Limiting the Number of Concurrent RPM Probes on M, MX, T and PTX Routers and EX Series Switches

To configure the maximum number of concurrent probes allowed, include the probe-limit statement at the [edit services rpm] hierarchy level:

Specify a limit from 1 through 500. The default maximum number is 100.

Starting in Junos OS Release 17.2R2 and 17.3R1 for MX Series routers only, the probe-limit is 1 through 2000.

Change History Table

Feature support is determined by the platform and release you are using. Use Feature Explorer to determine if a feature is supported on your platform.

Release
Description
17.2R2
Starting in Junos OS Release 17.2R2 and 17.3R1 for MX Series routers only, the probe-limit is 1 through 2000.