threshold (PIM BFD Transmit Interval)

date_range 20-Nov-23

Syntax

content_copy zoom_out_map
threshold milliseconds;

Hierarchy Level

content_copy zoom_out_map
[edit protocols pim interface interface-name bfd-liveness-detection transmit-interval],
[edit routing-instances routing-instance-name protocols pim interface interface-name bfd-liveness-detection transmit-interval]

Description

Specify the threshold for the adaptation of the BFD session transmit interval. When the transmit interval adapts to a value greater than the threshold, a single trap and a single system message are sent.

Options

milliseconds—Value for the transmit interval adaptation threshold.

  • Range: 0 through 4,294,967,295 (232 – 1)

    Note:

    The threshold value specified in the threshold statement must be greater than the value specified in the minimum-interval statement for the transmit-interval statement.

Required Privilege Level

routing—To view this statement in the configuration.

routing-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 8.2.