profile (Security Antivirus Juniper Express Engine)
Syntax
profile profile-name { fallback-options { content-size (block | log-and-permit); default (block | log-and-permit); engine-not-ready (block | log-and-permit); out-of-resources (block | (log-and-permit); timeout (block | log-and-permit); too-many-requests (block | log-and-permit); } notification-options { fallback-block { administrator-email email-address; allow-email; custom-message message; custom-message-subject message-subject; display-host; (notify-mail-sender | no-notify-mail-sender); type (message | protocol-only); } fallback-non-block { custom-message message; custom-message-subject message-subject; (notify-mail-recipient | no-notify-mail-recipient); } virus-detection { custom-message message; custom-message-subject message-subject; (notify-mail-sender | no-notify-mail-sender); type (message | protocol-only); } } scan-options { content-size-limit value; (intelligent-prescreening | no-intelligent-prescreening); timeout value; } trickling { timeout value; } }
Hierarchy Level
[edit security utm default-configuration] [edit security utm feature-profile anti-virus juniper-express-engine]
Description
Create a profile for the Juniper express engine. This profile includes all subsequent configuration options.
Options
The remaining statements are explained separately. See CLI Explorer.
Required Privilege Level
security—To view this statement in the configuration.
security-control—To add this statement to the configuration.
Release Information
The express engine feature is not supported from Junos OS Release 15.1X49-D10 onwards. For previous releases, statement introduced in Junos OS Release 9.5.
The [edit security utm default-configuration]
hierarchy
level is introduced in Junos OS Release 18.2R1.