Associating Sampling Instances for Active Flow Monitoring with a Specific FPC, MPC, or DPC

date_range 01-Dec-23

The Junos OS enables you to configure sampling instances for active flow monitoring, by specifying a name for the sampling parameters and associating the instance name with a specific FPC, MPC, or DPC.

To configure active sampling instances, include the instance statement at the [edit forwarding-options sampling] hierarchy level. For more information about configuring sampling instances, see the Junos OS Services Interfaces Library for Routing Devices.

To associate a configured active sampling instance with a specific FPC, MPC, or DPC, include the sampling instance name at the [edit chassis fpc slot-number] hierarchy level:

content_copy zoom_out_map
[edit chassis fpc slot-number]
sampling-instance instance-name;

On a TX Matrix, TX Matrix Plus router, include the sampling-instance statement at the [edit chassis lcc number fpc slot-number] hierarchy level:

content_copy zoom_out_map
[edit chassis lcc number fpc slot-number]
sampling-instance instance-name;