- play_arrow Fast Track: Initial Installation
- play_arrow Site Planning, Preparation, and Specifications
- play_arrow Initial Installation and Configuration
- SRX345 Installation Overview
- Unpacking and Mounting the SRX345
- Connecting the SRX345 to Power
- Connecting the SRX345 to External Devices
- Register Products—Mandatory to Validate SLAs
- Configuring Junos OS on the SRX345
- Installing the Optional SATA Solid-State Drive in SRX340 and SRX345 Services Gateways
- play_arrow Maintaining Components
- play_arrow Troubleshooting Hardware
- play_arrow Contacting Customer Support and Returning the Chassis or Components
- play_arrow Safety and Compliance Information
- Definitions of Safety Warning Levels
- General Safety Guidelines and Warnings
- Restricted Access Warning
- Qualified Personnel Warning
- Prevention of Electrostatic Discharge Damage
- Fire Safety Requirements
- Laser and LED Safety Guidelines and Warnings
- Radiation from Open Port Apertures Warning
- Maintenance and Operational Safety Guidelines and Warnings
- Action to Take After an Electrical Accident
- General Electrical Safety Guidelines and Warnings
- AC Power Electrical Safety Guidelines
- DC Power Electrical Safety Guidelines
- SRX345 Firewall Agency Approvals
- SRX345 Firewall Acoustic Noise Compliance Statements
- SRX345 Firewall EMC Requirements
SRX345 Power System
SRX345 Firewall Power Supply
The SRX345 Firewall is available with either a single AC power supply (Junos OS Release 15.1X49-D35 and later), dual AC power supplies (Junos OS Release 15.1X49-D110 and later), or a single DC power supply (Junos OS Release 17.4R1 and later). The power supply distributes the different output voltages to the device components according to their voltage requirements. The power supply is fixed in the chassis and is not a field-replaceable unit.
To identify the SRX345 model, check the Description
field in the output of
the show chassis hardware
command.
The following are sample outputs for the different SRX345 models.
SRX345 with single AC power supply
content_copy zoom_out_mapuser@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis CZ2916AF0098 SRX345 Routing Engine REV 0x07 650-065042 CZ2916AF0098 RE-SRX345 FPC 0 FPC PIC 0 8xGE,8xGE SFP Base PIC Power Supply 0
SRX345 with single DC power supply
content_copy zoom_out_mapuser@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis DT1917AF0037 SRX345-DC Routing Engine REV 0x01 650-073731 DT1917AF0037 RE-SRX345-DC FPC 0 FPC PIC 0 8xGE,8xGE SFP Base PIC Power Supply 0
SRX345 with dual AC power supplies
content_copy zoom_out_mapuser@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis DS2617AF0021 SRX345-DUAL-AC Routing Engine REV 0x03 650-073730 DS2617AF0021 RE-SRX345-DUAL-AC FPC 0 FPC PIC 0 8xGE,8xGE SFP Base PIC Power Supply 0
If one power supply on an SRX345 (with dual AC power supplies) fails, the remaining power supply redistributes the electrical load without interruption.
See Also
SRX345 Firewall Power Specifications and Requirements
The AC power system electrical specifications for the SRX345 Firewall are listed in Table 1.
Power Requirement | Specification |
---|---|
AC input voltage | 100 to 240 VAC |
AC input line frequency | 50 to 60 Hz |
AC system current rating | 1 to 1.5 A |
Maximum AC inrush current | 7.3 A at 220 V/50 Hz (with four Mini-PIMs installed) |
The AC power cord for the services gateway is intended for use with the device only and not for any other use.
The DC power system electrical specifications for the SRX345 Firewall are listed in Table 2.
Power Requirement | Specification |
---|---|
Rated DC voltage range | –48 to –60 VDC (with -15% and +20% tolerance) |
Operating voltage range | –40.8 to –72 VDC |
DC system current rating | 6 A at –48 VDC |
DC output | 12 V@150W |
SRX345 Firewall Supported AC Power Cords
The AC power cord for the services gateway is intended for use with the services gateway only and not for any other use.
In North America, AC power cords must not exceed 4.5 m (approximately 14.75 ft) in length, to comply with National Electrical code (NEC) Section 400-8 (NFPA 75, 5-2.2) and 210-52, and Canadian Electrical Code (CEC) Section 4-010(3).
Table 3 provides power cord specifications, and Figure 1 depicts the plug on the AC power cord provided for each country or region.
Country | Electrical Specification | Plug Standards |
---|---|---|
Australia | 250 VAC, 10 A, 50 Hz | AS/NZ 3112-1993 |
China | 250 VAC, 10 A, 50 Hz | GB2099.1 1996 and GB 1002 1996 (CH1-10P) |
Europe (except Italy and United Kingdom) | 250 VAC, 10 A, 50 Hz | CEE (7) VII |
Italy | 250 VAC, 10 A, 50 Hz | CEI 23-16/VII |
Japan | 125 VAC, 12 A, 50 or 60 Hz | JIS 8303 |
North America | 125 VAC, 10 A, 60 Hz | NEMA 5-15 |
United Kingdom | 250 VAC, 10 A, 50 Hz | BS 1363A |

Power cords and cables must not block access to services gateway components or drape where people might trip on them.