Table 1 summarizes the command-line interface (CLI) commands you can use to monitor the router chassis. Commands are listed in alphabetical order.

Table 1: Chassis Operational Mode Commands

Task

CLI Command

(T Series and M320 routers only) Clear or stop a text message on the craft interface.

clear chassis display message

(T Series, M120, M320, and MX Series routers only) Change Control Board (CB) status information.

request chassis cb

(PTX Series Packet Transport Routers only) Control the operation of the Centralized Clock Generator (CCG).

request chassis ccg

(M7i and M10i routers only) Control the operation of the Compact Forwarding Engine Board (CFEB).

request chassis cfeb

(TX Matrix Plus routers only) Control the operation of the Connector Interface Panel (CIP).

request chassis cip

(PTX Series Packet Transport Routers only) Control which Centralized Clock Generator (CCG) is master.

request chassis clock master switch

(M120 and MX Series routers only) Control the operation of the specified fabric plane.

request chassis fabric plane

(M120 router only) Control the operation of the specified Fowarding Engine Board (FEB).

request chassis feb

(M20, M40, M40e, M120 M160, M320, and MX Series routers: T Series routers; and PTX Series Packet Transport Swtiches only) Control the operation of the Flexible PIC Concentrator (FPC).

request chassis fpc

(M40e, M120, M160, M320, and MX Series routers, and T Series routers only) Resynchronize the Front Panel Module (FPM) craft interface status

request chassis fpm resync

(TX Matrix and TX Matrix Plus routers only) On a TX Matrix router, control the operation of the T640 router (or line-card chassis) that is connected to the TX Matrix router. On a TX Matrix Plus router, control the operation of a specified router (line-card chassis) that is connected to the TX Matrix Plus router.

request chassis lcc

(MX Series routers) Control the operation of Modular Interface Cards (MICs)

request chassis mic

(M40e and M160 routers only) Control the operation of the Miscellaneous Control Subsystem (MCS).

request chassis mcs

(MX Series routers only) Control the operation of a MIC.

request chassis mic

(M40e and M160 routers only) Control the operation of the Packet Forwarding Engine Clock Generator (PCG).

request chassis pcg

Control the operation of a PIC.

request chassis pic

(M120 routers only) Control the operation of a FEB in a redundancy group.

request chassis redundancy feb slot

For routers with multiple Routing Engines, control which Routing Engine is the master.

request chassis routing-engine master

(T Series routers only) Control the operation of the specified SONET Clock Generator (SCG).

request chassis scg

(M40e and M160 routers only) Control which Switching and Forwarding Module (SFM) is master.

request chassis sfm master switch

(M40e and M160 routers only) Control the operation of the specified SFM.

request chassis sfm

(M320 routers and T Series routers only) Control the operation of the specified Switch Interface Board (SIB).

request chassis sib

(TX Matrix Plus routers only) Control the receiving link of the specified Switch Interface Board (SIB) of the SFC.

request chassis sib f13 train-link-receive slot

(TX Matrix Plus routers only) Control the transmission link of the specified Switch Interface Board (SIB) of the SFC.

request chassis sib f13 train-link-transmit slot

(T1600 routers (LCCs) and TX Matrix Plus routing platform only) Control the receiving link of the specified Switch Interface Board (SIB) of the LCC.

request chassis sib train-link-receive slot

(T1600 routers (LCCs) and TX Matrix Plus routing platform only) Control the transmission link of the specified Switch Interface Board (SIB) of the LCC.

request chassis sib train-link-transmit slot

(T Series routers only) Restart the specified Switch Processor Mezzanine Board (SPMB) on the CB.

request chassis spmb restart

On MX80, MX240, MX480, and MX960 routers and PTX Series Packet Transport Routers, you can change the chassis synchronization source used for synchronized Ethernet (Sync-E) configuration. This feature is not supported on MX80T routers.

request chassis synchronization mode

(M320 routers and PTX Series Packet Transport Routers only) Change the external clock source used for chassis synchronization.

request chassis synchronization switch

Send a message to the router's craft interface.

set chassis display message

Display chassis alarm status.

show chassis alarms

(M7i and M10i routers only) Change and display CFEB status information.

show chassis cfeb

(TX Matrix Plus routers only) Display environmental information about the CIP.

show chassis cip

View information that is currently displayed on the craft interface.

show chassis craft-interface

Display environmental information about the router chassis, including the temperature and information about the fans, power supplies, and Routing Engine.

show chassis environment

(T Series, M120, M320, and MX Series routers; and PTX Series Packet Transport Routersonly) Display CB environmental information.

show chassis environment cb

(PTX Series Packet Transport Routers) Display environmental information about the Centralized Clock Generator.

show chassis environment ccg

(TX Matrix Plus router only) Display environmental information about the Connector Interface Panel (CIP).

show chassis environment cip

(M20, M40, M40e, M120, M160, M320, and MX Series routers: T Series routers; and PTX Series Packet Transport Routers only) Display FPC environmental status information.

show chassis environment fpc

(M20, M40, M40e, M120, M160, M320, and MX Series routers; T Series routers; and PTX Series Packet Transport Swtiches only) Change and display FPM status information.

show chassis environment fpm

(M40e and M160 routers only) Display MCS environmental status information.

show chassis environment mcs

(PTX Series Packet Transport Routers) Display status information for monitored temperatures.

show chassis environment monitored

Display generic environmental information.

show chassis environment

(M40e and M160 routers only) Display PCG environmental status information.

show chassis environment pcg

(PTX Series Packet Transport Routers) Display environmental information about Power Distribution Units (PDUs).

show chassis environment pdu

(M40e, M120, M160, M320, and MX Series routers, and T Series routers only) Display Power Entry Module (PEM) environmental status information.

show chassis environment pem

Display Routing Engine environmental status information.

show chassis environment routing-engine

(T Series routers only) Display SCG environmental information.

show chassis environment scg

(M40e and M160 routers only) Display SFM environmental information.

show chassis environment sfm

(M320 routers, T Series routers, and PTX Series Packet Transport Routers only) Display SIB environmental information.

show chassis environment sib

(M10i, M40e, M120, M160, M320, and MX Series routers;T Series routers: and PTX Series Packet Transport Routers only) Display information about the ports on the CB Ethernet switch.

show chassis ethernet-switch

(MX Series routers only) Display information about the fan and fan trays.

show chassis fan

(MX Series routers only) Display the state of fabric destinations for all FPCs.

show chassis fabric destinations

(M120 router only) Display the state of the electrical and optical switching fabric link between the FEBs and the fabric planes, as interpreted by the FEB.

show chassis fabric feb

(TX Matrix Plus routers only) Display chassis fabric errors for FPCs and SIBs.

show chassis fabric errors

(M320 and MX Series routers and T Series router only) Display the state of the electrical and optical switch fabric links between the FPCs and the SIBs.

show chassis fabric fpcs

(T640 and T1600 routers only) Display the state of fabric destination reachability , based on periodic reachability checks.

show chassis fabric reachability

(MX240, MX480, and MX960 routers only) Display whether redundancy mode is configured for active control boards to enable increased fabric bandwidth usage.

show chassis fabric redundancy-mode

(T640 and T1600 routers only) Display the list of destinations that have transitioned from a reachable state to an unreachable state.

show chassis fabric unreachable-destinations

(M120 and MX Series routers only) Display the state of the switching fabric map for connections from the FEBs to the ports on the fabric planes, as interpreted by the fabric plane.

show chassis fabric map

(TX Matrix Plus routers with 3D SIBs only) Display information about the optical ports on the TX Matrix Plus router (or the switch-fabric chassis (SFC)) and on the T1600 or T4000 line-card chassis (LCCs) connected to it in a routing matrix.

show chassis fabric optics

(TX Matrix Plus routers with 3D SIBs only) Display optical link connectivity and its current status. This command shows status of all the optical links on online SIBs at one place along with the state of optical-link, high speed link status and mapped FPCs.

show chassis fabric optical-links

(M120, MX Series, T1600, and TX Matrix Plus routers only) Display the state of all fabric plane connections to the FEBs. On a TX Matrix Plus router, display the state of the fabric management plane and the logical planes on the SFC and line-card chassis (LCC)

show chassis fabric plane

(M120, MX Series, T1600, and TX Matrix Plus router only) Display the CB location of each plane.

show chassis fabric plane-location

(T Series routers only) Display the state of the electrical and optical switch fabric links:

  • Between the SIBs in the TX Matrix router and the SIBs in the T640 routers.
  • Between the T640 SIBs and the FPCs in a T640 router.

show chassis fabric sibs

(T Series routers only) Display the state of the switching fabric topology for the SIB connection between the TX Matrix router and the T640 routers.

show chassis fabric topology

(M5, M10, and M120 routers only). Display FEB status information.

show chassis feb

Display the version levels of the firmware running on the SCB, SFM, SSB, FEB, and FPCs.

show chassis firmware

(J Series Services Routers only) Display status of the forwarding process (fwdd).

show chassis forwarding

(M20, M40, M40e, M160, and M320 routers: MX Series routers: T Series routers; and PTX Series Packet Transport Swtiches only) Display FPC status information.

show chassis fpc

(M120 router only) Display the FPC and FEB mapping and their respective states.

show chassis fpc-feb-connectivity

Display hardware inventory.

show chassis hardware

Display the status of the most recent unified in-service software upgrade (ISSU).

show chassis in-service-upgrade

(TX Matrix and TX Matrix Plus router only) On a TX Matrix router, display the status of all T640 routers (or line-card chassis) connected to the TX Matrix router. On a TX Matrix Plus router, display the status of all routers (or line-card chassis) connected to the TX Matrix Plus router.

show chassis lccs

(TX Matrix Plus router only) Display the mode in which the LCCs are connected to the TX Matrix Plus router.

show chassis lcc-mode

Display chassis location information.

show chassis location

Display MAC address information.

show chassis mac-addresses

Display the network services mode.

show chassis network services

Display the operations support systems (OSS) mapping details.

show chassis oss-map

Display PIC status information.

show chassis pic

(J Series routers only) Display PIM power ratings.

show chassis power-ratings

(MX Series 3D Universal Edgerouters and PTX Series Packet Transport Swtiches only) Display power limits and usage.

show chassis power

(MX Series 3D Universal Edgerouters and PTX Series Packet Transport Routers only) Show power-on sequence for the chassis DPCs.

show chassis power sequence

(Root System Domain [RSD] only) Display information about Protected System Domains (PSDs).

show chassis psd

(M120 routers only) Display status information about configured FEB redundancy groups.

show chassis redundancy feb

Display the information about one or more Routing Engines.

show chassis routing-engine

(M40 router only) Display System Control Board (SCB) status information.

show chassis scb

(M40e and M160 routers only) Change and display SFM status information.

show chassis sfm

(M320 routers and T Series routers only) Display SIB status information.

show chassis sibs

(T Series routers only) Display SPMB status information.

show chassis spmb

(T Series routers only) Display SPMB Switch Interface Board (SIB) status information.

show chassis spmb sibs

(M320 routers and PTX Series Packet Transport Swtiches only) Display information about the external clock source currently used for chassis synchronization.

show chassis synchronization

Display chassis temperature threshold settings, in degrees Celsius.

show chassis temperature-thresholds

Display status of the cooling system zones.

show chassis zones

show chassis zones (PTX Series Packet Transport Routers)

Note: For information about how to configure chassis parameters, such as conditions that activate the alarm LEDs on the router's craft interface, properties for specific PICs, and redundancy, see the.Junos OS Administration Library for Routing Devices.

For information about related tasks performed by network operations center (NOC) personnel, see the Junos Hardware Network Operations Guide.

Published: 2013-07-24