falling-threshold (percentage)

date_range 19-Nov-23

Syntax

content_copy zoom_out_map
falling-threshold percentage;

Hierarchy Level

content_copy zoom_out_map
[edit snmp health-monitor],
[edit snmp health-monitor idp]

Description

Set the lower threshold for the monitored object when you configure a health monitor alarm. By setting a rising and a falling threshold for a monitored variable, you can be alerted whenever the value of the variable falls outside the allowable operational range.

Options

percentage—The lower threshold for the alarm entry.

  • Range: 1 through 100

  • Default: 70 percent of the maximum possible value

Required Privilege Level

snmp—To view this statement in the configuration.

snmp-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 8.0.