Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 
 

quality-level (hybrid)

Syntax

Hierarchy Level

Description

Configure the quality level for the timing source so that the router knows the best available source with which to synchronize. The quality level specifies the accuracy level of the clock.

Options

prs —Primary reference source—Stratum 1

st2—Stratum 2

tnc—Transit node clock

st3e—Stratum 3E

st3—Stratum 3

smc—SONET minimum clock

st4—Stratum 4

prc—Primary reference clock

ssu-a—Synchronization supply unit A

ssu-b—Synchronization supply unit B

sec—SDH equipment clock

Required Privilege Level

routing—To view this statement in the configuration.

routing-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 12.2R2.