Optical ILA Power Supply LEDs
Each optical ILA power supply has two LEDs on the power supply faceplate. Figure 1 shows the location of the LEDs on an optical ILA AC power supply. Figure 2 shows the location of the LEDs on an optical ILA DC power supply.
1 — DC OK | 2 — AC OK |
1 — DC OUT OK | 2 — DC IN OK |
Use Table 1 and Table 2 to interpret the state of the power supply LEDs.
Name |
Color |
State |
Description |
---|---|---|---|
DC OK (left side of FRU panel) |
Unlit |
Off |
There is no power to any of the power supplies. |
Green |
Blinking (1 Hz) |
The power supply is present and only on standby mode. |
|
On steadily |
The power supply output is on and operating correctly. |
||
Red |
On steadily |
There is a power supply failure. |
|
Blinking (0.5 Hz) |
No AC power to this power supply only. |
||
AC OK (right side of FRU panel) |
Unlit |
Off |
There is no power to any of the power supplies. |
Green |
On steadily |
The power supply is present and only on standby mode. |
|
On steadily |
The power supply output is on and operating correctly. |
||
Red |
On steadily |
There is a power supply failure. |
|
Blinking (0.5 Hz) |
No AC power to this power supply only. |
Name |
Color |
State |
Description |
---|---|---|---|
DC OUT OK (left side of FRU panel) |
Unlit |
Off |
There is no power to the power supplies. |
Green |
On steadily |
The power supply DC output is on and operating correctly. |
|
Blinking ((1 Hz)) |
The power supply is present and on standby mode. |
||
Red |
On steadily |
There is a power supply failure. |
|
Blinking (0.5 Hz) |
There is no DC power to this power supply only. |
||
DC IN OK (right side of the FRU panel) |
Unlit |
Off |
There is no power to the power supplies. |
Green |
On steadily |
The power supply is present and on standby mode. |
|
On steadily |
The power supply DC output is on and operating correctly. |
||
Red |
On steadily |
There is a power supply failure. |
|
Blinking (0.5 Hz) |
There is no DC power to this power supply only. |