hold-down
Syntax
hold-down { seconds; flaps number; period seconds; }
Hierarchy Level
[edit logical-systems logical-system-name routing-options bmp], [edit logical-systems logical-system-name routing-options bmp station station-name], [edit routing-options bmp], [edit routing-options bmp station station-name]
Description
If the connection to a BMP station flaps and the hold-down
statement is configured, the station is prevented
from reconnecting to the device for the specified period of time.
A flap is when the TCP session unexpectedly switches from established
to non-established. If you alter the configuration of the hold-down
statement, the hold down timer and flap counter are reset.
You can effectively disable the hold-down
statement
by setting the flaps
option to 10 and the period
option to 30 seconds.
Options
seconds |
Specify the time in seconds to wait before allowing the BMP station to reconnect to the device.
|
flaps number |
Specify the number of BMP station flaps allowed before terminating the connection to the BMP station and triggering the hold down timer.
|
period seconds |
Specify the time in seconds for the BGP
station flaps (specified using the For example, if you defined the
|
Required Privilege Level
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 13.2X51-D15.