- play_arrow Fast Track: Initial Installation
- play_arrow Overview
- play_arrow System Overview
- play_arrow Chassis Components and Descriptions
- MX960 Chassis Description
- MX960 Component Redundancy
- MX960 Router Hardware and CLI Terminology Mapping
- MX960 Midplane Description
- MX960 Rack-Mounting Hardware
- MX960 Craft Interface Overview
- MX960 Alarm Relay Contacts on the Craft Interface
- MX960 Alarm LEDs and Alarm Cutoff/Lamp Test Button
- MX960 Component LEDs on the Craft Interface
- MX960 Cable Manager Description
- play_arrow Cooling System Components and Descriptions
- play_arrow Host Subsystem Components and Descriptions
- play_arrow Interface Modules—DPCs
- play_arrow Interface Modules—FPCs and PICs
- play_arrow Interface Modules—MPCs and MICs
- MX960 Application Services Modular Line Card Description
- MX960 Application Services Modular Storage Card Description
- MX960 Application Services Modular Processing Card Description
- MX960 AS MSC LEDs
- MX960 AS MXC LEDs
- MIC/MPC Compatibility
- MX960 Modular Interface Card Description
- MX960 Modular Interface Card (MIC) LEDs
- MICs Supported by MX Series Routers
- MX960 MIC Port and Interface Numbering
- MX960 Modular Port Concentrator Description
- MX960 Modular Port Concentrator LEDs
- MPCs Supported by MX Series Routers
- play_arrow Services Processing Card—MX-SPC3
- play_arrow Power System Components and Descriptions
- play_arrow Switch Control Board Components and Descriptions
-
- play_arrow Initial Installation and Configuration
- play_arrow Unpacking the MX960 Router
- play_arrow Installing the Mounting Hardware
- play_arrow Installing the MX960 Router
- Installing an MX960 Router Overview
- Removing Components from the MX960 Router Chassis Before Installing It with a Lift
- Tools Required to Install the MX960 Router with a Mechanical Lift
- Installing the MX960 Router Using a Mechanical Lift
- MX960 Acoustic Cover Installation Instructions
- MX960 Extended Cable Manager Installation Instructions
- Reinstalling Components in the MX960 Chassis After Installing It with a Lift
- play_arrow Connecting the MX960 Router to Power
- Tools and Parts Required for MX960 Router Grounding and Power Connections
- Grounding the MX960 Router
- Connecting Power to an AC-Powered MX960 Router with Normal-Capacity Power Supplies
- Connecting Power to an AC-Powered MX960 Router with High-Capacity Power Supplies
- Connecting Power to an AC-Powered MX960 Router with High-Capacity Second-Generation Power Supplies
- Powering On an AC-Powered MX960 Router with Normal Capacity Power Supplies
- Connecting Power to a DC-Powered MX960 Router with Normal-Capacity Power Supplies
- Connecting Power to a DC-Powered MX960 Router with High-Capacity Power Supplies
- Powering On a DC-Powered MX960 Router with Normal Capacity Power Supplies
- Connecting Power to an MX960 Router with High-Voltage Second-Generation Universal (HVAC or HVDC) Power Supplies
- Powering Off the MX960 Router
- Connecting an MX960 AC Power Supply Cord
- Connecting an MX960 DC Power Supply Cable
- play_arrow Connecting the MX960 Router to the Network
- Tools and Parts Required for MX960 Router Connections
- Connecting the MX960 Router to Management and Alarm Devices
- Connecting the MX960 Router to a Network for Out-of-Band Management
- Connecting the MX960 Router to a Management Console or Auxiliary Device
- Connecting an MX960 Router to an External Alarm-Reporting Device
- Connecting DPC, MPC, MIC, or PIC Cables to the MX960 Router
- Connecting the Alarm Relay Wires to the MX960 Craft Interface
- Register Products—Mandatory to Validate SLAs
- play_arrow Initially Configuring the MX960 Router
-
- play_arrow Installing and Replacing Components
- play_arrow Overview of Installing and Replacing Components
- play_arrow Installing Components
- Installing the MX960 Craft Interface
- Installing the MX960 Air Filter
- Installing an MX960 Fan Tray
- Installing an MX960 Routing Engine
- Installing an MX960 Switch Control Board
- Installing an MX960 DPC
- Installing an MX960 FPC
- Installing an MX960 MIC
- Installing an MX960 Dual-Wide MIC
- Installing an MX960 MPC
- Installing an MX960 PIC
- Installing a Cable on an MX960 DPC, MPC, MIC, or PIC
- Installing a MX960 AC Power Supply or High-Voltage Second-Generation Universal (HVAC or HVDC)
- Installing an MX960 DC Power Supply
- Installing an MX960 AS MLC
- Installing an MX960 AS MSC
- Installing an MX960 AS MXC
- Installing an SFP or XFP Transceiver into an MX960 DPC, MPC, MIC, or PIC
- Replacing a CFP2 Transceiver
- Replacing a CFP Transceiver
- play_arrow Replacing Chassis Components
- play_arrow Replacing Cooling System Component
- play_arrow Replacing Host Subsystem Components
- Replacing an MX960 Routing Engine
- Replacing an SSD Drive on an RE-S-1800
- Replacing an SSD Drive on an RE-S-X6-64G
- Replacing Connections to MX960 Routing Engine Interface Ports
- Upgrading to the RE-S-X6-64G Routing Engine in a Redundant Host Subsystem
- Upgrading to the RE-S-X6-64G Routing Engine in a Nonredundant Host Subsystem
- play_arrow Replacing Line Card Components
- play_arrow Replacing Power System Components
- play_arrow Replacing and Upgrading Switch Control Boards
-
- play_arrow Maintaining the Chassis and Components
- play_arrow Routine Maintenance Procedures
- play_arrow Maintaining Components
- Tools and Parts Required to Maintain the MX960 Router
- Maintaining the MX960 Air Filter
- Maintaining the MX960 Fan Trays
- Maintaining the MX960 Host Subsystem
- Maintaining MX960 DPCs
- Holding an MX960 DPC
- Storing an MX960 DPC
- Maintaining MX960 FPCs
- Holding an MX960 FPC
- Storing an MX960 FPC
- Maintaining MX960 MICs
- Maintaining MX960 MPCs
- Maintaining MX960 PICs
- Maintaining Cables That Connect to MX960 DPCs, MPCs, MICs, or PICs
- Maintaining MX-SPC3 Services Card
- Maintaining the MX960 Power Supplies
- Verifying the Version of the MX960 Cable Manager
- play_arrow Converting to a Different Type of Power Supply
-
- play_arrow Troubleshooting Hardware
- play_arrow Knowledge Base
- play_arrow Troubleshooting Components
-
- play_arrow Contacting Customer Support and Returning the Chassis or Components
- play_arrow Contacting Customer Support
- play_arrow Locating Component Serial Numbers
- Displaying MX960 Router Components and Serial Numbers
- MX960 Routing Engine Serial Number Label
- MX960 Chassis Serial Number and Agency Label
- MX960 Craft Interface Serial Number Label
- MX960 Fan Tray Serial Number Label
- MX960 Power Supply Serial Number Labels
- MX960 MIC Serial Number Label
- MX960 MPC Serial Number Label
- MX960 PIC Serial Number Label
- MX960 FPC Serial Number Label
- MX960 DPC Serial Number Label
- MX960 SCB Serial Number Label
- MX960 Midplane Serial Number Label
- Contact Customer Support
- play_arrow Packing and Returning Components
-
- play_arrow Safety and Compliance Information
- play_arrow General Safety Guidelines and Warnings
- play_arrow Installation and Maintenance Safety Guidelines and Warnings
- play_arrow Radiation and Laser Warnings
- play_arrow Maintenance and Operational Safety Guidelines and Warnings
- play_arrow Electrical Safety Guidelines and Warnings
- General Electrical Safety Guidelines and Warnings
- Prevention of Electrostatic Discharge Damage
- AC Power Electrical Safety Guidelines
- AC Power Disconnection Warning
- DC Power Copper Conductors Warning
- DC Power Disconnection Warning
- DC Power Grounding Requirements and Warning
- DC Power Wiring Sequence Warning
- DC Power Wiring Terminations Warning
- Midplane Energy Hazard Warning
- Multiple Power Supplies Disconnection Warning
- Action to Take After an Electrical Accident
- play_arrow Agency Approvals and Compliance Statements
- Agency Approvals for MX960 Routers
- Compliance Statements for NEBS for the MX960 Router
- Compliance Statements for EMC Requirements for the MX960 Router
- Compliance Statements for Environmental Requirements
- Compliance Statements for Acoustic Noise for the MX960 Router
- Statements of Volatility for Juniper Network Devices
-
MX960 Router Physical Specifications
Table 1 summarizes the physical specifications for the router chassis.
Description | Weight | Width | Depth | Height |
---|---|---|---|---|
Standard chassis dimensions | Standard chassis with midplane, two fan trays, air filter, and standard cable manager: 150 lb (68.04 kg) Standard chassis with maximum configuration: 350 lb (158.76 kg) Standard chassis with components removed: 150 lb (68.04 kg) | 17.37 in. (44.11 cm) (excluding the mounting flanges or brackets) | 23.0 in. (58.42 cm) (from front-mounting flange to chassis rear) Total depth (including standard cable manager) 27.75 in. (70.49 cm) | 27.75 in. (70.49 cm) |
Router with extended cable manager installed | Chassis with midplane, two fan trays, air filter, and extended cable manager: 174 lb (78.93 kg) Chassis with extended cable manager and maximum configuration: 374 lb (169.64 kg) Chassis with components removed: 174 lb (78.93 kg) | 17.37 in. (44.11 cm) (excluding the mounting flanges or brackets) | 23.0 in. (58.42 cm) (from front-mounting flange to chassis rear) Total depth (including extended cable manager) approximately 29.00 in. (73.7 cm) | 36.5 in. (92.7 cm) high |
Router with high-capacity power supplies installed | Standard chassis with midplane, two fan trays, air filter, and standard cable manager: 195 lb (88.45 kg) Standard chassis with maximum configuration: 395 lb (179.17 kg) Standard chassis with components removed: 195 lb (88.45 kg) | 17.37 in. (44.11 cm) (excluding the mounting flanges or brackets) | Router with high-capacity power supplies installed. Depth with high-capacity AC power supply is 30.65" (77.9 cm); depth with high-capacity DC power supply is 32.85" (83.4 cm). | 27.75 in. (70.49 cm) |
Craft interface | 1.5 lb (0.68 kg) | 17 in (43.2 cm) | 8.5 in (21.6 cm) | 6.25 in (15.9 cm) |
DPC | Maximum up to 14.5 lb (6.6 kg) Blank panel in DPC slot: 9 lb | 17 in (43.2 cm) | 22 in (55.9 cm) | 1.25 in (3.2 cm) |
FPC | FPC2: 15 lb (6.8 kg) FPC3: 14 lb (6.5 kg) | 17 in (43.2 cm) | 22 in (55.9 cm) | 2.5 in (6.4 cm) |
PIC | 2 lb (0.9 kg) | 7.75 in (28.3 cm) | 11.125 in (19.7 cm) | 4.125 in (10.5 cm) |
MPC weight (fixed configuration) | 18.35 lb (8.3 kg) | 17 in (43.2 cm) | 22 in (55.9 cm) | 1.25 in (3.2 cm) |
MPC (without MICs) | 14 lb (6.4 kg) | 17 in (43.2 cm) | 22 in (55.9 cm) | 1.25 in (3.2 cm) |
MIC | Maximum up to 1.2 lb (0.54 kg) | 6.25 in (15.9 cm) | 6.8 in (17.3 cm) | 1.25 in (3.2 cm) |
AC power supply | 5 lb (2.3 kg) each | 14.5 in (36.8 cm) | 4 in (10.2 cm) | 1.75 in (4.4 cm) |
High-capacity AC power supply | 11.9 lb (5.4 kg) each | 14.5 in (36.8 cm) | 6.85 in (12.92 cm) | 1.75 in (4.4 cm) |
DC power supply | 3.8 lb (1.7 kg) | 14.5 in (36.8 cm) | 4 in (10.2 cm) | 1.75 in (4.4 cm) |
High-capacity DC power supply | 15.8 lb (7.2 kg) | 14.5 in (36.8 cm) | 9.05 in (22.99 cm) | 1.75 in (4.4 cm) |
High-capacity second-generation AC power supply | 10.4 lb (4.72 kg) each | 14.5 in (36.8 cm) | 5.25 in (13.334 cm) | 1.75 in (4.4 cm) |
High-voltage second-generation universal (HVAC or HVDC) power supply | 11.9 lb (5.4 kg) each | 14.5 in (36.8 cm) | 5.20 in (13.21 cm) | 1.75 in (4.4 cm) |
Air filter | 1 lb (0.5 kg) | 16.7 in (42.4 cm) | 19.7 in (50 cm) | 0.43 in (1.1 cm) |
SCB | 9.6 lb (4.4 kg) (with Routing Engine installed) | 17 in (43.2 cm) | 22 in (55.9 cm) | 1.25 in (3.2 cm) |
SCBE | 9.6 lb (4.4 kg) (with Routing Engine installed) | 17 in (43.2 cm) | 22 in (55.9 cm) | 1.25 in (3.2 cm) |
SCBE2 | 9.6 lb (4.4 kg) (with Routing Engine installed) | 17 in (43.2 cm) | 22 in (55.9 cm) | 1.25 in (3.2 cm) |
Routing Engine | 2.4 lb (1.1 kg) | 11 in (27.9 cm) | 7.75 in (19.7 cm) | 1.25 in (3.2 cm) |
Routing Engine (RE-S-1800) | 2.4 lb (1.1 kg) | 11 in (27.9 cm) | 7.75 in (19.7 cm) | 1.25 in (3.2 cm) |
Routing Engine (RE-S-X6-64G) | 2.69 lb (1.18 kg) | 10.7 in (27.18 cm) | 7.47 in (18.97 cm) | 1.19 in (3.02 cm) |
Upper fan tray | 13 lb (5.9 kg) | 16.9 in (43 cm) | 20.6 in (52.3 cm) | 1.4 in (3.6 cm) |
Lower fan tray | 13 lb (5.9 kg) | 16.9 in (43 cm) | 20.6 in (52.3 cm) | 1.4 in (3.6 cm) |
High-capacity fan tray | 13 lb (5.9 kg) | 16.9 in (43 cm) | 20.6 in (52.3 cm) | 1.4 in (3.6 cm) |
Standard cable manager | 4.1 lb (1.9 kg | 18.9 in (43 cm) | 5.5 in (14 cm) | 6.7 in (17 cm) |
Extended cable manager | 39 lb (2.3 kg) | 24.5 in (62.2 cm) | 30 in (78 cm) | 24.25 in (61.6 cm) |