials, to learn about approved packing materials. See Contacting Customer Support to Obtain a Return Materials Authorization for a QFX Series Device or Component.
Ensure that you have the following parts and tools available:
ESD grounding strap.
Antistatic bag, one for each component.
If you are returning the chassis, an appropriate screwdriver for the mounting screws used on your rack or cabinet.
This topic describes:
Packing a QFX5200 Switch for Shipping
To pack a QFX5200 for shipping:
- Power down the switch and remove the power cables. See Powering Off a QFX5200.
- Remove the cables that connect the QFX5200 to all external devices.
- Remove all field-replaceable units (FRUs) from the switch.
- Have one person support the weight of the switch while another person unscrews and removes the mounting screws.
- Remove the switch from the rack or cabinet (see QFX5200 Installation Safety Guidelines) and place the switch in an antistatic bag.
- Place the switch in the shipping carton.
- Place the packing foam on top of and around the switch.
- If you are returning accessories or FRUs with the switch, pack them as instructed in Packing QFX5200 Components for Shipping.
- Replace the accessory box on top of the packing foam.
- Close the top of the cardboard shipping box and seal it with packing tape.
- Write the RMA number on the exterior of the box to ensure proper tracking.
Packing QFX5200 Components for Shipping
Do not stack switch components. Return individual components in separate boxes if they do not fit together on one level in the shipping box.
To pack and ship QFX5200 components:
Place individual FRUs in antistatic bags.
Ensure that the components are adequately protected with packing materials and packed so that the pieces are prevented from moving around inside the carton.
Close the top of the cardboard shipping box and seal it with packing tape.
Write the RMA number on the exterior of the box to ensure proper tracking.