- play_arrow Fast Track: Initial Installation
- play_arrow Overview
- play_arrow Site Planning, Preparation, and Specifications
- play_arrow Initial Installation and Configuration
- play_arrow Maintaining Components
- play_arrow Contacting Customer Support and Returning the Chassis or Components
- play_arrow Safety and Compliance Information
- General Safety Guidelines and Warnings
- Definitions of Safety Warning Levels
- Qualified Personnel Warning
- Warning Statement for Norway and Sweden
- Fire Safety Requirements
- Installation Instructions Warning
- Restricted Access Warning
- Ramp Warning
- Rack-Mounting and Cabinet-Mounting Warnings
- Grounded Equipment Warning
- Radiation from Open Port Apertures Warning
- Laser and LED Safety Guidelines and Warnings
- Maintenance and Operational Safety Guidelines and Warnings
- General Electrical Safety Guidelines and Warnings
- Prevention of Electrostatic Discharge Damage
- Site Electrical Wiring Guidelines
- DC Power Electrical Safety Guidelines
- DC Power Copper Conductors Warning
- DC Power Disconnection Warning
- DC Power Grounding Requirements and Warning
- DC Power Wiring Sequence Warning
- DC Power Wiring Terminations Warning
- Multiple Power Supplies Disconnection Warning
- Action to Take After an Electrical Accident
- Agency Approvals for ACX710 Routers
- Compliance Statements for Data Center
- Compliance Statements for EMC Requirements
- Compliance Statements for Environmental Requirements
Troubleshoot an ACX710 Router
Alarm Types and Severity Classes on ACX Series Routers
Before monitoring the alarms on the router, become familiar with the terms defined in Table 1.
Term | Definition |
---|---|
Alarm | Signal that alerts you to conditions that might prevent normal operation. On a router, the alarm signal is the ALM LED that is lit on the front of the chassis. |
Alarm condition | Failure event that triggers an alarm. |
Alarm severity | Seriousness of the alarm. The level of severity can be either major (steady red) or minor (steady amber). |
Chassis alarm | Predefined alarm that is triggered by a physical condition on the router, such as a power failure, excessive component temperature, or media failure. |
System alarm | Predefined alarm that is triggered by a missing rescue configuration or failure to install a license for a licensed software feature. |
Alarm Types
The router supports these alarms:
Chassis alarms indicate a failure on the router or one of its components. Chassis alarms are preset and cannot be modified.
System alarms indicate a missing rescue configuration. System alarms are preset and cannot be modified, although you can configure them to appear automatically in the J-Web interface display or CLI display.
Alarm Severity Classes
Alarms on ACX Series routers have two severity classes:
Major (steady red)—Indicates a critical situation on the router that has resulted from one of the following conditions. A major alarm condition requires immediate action.
One or more hardware components have failed.
One or more hardware components have exceeded temperature thresholds.
An alarm condition that is configured on an interface has triggered a critical warning.
Minor (steady amber)—Indicates a noncritical condition on the router that, if left unchecked, might cause an interruption in service or degradation in performance. A minor alarm condition requires monitoring or maintenance.
A missing rescue configuration generates a minor system alarm.