show interfaces diagnostics optics-profile
Syntax
show interfaces diagnostics optics-profile
Description
Display diagnostic data for the supported optics (QSFP+, QSFP28, QSFP-DD). No output is displayed for unsupported optics (SFP, CFP, etc.) and for QSFP DAC (direct attach cables) modules.
Options
interface-name |
Interface name. For example:
|
Additional Information
Required Privilege Level
view
Output Fields
Table 1
lists the output fields for the show interfaces diagnostics optics-profile
command.
Field Name | Field Description |
---|---|
Optics type | Type of optics supported. Supported optics are QSFP+, QSFP28, and QSFP-DD. |
Number of lanes | Number of lanes depending on the optics connected. Number of lanes supported is 0 through 7. |
Power class | Specifies the power class. Possible values: 1 through 8. |
Power Mode | Specifies the power mode. Possible values: High or Low. |
Host Side FEC | Specifies the FEC on host side optics. Possible values: Off, On, or Unsupported. |
Media Side FEC | Specifies the FEC on media side optics. Possible values: Off, On, or Unsupported. |
Rx output manual control support | Specifies if the optics can receive output. Possible values: Yes or No. |
Tx CDR Implemented | Specifies if the transmit clock and data recovery is implemented. Possible values: Yes or No. |
Tx CDR manual control support | Specifies if the transmit clock and data recovery can be configured. Possible values: Yes or No. |
Rx CDR Implemented | Specifies if the receive clock and data recovery status is implemented. Possible values: Yes or No. |
Rx CDR manual control support | Specifies if the receive clock and data recovery can be configured. Possible values: Yes or No. |
Tx input equalization type | Specifies the Input Equalization type. Also called Continous Time Linear Equalization (CTLE). Possible values: Manual or Adaptive. |
Tx input equalization manual control | Specifies if the input equalization is manual. Possible values: Yes or No. |
Tx input equalization max value | Specifies the maximum equalization value. Possible values: 0 through 10 dB. |
Tx input equalization max settling time | Specifies the time required for the maximum equalization value. Possible values: 100 through 25500 ms. |
Rx output emphasis manual control support | Specifies if the output emphasis can be configured. Possible values: Yes or No. |
Rx output amplitude 100-400 mV no equalization | Specifies that there is no equalization for 100mV to 400mV amplitude. Possible values: Off or On. |
Rx output amplitude 300-600 mV no equalization | Specifies that there is no equalization for 300mV to 600mV amplitude. Possible values: Off or On. |
Rx output amplitude 400-800 mV no equalization | Specifies that there is no equalization for 400mV to 800mV amplitude. Possible values: Off or On. |
Rx output amplitude 600-1200 mV no equalization | Specifies that there is no equalization for 600mV to 1200mV amplitude. Possible values: Off or On. |
Tx squelch manual control support | Specifies if the transmit squelch status is configured. Possible values: Off or On. |
Rx squelch manual control support | Specifies if the receive squelch status is configured. Possible values: Off or On. |
Tx rate select version | Version of the transmit rate select option. Possible values: Version 1, Version 2, and not supported. |
Rx rate select version | Version of the receive rate select option. Possible values: Version 1, Version 2, and not supported. |
Lane | Lane number. Possible values: 0 through 7. |
Tx Laser | Specifies the status of the transmit Laser. Possible values: Off or On. |
Rx Output | Specifies if the optics can receive output. Possible values: Off or On. |
Tx CDR | Specifies if the transmit clock and data recovery status of the optics. Possible values: Off or On. |
Rx CDR | Specifies if the receive clock and data recovery status of the optics. Possible values: Off or On. |
Tx input equalization (CTLE) | Specifies if input equalization is configured. Possible values: 0 through 10 dB. |
Rx output emphasis | Specifies if the optics can receive output emphasis. Possible values : 0 through 10 dB. |
Rx output amplitude | Specifies if the optics can receive output amplitude setting. Possible values:
|
Tx squelch | Specifies the transmit squelch status of the optics. Possible values: Off or On. |
Rx squelch | Specifies the receive squelch status of the optics. Possible values: Off or On. |
Sample Output
- show interfaces diagnostics optics-profile
- show interfaces diagnostics optics-profile (for SFP, CFP, QSFP DAC)
show interfaces diagnostics optics-profile
user@host> show interfaces diagnostics optics-profile et-0/0/0
Physical interface: et-0/0/0 Optics type : QSFP28 Number of lanes : 4 Power class : class 4 (3.5 W max) Power mode : high Host side FEC : not supported Media side FEC : not supported Rx output manual control support : yes Tx CDR implemented : yes Tx CDR manual control support : yes Rx CDR implemented : yes Rx CDR manual control support : yes Tx input equalization type : manual Tx input equalization manual control support : yes Tx input equalization max value : 10 dB Tx input equalization max settling time : 100 ms Rx output emphasis manual control support : yes Rx output emphasis max value : 6 dB Rx output amplitude 100-400 mV no equalization : yes Rx output amplitude 300-600 mV no equalization : yes Rx output amplitude 400-800 mV no equalization : yes Rx output amplitude 600-1200 mV no equalization : yes Tx squelch manual control support : no Rx squelch manual control support : yes Tx rate select version : not supported Rx rate select version : not supported Lane 0 Tx laser : enabled Rx output : enabled Tx CDR : enabled Rx CDR : enabled Tx input equalization (CTLE) : 1 dB Rx output emphasis : 0 dB Rx output amplitude : 400-800 mV Tx squelch : enabled Rx squelch : enabled Lane 1 Tx laser : enabled Rx output : enabled Tx CDR : enabled Rx CDR : enabled Tx input equalization (CTLE) : 1 dB Rx output emphasis : 0 dB Rx output amplitude : 400-800 mV Tx squelch : enabled Rx squelch : enabled Lane 2 Tx laser : enabled Rx output : enabled Tx CDR : enabled Rx CDR : enabled Tx input equalization (CTLE) : 1 dB Rx output emphasis : 0 dB Rx output amplitude : 400-800 mV Tx squelch : enabled Rx squelch : enabled Lane 3 Tx laser : enabled Rx output : enabled Tx CDR : enabled Rx CDR : enabled Tx input equalization (CTLE) : 1 dB Rx output emphasis : 0 dB Rx output amplitude : 400-800 mV Tx squelch : enabled Rx squelch : enabled
show interfaces diagnostics optics-profile (for SFP, CFP, QSFP DAC)
user@host> show interfaces diagnostics optics-profile et-0/0/0
Physical interface: et-0/0/0 Optical profile diagnostics : Not supported
Release Information
Command introduced in Junos OS Evolved Release 21.1R1