- play_arrow Fast Track: Initial Installation
- play_arrow Overview
- play_arrow System Overview
- play_arrow Chassis Components and Descriptions
- MX960 Chassis Description
- MX960 Component Redundancy
- MX960 Router Hardware and CLI Terminology Mapping
- MX960 Midplane Description
- MX960 Rack-Mounting Hardware
- MX960 Craft Interface Overview
- MX960 Alarm Relay Contacts on the Craft Interface
- MX960 Alarm LEDs and Alarm Cutoff/Lamp Test Button
- MX960 Component LEDs on the Craft Interface
- MX960 Cable Manager Description
- play_arrow Cooling System Components and Descriptions
- play_arrow Host Subsystem Components and Descriptions
- play_arrow Interface Modules—DPCs
- play_arrow Interface Modules—FPCs and PICs
- play_arrow Interface Modules—MPCs and MICs
- MX960 Application Services Modular Line Card Description
- MX960 Application Services Modular Storage Card Description
- MX960 Application Services Modular Processing Card Description
- MX960 AS MSC LEDs
- MX960 AS MXC LEDs
- MIC/MPC Compatibility
- MX960 Modular Interface Card Description
- MX960 Modular Interface Card (MIC) LEDs
- MICs Supported by MX Series Routers
- MX960 MIC Port and Interface Numbering
- MX960 Modular Port Concentrator Description
- MX960 Modular Port Concentrator LEDs
- MPCs Supported by MX Series Routers
- play_arrow Services Processing Card—MX-SPC3
- play_arrow Power System Components and Descriptions
- play_arrow Switch Control Board Components and Descriptions
-
- play_arrow Site Planning, Preparation, and Specifications
- play_arrow Preparation Overview
- play_arrow Transceiver and Cable Specifications
- play_arrow Pinout Specifications
- play_arrow AC Power Requirements, Specifications, and Guidelines
- play_arrow DC Power Requirements, Specifications, and Guidelines
- play_arrow High-Voltage Second-Generation Universal (HVAC or HVDC) Power Requirements, Specifications, and Guidelines
- Electrical Specifications for the MX960 High-Voltage Second-Generation Universal (HVAC/HVDC) Power Supply
- Power Requirements for an MX960 Router
- Calculating Power Requirements for MX960 Routers
- High-Voltage Second-Generation Universal (HVAC or HVDC) Power Circuit Breaker Requirements for the MX960 Router
- High-Voltage Second-Generation Universal (MX960-PSM-HV) Power Cord Specifications for the MX960 Router
-
- play_arrow Initial Installation and Configuration
- play_arrow Unpacking the MX960 Router
- play_arrow Installing the Mounting Hardware
- play_arrow Installing the MX960 Router
- Installing an MX960 Router Overview
- Removing Components from the MX960 Router Chassis Before Installing It with a Lift
- Tools Required to Install the MX960 Router with a Mechanical Lift
- Installing the MX960 Router Using a Mechanical Lift
- MX960 Acoustic Cover Installation Instructions
- MX960 Extended Cable Manager Installation Instructions
- Reinstalling Components in the MX960 Chassis After Installing It with a Lift
- play_arrow Connecting the MX960 Router to Power
- Tools and Parts Required for MX960 Router Grounding and Power Connections
- Grounding the MX960 Router
- Connecting Power to an AC-Powered MX960 Router with Normal-Capacity Power Supplies
- Connecting Power to an AC-Powered MX960 Router with High-Capacity Power Supplies
- Connecting Power to an AC-Powered MX960 Router with High-Capacity Second-Generation Power Supplies
- Powering On an AC-Powered MX960 Router with Normal Capacity Power Supplies
- Connecting Power to a DC-Powered MX960 Router with Normal-Capacity Power Supplies
- Connecting Power to a DC-Powered MX960 Router with High-Capacity Power Supplies
- Powering On a DC-Powered MX960 Router with Normal Capacity Power Supplies
- Connecting Power to an MX960 Router with High-Voltage Second-Generation Universal (HVAC or HVDC) Power Supplies
- Powering Off the MX960 Router
- Connecting an MX960 AC Power Supply Cord
- Connecting an MX960 DC Power Supply Cable
- play_arrow Connecting the MX960 Router to the Network
- Tools and Parts Required for MX960 Router Connections
- Connecting the MX960 Router to Management and Alarm Devices
- Connecting the MX960 Router to a Network for Out-of-Band Management
- Connecting the MX960 Router to a Management Console or Auxiliary Device
- Connecting an MX960 Router to an External Alarm-Reporting Device
- Connecting DPC, MPC, MIC, or PIC Cables to the MX960 Router
- Connecting the Alarm Relay Wires to the MX960 Craft Interface
- play_arrow Initially Configuring the MX960 Router
-
- play_arrow Installing and Replacing Components
- play_arrow Overview of Installing and Replacing Components
- play_arrow Installing Components
- Installing the MX960 Craft Interface
- Installing the MX960 Air Filter
- Installing an MX960 Fan Tray
- Installing an MX960 Routing Engine
- Installing an MX960 Switch Control Board
- Installing an MX960 DPC
- Installing an MX960 FPC
- Installing an MX960 MIC
- Installing an MX960 Dual-Wide MIC
- Installing an MX960 MPC
- Installing an MX960 PIC
- Installing a Cable on an MX960 DPC, MPC, MIC, or PIC
- Installing a MX960 AC Power Supply or High-Voltage Second-Generation Universal (HVAC or HVDC)
- Installing an MX960 DC Power Supply
- Installing an MX960 AS MLC
- Installing an MX960 AS MSC
- Installing an MX960 AS MXC
- Installing an SFP or XFP Transceiver into an MX960 DPC, MPC, MIC, or PIC
- Replacing a CFP2 Transceiver
- Replacing a CFP Transceiver
- play_arrow Replacing Chassis Components
- play_arrow Replacing Cooling System Component
- play_arrow Replacing Host Subsystem Components
- Replacing an MX960 Routing Engine
- Replacing an SSD Drive on an RE-S-1800
- Replacing an SSD Drive on an RE-S-X6-64G
- Replacing Connections to MX960 Routing Engine Interface Ports
- Upgrading to the RE-S-X6-64G Routing Engine in a Redundant Host Subsystem
- Upgrading to the RE-S-X6-64G Routing Engine in a Nonredundant Host Subsystem
- play_arrow Replacing Line Card Components
- play_arrow Replacing Power System Components
- play_arrow Replacing and Upgrading Switch Control Boards
-
- play_arrow Troubleshooting Hardware
- play_arrow Knowledge Base
- play_arrow Troubleshooting Components
-
- play_arrow Contacting Customer Support and Returning the Chassis or Components
- play_arrow Contacting Customer Support
- play_arrow Locating Component Serial Numbers
- Displaying MX960 Router Components and Serial Numbers
- MX960 Routing Engine Serial Number Label
- MX960 Chassis Serial Number and Agency Label
- MX960 Craft Interface Serial Number Label
- MX960 Fan Tray Serial Number Label
- MX960 Power Supply Serial Number Labels
- MX960 MIC Serial Number Label
- MX960 MPC Serial Number Label
- MX960 PIC Serial Number Label
- MX960 FPC Serial Number Label
- MX960 DPC Serial Number Label
- MX960 SCB Serial Number Label
- MX960 Midplane Serial Number Label
- Contact Customer Support
- play_arrow Packing and Returning Components
-
- play_arrow Safety and Compliance Information
- play_arrow General Safety Guidelines and Warnings
- play_arrow Installation and Maintenance Safety Guidelines and Warnings
- play_arrow Radiation and Laser Warnings
- play_arrow Maintenance and Operational Safety Guidelines and Warnings
- play_arrow Electrical Safety Guidelines and Warnings
- General Electrical Safety Guidelines and Warnings
- Prevention of Electrostatic Discharge Damage
- AC Power Electrical Safety Guidelines
- AC Power Disconnection Warning
- DC Power Copper Conductors Warning
- DC Power Disconnection Warning
- DC Power Grounding Requirements and Warning
- DC Power Wiring Sequence Warning
- DC Power Wiring Terminations Warning
- Midplane Energy Hazard Warning
- Multiple Power Supplies Disconnection Warning
- Action to Take After an Electrical Accident
- play_arrow Agency Approvals and Compliance Statements
- Agency Approvals for MX960 Routers
- Compliance Statements for NEBS for the MX960 Router
- Compliance Statements for EMC Requirements for the MX960 Router
- Compliance Statements for Environmental Requirements
- Compliance Statements for Acoustic Noise for the MX960 Router
- Statements of Volatility for Juniper Network Devices
-
Verifying the Version of the MX960 Cable Manager
Action
Issue the show chassis hardware
command.
In the following output, Extended Cable Manager in the Description field indicates that the
MX960 router has an extended cable manager installed.
user@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis JN10BA496AFA MX960 Midplane REV 03 710-013698 TR0193 MX960 Backplane Fan Extender REV 02 710-018051 JY5226 Extended Cable Manager FPM Board REV 03 710-014974 JZ6867 MX960 Front Panel Display PDM Rev 03 740-013110 QCS11035022 Power Distribution Module PEM 0 Rev 03 740-013683 QCS1104706T DC Power Entry Module PEM 1 Rev 03 740-013683 QCS11047071 DC Power Entry Module PEM 2 Rev 03 740-013683 QCS1110700A DC Power Entry Module PEM 3 Rev 03 740-013683 QCS11107006 DC Power Entry Module Routing Engine 0 REV 06 740-013063 1000690747 RE-S-2000 Routing Engine 1 REV 06 740-013063 1000690717 RE-S-2000 CB 0 REV 07 710-013385 KA3976 MX SCB CB 1 REV 07 710-013385 KA2127 MX SCB CB 2 REV 07 710-013385 KA2122 MX SCB FPC 0 REV 06 710-013699 JZ8103 DPCE 40x 1GE X CPU REV 06 710-013713 JZ7349 DPC PMB PIC 0 BUILTIN BUILTIN 10x 1GE(LAN) Xcvr 0 REV 01 740-011783 PB93302 SFP-LX Xcvr 1 REV 01 740-011613 AM0703S02F5 SFP-SX Xcvr 2 REV 01 740-011613 AM0703S02EV SFP-SX Xcvr 3 REV 01 740-011613 AM0703S02EN SFP-SX Xcvr 4 REV 01 740-011613 AM0703S02FD SFP-SX Xcvr 5 REV 01 740-011783 PB93RLK SFP-LX Xcvr 6 REV 01 740-011783 PB9292T SFP-LX Xcvr 7 REV 01 740-011613 AM0703S02EC SFP-SX Xcvr 8 REV 01 740-011783 PB9296B SFP-LX Xcvr 9 REV 01 740-011783 PB9294X SFP-LX PIC 1 BUILTIN BUILTIN 10x 1GE(LAN) Xcvr 0 REV 01 740-011783 PB9330R SFP-LX Xcvr 1 REV 01 740-011613 PB349PQ SFP-SX Xcvr 2 REV 01 740-011613 AM0703S02F1 SFP-SX Xcvr 3 REV 01 740-011613 PB3494J SFP-SX Xcvr 4 REV 01 740-011613 AM0703S02EY SFP-SX Xcvr 5 REV 01 740-011613 AM0703S02F3 SFP-SX Xcvr 6 REV 01 740-011613 AM0703S02EX SFP-SX Xcvr 7 REV 01 740-011613 AM0703S02EZ SFP-SX Xcvr 8 REV 01 740-011613 AM0703S02ET SFP-SX Xcvr 9 REV 01 740-011613 AM0703S02G8 SFP-SX PIC 2 BUILTIN BUILTIN 10x 1GE(LAN) Xcvr 0 REV 01 740-011783 PB92938 SFP-LX Xcvr 1 REV 01 740-011613 AM0703S02E0 SFP-SX Xcvr 2 REV 01 740-011613 AM0703S02F6 SFP-SX Xcvr 3 REV 01 740-011613 AM0703S02FB SFP-SX Xcvr 4 REV 01 740-011613 AM0703S02FA SFP-SX Xcvr 5 REV 01 740-011613 AM0703S02ED SFP-SX Xcvr 6 REV 01 740-011783 PB9338R SFP-LX Xcvr 7 REV 01 740-011613 AM0703S02E1 SFP-SX Xcvr 8 REV 01 740-011783 PB929AU SFP-LX Xcvr 9 REV 01 740-011783 PB929AV SFP-LX PIC 3 BUILTIN BUILTIN 10x 1GE(LAN) Xcvr 0 REV 01 740-011783 PB9330Q SFP-LX Xcvr 1 REV 01 740-011613 AM0703S02E8 SFP-SX Xcvr 2 REV 01 740-011613 PB34FPU SFP-SX Xcvr 3 REV 01 740-011613 PB34FZ4 SFP-SX Xcvr 4 REV 01 740-011613 PB34N3Q SFP-SX Xcvr 5 REV 01 740-011613 AM0703S02EL SFP-SX Xcvr 6 REV 01 740-011613 AM0703S02EG SFP-SX Xcvr 7 REV 01 740-011613 AM0703S02EJ SFP-SX Xcvr 8 REV 01 740-011783 PB9292Y SFP-LX Xcvr 9 REV 01 740-011783 PB9296A SFP-LX FPC 3 REV 08 710-014219 KA1048 DPCE 4x 10GE X CPU REV 06 710-013713 JZ7177 DPC PMB PIC 0 BUILTIN BUILTIN 1x 10GE(LAN/WAN) Xcvr 0 REV 01 740-014279 6Z3019A00247 XFP-10G-LR PIC 1 BUILTIN BUILTIN 1x 10GE(LAN/WAN) Xcvr 0 REV 01 740-014279 723019A00434 XFP-10G-LR PIC 2 BUILTIN BUILTIN 1x 10GE(LAN/WAN) Xcvr 0 REV 01 740-014289 C712XU00S XFP-10G-SR PIC 3 BUILTIN BUILTIN 1x 10GE(LAN/WAN) Xcvr 0 REV 01 740-014279 6Z3019A00216 XFP-10G-LR Fan Tray 0 REV 03 740-014971 TP0730 Fan Tray Fan Tray 1 REV 03 740-014971 TP0451 Fan Tray