Supported Platforms
Related Documentation
- ACX, M, MX, T Series
- Configuring E1 BERT Properties
- EX, J, M, MX, PTX, T Series
- Interface Diagnostics
Configuring T1 BERT Properties
This section discusses BERT properties for the T1 interface specifically. For general information about the Junos implementation of the BERT procedure, see Interface Diagnostics.
You can configure a T1 interface or partitioned CT1 or T1 channel to execute a bit error rate test (BERT) when the interface receives a request to run this test. You specify the duration of the test and the error rate to include in the bit stream by including the bert-period and bert-error-rate statements at the [edit interfaces interface-name t1-options] hierarchy level:
seconds is the duration of the BERT procedure. The test can last from 1 through 239 seconds; the default is 10 seconds. Standard CT1, standard T1, T1 IQ, and T1 IQE interfaces, and PICs partitioned to CT1 and T1 channels, support an extended BERT period range, up to 86,400 seconds (24 hours), and have a default BERT period value of 240 seconds.
![]() | Note: When configuring T1 and CT1 interfaces on 10-port Channelized E1/T1 IQE PICs, the bert-period statement must be included at the [edit interfaces ct1-fpc/pic/port] hierarchy level. |
![]() | Note: When configuring CT1 interfaces on the 16-port Channelized E1/T1 Circuit Emulation MIC (MIC-3D-16CHE1-T1-CE), you must include BERT configuration options at the [edit interfaces ct1-fpc/pic/port] hierarchy level. |
rate is the bit error rate. This can be an integer from 0 through 7, which corresponds to a bit error rate from 10–0 (1 error per bit) to 10–7 (1 error per 10 million bits).
algorithm is the pattern to send in the bit stream. On T1 interfaces, you can also select the pattern to send in the bit stream by including the bert-algorithm statement at the [edit interfaces interface-name interface-options] hierarchy level:
For a list of supported algorithms, enter a ? after the bert-algorithm statement; for example:
![]() | Note: The bit-error-rate statement in BERT procedure is not supported on the 16-port Channelized E1/T1 Circuit Emulation MIC (MIC-3D-16CHE1-T1-CE). |
For specific hierarchy information, see individual interface types. For information about running the BERT procedure, see the Junos OS System Basics Configuration Guide.
Related Documentation
- ACX, M, MX, T Series
- Configuring E1 BERT Properties
- EX, J, M, MX, PTX, T Series
- Interface Diagnostics
Published: 2013-01-11
Supported Platforms
Related Documentation
- ACX, M, MX, T Series
- Configuring E1 BERT Properties
- EX, J, M, MX, PTX, T Series
- Interface Diagnostics