fru-poweron-sequence
Syntax
fru-poweron-sequence fru-poweron-sequence;
Hierarchy Level
[edit chassis]
Description
(MX Series 5G Universal Routing Platforms, SRX5xxx Series Platforms) Configure the power-on sequence for the DPCs in the chassis for routers with the enhanced AC Power Entry Module (PEM).
(T640 routers, T1600 routers, T4000 routers, MX2020 routers, and PTX Series packet transport routers) Configure the power-on sequence for Flexible PIC Concentrators (FPCs) installed in the chassis.
Options
(MX Series 5G Universal Routing Platforms only)
fru-poweron-sequence
—Power-on
sequence for the DPCs in the chassis. The numbers indicate the slot
number of the DPCs.
If the power-on sequence is not configured by including the
fru-poweron-sequence
statement,
Junos OS uses the
/var/log/fpc_poweron_seq.log
file
to determine the power-on sequence for the last power-on
operation for the DPCs and the same sequence is used. If the
/var/log/boot_seq.log
file, is not
available, Junos OS uses the ascending order of the slot
numbers of the DPCs as the sequence to power on the
DPCs.
(T640 routers, T1600 routers, T4000 routers, MX2020 routers, and PTX
Series packet transport routers)
fru-poweron-sequence
—Power-on
sequence for the FPCs in the chassis. The numbers indicate the slot
number of the FPCs.
-
If the configured sequence contains invalid numbers, Junos OS considers only the valid numbers in the sequence. The invalid numbers are silently discarded.
-
If the power-on sequence is not configured by including the
fru-poweron-sequence
statement, Junos OS uses the ascending order of the slot numbers of the FPCs as the sequence to power on the FPCs.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 10.0.