show system errors fru
Syntax
show system errors fru detail [fru slot-number]
Description
Display information collected by the J-Insight fault monitoring feature. Specifically, display information about detected errors based on the FRU.
Options
none | Display a brief summary of the system error information for the FRU. |
detail | (Optional) Display detailed system error information. |
fru slot-number | (Optional) Display system error information for a specific FRU. For devices running Junos OS, output displays error details for FPC FRUs. For devices running Junos OS Evolved, output displays error details for FPC and other components such as fan, PSM, CB, and chassis. |
Required Privilege Level
admin
Output Fields
Table 1 lists the output fields for the show system errors fru
command. Output fields are listed in the approximate order in which
they appear.
Field Name |
Field Description |
---|---|
FRU |
FRU identification number. |
Scope |
An error scope provides a level of classification above error category. Error scope values are: pfe and board. |
Category |
An error category categorizes errors into various subgroups under a specific error scope level. Values include: functional, io, memory, processing, storage, and switch. |
Level |
Severity level of the error. |
Occurred |
Number of times errors of a specific scope, category, and severity level has occurred. |
Cleared |
Number of times errors of a specific scope, category, and severity level were cleared. |
Threshold |
Configured threshold value. The associated detection and recovery actions are triggered when this value is exceeded. |
Action-Taken |
Number of times a user-configured recovery action was triggered for errors of a specific scope, category, and severity level. |
Action |
Action that is triggered when the threshold value is exceeded. |
Sample Output (Junos OS)
- show system errors fru detail
- show system errors fru detail (MX240, MX480, MX960, MX2008, MX2010, MX2020)
show system errors fru detail
user@host> show system errors fru detail Fru Scope Category Level Occurred Cleared Threshold Action-Taken Action FPC 0 board functional Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE memory Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE io Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE storage Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE switch Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE processing Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE pfe functional Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE memory Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE io Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE storage Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE switch Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE processing Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE
show system errors fru detail (MX240, MX480, MX960, MX2008, MX2010, MX2020)
user@host> show system errors fru detail Fru Scope Category Level Occurred Cleared Threshold Action-Taken Action FPC 0 board functional Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE memory Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE io Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE storage Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE switch Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE processing Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 DISABLE PFE pfe functional Minor 0 0 1 0 LOG|CM ALARM| Major 0 0 1 0 LOG| RESET PFE
Sample Output (Junos OS Evolved)
show system errors fru detail (PTX10003)
The following output has been shortened for clarity. For each part of a FRU, the full output displays any errors in the functional, io, memory, processing, storage, and switch categories, similar to the CB 0 FRU below.
user@host> show system errors fru detail Fru Scope Category Level Occurred Cleared Threshold Action-Taken Action CB 0 board functional Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 CM ALARM|RESET io Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 CM ALARM|RESET memory Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 CM ALARM|RESET processing Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 CM ALARM|RESET storage Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 CM ALARM|RESET switch Minor 0 0 10 0 LOG| Major 0 0 1 0 GET STATE|CM ALARM| Fatal 0 0 1 0 CM ALARM|RESET CHASSIS 0 board ... FAN 0 board ... FAN 1 board ... FPC 0 board ... pfe ... FPC 1 board ... pfe ... FPM 0 board ... PDU 0 board ... PICS 0 board ... PICS 1 board ... PSM 0 board ... PSM 1 board ... RE 0 board ... SIB 0 board ... switch ... SIB 1 board ... switch ...
Release Information
Command introduced in Junos OS Release 18.2R1.
Reset-pfe option added in Junos OS Release 21.4R1.