Limiting the Number of Concurrent RPM Probes on M, MX, T and PTX Routers and EX Series Switches
To configure the maximum number of concurrent probes allowed,
include the probe-limit
statement at the [edit services
rpm]
hierarchy level:
probe-limit limit;
Specify a limit from 1
through 500
. The
default maximum number is 100.
Starting in Junos OS Release 17.2R2 and 17.3R1 for MX Series routers only, the probe-limit is 1 through 2000.
Change History Table
Feature support is determined by the platform and release you are using. Use Feature Explorer to determine if a feature is supported on your platform.
Release
Description
17.2R2
Starting in Junos OS
Release 17.2R2 and 17.3R1 for MX Series routers only, the probe-limit
is 1 through 2000.