Configuring a Two-Degree IPLC Node for Express Traffic by Increasing the Line Capacity
For metro linear and metro ring topologies that require either north-south or east-west communications, you can connect two IPLC base modules together to form a two-degree IPLC node. This enables you to run express traffic in two directions. This topic describes how to setup and configure an IPLC two-degree node.
Using the express-in software capability of the IPLC, you can configure the IPLC to accept a wavelength from another IPLC residing in the same chassis. For example, when you have configured an IPLC node using two IPLC base modules. This topic describes how to express-in a wavelength from one IPLC to another IPLC within the same chassis.
Before you begin, complete the following tasks:
Install and connect the two IPLC base modules through the PT IN and PT OUT ports. These two IPLC modules form the two-line IPLC node.
Best Practice:We recommend that you place the IPLC modules into the same FPC or PIC slot pair on the PTX3000 chassis.
To configure the IPLC for two-line terminations to express-in a wavelength from another IPLC: