Connecting the Alarm Relay Wires to the MX960 Craft Interface

date_range 06-May-21

To connect the alarm relay wires between a router and an alarm-reporting device (see Figure 1):

  1. Prepare the required length of replacement wire with gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm2).
  2. Insert the replacement wires into the slots in the front of the block. Use a 2.5-mm flat-blade screwdriver to tighten the screws and secure the wire.
  3. Attach an ESD grounding strap to your bare wrist, and connect the other end of the strap to an ESD grounding point.
  4. Plug the terminal block into the relay contact, and use a 2.5-mm flat-blade screwdriver to tighten the screws on the face of the block.
  5. Attach the other end of the wires to the external device.
Figure 1: Alarm Relay ContactsAlarm Relay Contacts