quality-level (hybrid)

date_range 27-Sep-24

Syntax

content_copy zoom_out_map
quality-level (prs | st2 | tnc | st3e | st3 | smc | st4) | (prc | ssu-a | ssu-b | sec);

Hierarchy Level

content_copy zoom_out_map

Description

Configure the quality level for the timing source so that the router knows the best available source with which to synchronize. The quality level specifies the accuracy level of the clock.

Options

prs —Primary reference source—Stratum 1

st2—Stratum 2

tnc—Transit node clock

st3e—Stratum 3E

st3—Stratum 3

smc—SONET minimum clock

st4—Stratum 4

prc—Primary reference clock

ssu-a—Synchronization supply unit A

ssu-b—Synchronization supply unit B

sec—SDH equipment clock

Required Privilege Level