show chassis cluster ethernet-switching status
Syntax
show chassis cluster ethernet-switching status
Description
Display the Ethernet switching status of the chassis cluster.
Required Privilege Level
view
Output Fields
Table 1 lists
the output fields for the show chassis cluster ethernet-switching
status
command. Output fields are listed in the approximate
order in which they appear.
Field Name |
Field Description |
---|---|
|
ID number (1-255) of a cluster. Setting a cluster ID to 0 is equivalent to disabling a cluster. A cluster ID greater than 15 can only be set when the fabric and control link interfaces are connected back-to-back. |
|
You can create up to 128 redundancy groups in the chassis cluster. |
|
Node (device) in the chassis cluster ( |
|
Assigned priority for the redundancy group on that node. |
|
State of
the redundancy group (
|
|
|
|
|
Sample Output
show chassis cluster ethernet-switching status
user@host> show chassis cluster ethernet-switching status Monitor Failure codes: CS Cold Sync monitoring FL Fabric Connection monitoring GR GRES monitoring HW Hardware monitoring IF Interface monitoring IP IP monitoring LB Loopback monitoring MB Mbuf monitoring NH Nexthop monitoring NP NPC monitoring SP SPU monitoring SM Schedule monitoring CF Config Sync monitoring Cluster ID: 1 Node Priority Status Preempt Manual Monitor-failures Redundancy group: 0 , Failover count: 0 node0 1 primary no no None node1 1 secondary no no None Ethernet switching status: Probe state is UP. Both nodes are in single ethernet switching domain(s).
Release Information
Command introduced in Junos OS Release 11.1.