- play_arrow Fast Track: Initial Installation
- play_arrow Overview
- play_arrow System Overview
- play_arrow Chassis Components and Descriptions
- MX960 Chassis Description
- MX960 Component Redundancy
- MX960 Router Hardware and CLI Terminology Mapping
- MX960 Midplane Description
- MX960 Rack-Mounting Hardware
- MX960 Craft Interface Overview
- MX960 Alarm Relay Contacts on the Craft Interface
- MX960 Alarm LEDs and Alarm Cutoff/Lamp Test Button
- MX960 Component LEDs on the Craft Interface
- MX960 Cable Manager Description
- play_arrow Cooling System Components and Descriptions
- play_arrow Host Subsystem Components and Descriptions
- play_arrow Interface Modules—DPCs
- play_arrow Interface Modules—FPCs and PICs
- play_arrow Interface Modules—MPCs and MICs
- MX960 Application Services Modular Line Card Description
- MX960 Application Services Modular Storage Card Description
- MX960 Application Services Modular Processing Card Description
- MX960 AS MSC LEDs
- MX960 AS MXC LEDs
- MIC/MPC Compatibility
- MX960 Modular Interface Card Description
- MX960 Modular Interface Card (MIC) LEDs
- MICs Supported by MX Series Routers
- MX960 MIC Port and Interface Numbering
- MX960 Modular Port Concentrator Description
- MX960 Modular Port Concentrator LEDs
- MPCs Supported by MX Series Routers
- play_arrow Services Processing Card—MX-SPC3
- play_arrow Power System Components and Descriptions
- play_arrow Switch Control Board Components and Descriptions
-
- play_arrow Site Planning, Preparation, and Specifications
- play_arrow Preparation Overview
- play_arrow Transceiver and Cable Specifications
- play_arrow Pinout Specifications
- play_arrow AC Power Requirements, Specifications, and Guidelines
- play_arrow DC Power Requirements, Specifications, and Guidelines
- play_arrow High-Voltage Second-Generation Universal (HVAC or HVDC) Power Requirements, Specifications, and Guidelines
- Electrical Specifications for the MX960 High-Voltage Second-Generation Universal (HVAC/HVDC) Power Supply
- Power Requirements for an MX960 Router
- Calculating Power Requirements for MX960 Routers
- High-Voltage Second-Generation Universal (HVAC or HVDC) Power Circuit Breaker Requirements for the MX960 Router
- High-Voltage Second-Generation Universal (MX960-PSM-HV) Power Cord Specifications for the MX960 Router
-
- play_arrow Initial Installation and Configuration
- play_arrow Unpacking the MX960 Router
- play_arrow Installing the Mounting Hardware
- play_arrow Installing the MX960 Router
- Installing an MX960 Router Overview
- Removing Components from the MX960 Router Chassis Before Installing It with a Lift
- Tools Required to Install the MX960 Router with a Mechanical Lift
- Installing the MX960 Router Using a Mechanical Lift
- MX960 Acoustic Cover Installation Instructions
- MX960 Extended Cable Manager Installation Instructions
- Reinstalling Components in the MX960 Chassis After Installing It with a Lift
- play_arrow Connecting the MX960 Router to Power
- Tools and Parts Required for MX960 Router Grounding and Power Connections
- Grounding the MX960 Router
- Connecting Power to an AC-Powered MX960 Router with Normal-Capacity Power Supplies
- Connecting Power to an AC-Powered MX960 Router with High-Capacity Power Supplies
- Connecting Power to an AC-Powered MX960 Router with High-Capacity Second-Generation Power Supplies
- Powering On an AC-Powered MX960 Router with Normal Capacity Power Supplies
- Connecting Power to a DC-Powered MX960 Router with Normal-Capacity Power Supplies
- Connecting Power to a DC-Powered MX960 Router with High-Capacity Power Supplies
- Powering On a DC-Powered MX960 Router with Normal Capacity Power Supplies
- Connecting Power to an MX960 Router with High-Voltage Second-Generation Universal (HVAC or HVDC) Power Supplies
- Powering Off the MX960 Router
- Connecting an MX960 AC Power Supply Cord
- Connecting an MX960 DC Power Supply Cable
- play_arrow Connecting the MX960 Router to the Network
- Tools and Parts Required for MX960 Router Connections
- Connecting the MX960 Router to Management and Alarm Devices
- Connecting the MX960 Router to a Network for Out-of-Band Management
- Connecting the MX960 Router to a Management Console or Auxiliary Device
- Connecting an MX960 Router to an External Alarm-Reporting Device
- Connecting DPC, MPC, MIC, or PIC Cables to the MX960 Router
- Connecting the Alarm Relay Wires to the MX960 Craft Interface
- Register Products—Mandatory to Validate SLAs
- play_arrow Initially Configuring the MX960 Router
-
- play_arrow Installing and Replacing Components
- play_arrow Overview of Installing and Replacing Components
- play_arrow Installing Components
- Installing the MX960 Craft Interface
- Installing the MX960 Air Filter
- Installing an MX960 Fan Tray
- Installing an MX960 Routing Engine
- Installing an MX960 Switch Control Board
- Installing an MX960 DPC
- Installing an MX960 FPC
- Installing an MX960 MIC
- Installing an MX960 Dual-Wide MIC
- Installing an MX960 MPC
- Installing an MX960 PIC
- Installing a Cable on an MX960 DPC, MPC, MIC, or PIC
- Installing a MX960 AC Power Supply or High-Voltage Second-Generation Universal (HVAC or HVDC)
- Installing an MX960 DC Power Supply
- Installing an MX960 AS MLC
- Installing an MX960 AS MSC
- Installing an MX960 AS MXC
- Installing an SFP or XFP Transceiver into an MX960 DPC, MPC, MIC, or PIC
- Replacing a CFP2 Transceiver
- Replacing a CFP Transceiver
- play_arrow Replacing Chassis Components
- play_arrow Replacing Cooling System Component
- play_arrow Replacing Host Subsystem Components
- Replacing an MX960 Routing Engine
- Replacing an SSD Drive on an RE-S-1800
- Replacing an SSD Drive on an RE-S-X6-64G
- Replacing Connections to MX960 Routing Engine Interface Ports
- Upgrading to the RE-S-X6-64G Routing Engine in a Redundant Host Subsystem
- Upgrading to the RE-S-X6-64G Routing Engine in a Nonredundant Host Subsystem
- play_arrow Replacing Line Card Components
- play_arrow Replacing Power System Components
- play_arrow Replacing and Upgrading Switch Control Boards
-
- play_arrow Maintaining the Chassis and Components
- play_arrow Routine Maintenance Procedures
- play_arrow Maintaining Components
- Tools and Parts Required to Maintain the MX960 Router
- Maintaining the MX960 Air Filter
- Maintaining the MX960 Fan Trays
- Maintaining the MX960 Host Subsystem
- Maintaining MX960 DPCs
- Holding an MX960 DPC
- Storing an MX960 DPC
- Maintaining MX960 FPCs
- Holding an MX960 FPC
- Storing an MX960 FPC
- Maintaining MX960 MICs
- Maintaining MX960 MPCs
- Maintaining MX960 PICs
- Maintaining Cables That Connect to MX960 DPCs, MPCs, MICs, or PICs
- Maintaining MX-SPC3 Services Card
- Maintaining the MX960 Power Supplies
- Verifying the Version of the MX960 Cable Manager
- play_arrow Converting to a Different Type of Power Supply
-
- play_arrow Troubleshooting Hardware
- play_arrow Knowledge Base
- play_arrow Troubleshooting Components
-
- play_arrow Safety and Compliance Information
- play_arrow General Safety Guidelines and Warnings
- play_arrow Installation and Maintenance Safety Guidelines and Warnings
- play_arrow Radiation and Laser Warnings
- play_arrow Maintenance and Operational Safety Guidelines and Warnings
- play_arrow Electrical Safety Guidelines and Warnings
- General Electrical Safety Guidelines and Warnings
- Prevention of Electrostatic Discharge Damage
- AC Power Electrical Safety Guidelines
- AC Power Disconnection Warning
- DC Power Copper Conductors Warning
- DC Power Disconnection Warning
- DC Power Grounding Requirements and Warning
- DC Power Wiring Sequence Warning
- DC Power Wiring Terminations Warning
- Midplane Energy Hazard Warning
- Multiple Power Supplies Disconnection Warning
- Action to Take After an Electrical Accident
- play_arrow Agency Approvals and Compliance Statements
- Agency Approvals for MX960 Routers
- Compliance Statements for NEBS for the MX960 Router
- Compliance Statements for EMC Requirements for the MX960 Router
- Compliance Statements for Environmental Requirements
- Compliance Statements for Acoustic Noise for the MX960 Router
- Statements of Volatility for Juniper Network Devices
-
Displaying MX960 Router Components and Serial Numbers
Before contacting Juniper Networks, Inc. to request a Return Materials Authorization (RMA), you must find the serial number on the router or component. To display all of the router components and their serial numbers, enter the following command-line interface (CLI) command:
user@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis JN107FC5DAFA MX960 Midplane REV 02 710-013698 CC6220 MX960 Midplane FPM Board REV 01 710-014974 JS4208 MX960 Front Panel Displ ay PIM Rev 02 740-013110 QCS10375009 Power Inlet Module PEM 0 Rev 01 740-013682 QCS10374009 PS 1.7kW; 200-240VAC in PEM 1 Rev 01 740-013682 QCS10374029 PS 1.7kW; 200-240VAC in Routing Engine 0 REV 02 740-013063 1000639065 RE-S-2000 Routing Engine 1 REV 04 740-013063 1000664335 RE-S-2000 CB 0 REV 02.6 710-013385 JM7908 MX960 SCB CB 1 REV 03 710-013385 JS9412 MX960 SCB FPC 2 REV 03 710-013699 JS4284 MX960 40GE DPC CPU REV 04 710-013713 JS9401 MX960 DPC PMB PIC 0 BUILTIN BUILTIN 10x 1GE Xcvr 0 REV 01 740-011613 P9F1ANQ SFP-SX Xcvr 1 REV 01 740-011613 P9F1ANB SFP-SX Xcvr 2 REV 01 740-011613 P9F18GT SFP-SX Xcvr 3 REV 01 740-011613 P9F1AP1 SFP-SX Xcvr 4 REV 01 740-011613 P9F1ANF SFP-SX Xcvr 5 REV 01 740-011613 P9F1ANK SFP-SX Xcvr 6 REV 01 740-011613 P9F1AP2 SFP-SX Xcvr 7 REV 01 740-011613 P9F1ALL SFP-SX Xcvr 8 REV 01 740-011613 P9F1ANM SFP-SX Xcvr 9 REV 01 740-011613 P9F1ANU SFP-SX PIC 1 BUILTIN BUILTIN 10x 1GE Xcvr 0 REV 01 740-011613 P9F18HA SFP-SX Xcvr 1 REV 01 740-011613 P9F18GY SFP-SX Xcvr 2 REV 01 740-011613 P9F18GL SFP-SX Xcvr 3 REV 01 740-011613 P9F18H3 SFP-SX Xcvr 4 REV 01 740-011613 P9F18GQ SFP-SX Xcvr 5 REV 01 740-011613 P9F18GX SFP-SX Xcvr 6 REV 01 740-011613 P9F18GK SFP-SX Xcvr 7 REV 01 740-011613 P9F18H7 SFP-SX Xcvr 8 REV 01 740-011613 P9F13JV SFP-SX Xcvr 9 REV 01 740-011613 P9F18GF SFP-SX PIC 2 BUILTIN BUILTIN 10x 1GE Xcvr 0 NON-JNPR P5A08SR SFP-T Xcvr 1 REV 01 740-007327 435040B00332 SFP-LX Xcvr 2 REV 01 740-011782 P8J1SZ4 SFP-SX Xcvr 3 REV 01 740-011782 P8J1SYH SFP-SX Xcvr 4 REV 01 740-011613 P9F18HB SFP-SX Xcvr 5 REV 01 740-011613 P9F1AN9 SFP-SX PIC 3 BUILTIN BUILTIN 10x 1GE Xcvr 0 REV 01 740-011613 P9F18GE SFP-SX Xcvr 1 REV 01 740-011613 P9F18GW SFP-SX Xcvr 2 REV 01 740-011613 P9F18H0 SFP-SX Xcvr 3 REV 01 740-011613 P9F18GG SFP-SX Xcvr 4 REV 01 740-011613 P9F18GD SFP-SX Xcvr 5 REV 01 740-013111 60882058 SFP-T Xcvr 6 REV 01 740-011613 P9F18GN SFP-SX Xcvr 8 REV 01 740-011613 P9F18GV SFP-SX Xcvr 9 REV 01 740-011613 P9F18H5 SFP-SX FPC 4 REV 04 710-014219 JS4980 MX960 4 XGE DPC CPU REV 03 710-013713 JS4164 MX960 DPC PMB PIC 0 BUILTIN BUILTIN 1x 10GE(LAN/WAN) Xcvr 0 NON-JNPR K9J02RS XFP-10G-LR PIC 1 BUILTIN BUILTIN 1x 10GE(LAN/WAN) Xcvr 0 NON-JNPR K9J03CY XFP-10G-LR PIC 2 BUILTIN BUILTIN 1x 10GE(LAN/WAN) Xcvr 0 REV 01 740-014279 62E204N00004 XFP-10G-LR PIC 3 BUILTIN BUILTIN 1x 10GE(LAN/WAN) FPC 7 REV 04 710-014219 JW7120 MX960 4 XGE DPC CPU REV 04 710-013713 JS4236 MX960 DPC PMB PIC 0 BUILTIN BUILTIN 1x 10GE(LAN/WAN) Xcvr 0 NON-JNPR K9J02T3 XFP-10G-LR PIC 1 BUILTIN BUILTIN 1x 10GE(LAN/WAN) Xcvr 0 NON-JNPR K9J03BQ XFP-10G-LR PIC 2 BUILTIN BUILTIN 1x 10GE(LAN/WAN) Xcvr 0 NON-JNPR K9J03DA XFP-10G-LR PIC 3 BUILTIN BUILTIN 1x 10GE(LAN/WAN) Xcvr 0 NON-JNPR K9J02Q0 XFP-10G-LR Fan Tray 0 REV 01 740-014971 FT0655 MX960 Fan Tray Fan Tray 1 REV 01 740-014971 FT0653 MX960 Fan Tray
Most components also have a small rectangular serial number ID label (see Figure 1) attached to the component body.