mode (RFC 2544 Benchmarking Tests)

Syntax

Junos OS Hierarchy Level

Junos OS Evolved Hierarchy Level

Description

Specify the test mode for the packets that are sent during the benchmarking test.

Options

initiate-and-terminate (Most ACX routers, except for the ACX5448, ACX5048, and ACX5096) Initiate and terminate the test on the chosen service (IPv4 or Ethernet). The ACX7100, ACX7509, ACX7024, and ACX7024X devices support this mode only for an IPv4 service.
reflect

(MX routers and the ACX7100, ACX7509, ACX7024, ACX5448, ACX5048, and ACX5096 routers) Reflect the test frames on the chosen service (IPv4 or Ethernet).

Required Privilege Level

system—To view this statement in the configuration.

system-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 13.3.

Statement introduced in Junos OS Evolved Release 21.1R1 for reflect mode only.