Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 
 

show services rpm rfc2544-benchmarking

Syntax

Description

Display information about the results of each category or state of the RFC 2544-based benchmarking test, such as terminated tests, active tests, and completed tests, for each real-time performance monitoring (RPM) instance. You can view the results of each test state for all of the configured test IDs or for a specific test ID. Also, you can display statistics about the total number of tests of each state for a high-level, quick analysis. The values in the output displayed vary, depending on the state in which the test is passing through, when you issue the command.

You can view the test results of multiple test IDs at the same time by entering the IDs in a single command. If you enter multiple test ID values, you must separate each number with a space.

Options

none

Display test results for all categories.

aborted-tests

(Optional) Display the list of tests that were terminated or stopped. This list includes tests that failed due to various error conditions and tests that you terminated by entering the test service rpm rfc2544-benchmarking test test-name stop command. The Status field in the output specifies the reason for the termination of the test.

active-tests

(Optional) Display the results of the set of tests that are currently running.

brief | detail | extensive

Display the specified level of output.

completed-tests

(Optional) Display the results of the set of tests that were successfully completed. A completed test is one that passes through all the test steps or states specified in RFC 2544. A test that is marked as completed after it went through all the states from the beginning to the end can still be reported as a failed test. For example, a failed test can be a test that sends the desired number of packets, but does not receive the frames back from the other end.

summary

(Optional) Display summary output.

test-id test-id

Display test results for the specified unique identifier of the test.

Required Privilege Level

view

Output Fields

Table 1 lists the output fields for the show services rpm rfc2544-benchmarking command. Output fields are listed in the approximate order in which they appear.

Table 1: show services rpm rfc2544-benchmarking Output Fields

Field Name

Field Description

Test information

Details of the performed RFC 2544 benchmarking test.

Test id

Unique identifier configured for the test.

Test name

Name configured for the test.

Test type

The type of statistical detail that is collected for the test, based on the configured test type. Throughput-related, latency, frame-loss, or back-to-back frames-related information is displayed for ACX Series routers. Reflected packets-related information is displayed for MX104 Series routers.

Test mode

Mode configured for the test on the router. Test modes are:

  • Initiate-and-Terminate: Test frames are initiated from one end and terminated at the same end. This mode requires a reflector to be configured at the peer end to enable the test frames to be returned to the source. This mode is supported only on ACX Series routers.

  • Reflect: Test frames that originate from one end are reflected at the other end on the selected service, such as IPv4 or Ethernet.

Test packet size

Size of the test packets in bytes. This field is valid only when the test mode is Initiate-and-Terminate.

Test state

State of the test that is in progress or active when the output is displayed.

Status

Indicates whether the test is currently in progress or has been terminated. This field is displayed for tests that are in progress or were terminated by entering the test services rpm rfc2544-benchmarking test <test-name | test-id> stop command.

Test start time

Time at which the test started in Coordinated Universal Time (UTC) format (YYYY-MM-DD-HH:MM:SS).

Test finish time

Time at which the test completed.

Counters last cleared

Date, time, and how long ago the statistics for the test were cleared. The format is year-month-day hour:minute:second:timezone (hour:minute:second ago). For example, 2010-05-17 07:51:28 PDT (00:04:33 ago). If you did not clear the statistics previously at any point, Never is displayed.

Number of active tests

Total number of tests that are currently running.

Number of completed tests

Total number of tests that were successfully completed

Number of aborted tests

Total number of tests that were terminated or halted.

Sample Output

show services rpm rfc2544-benchmarking summary

This output indicates that no test iteration is currently in progress (at the time of issue of the command), 4 tests were completed successfully, and 52 tests were halted.

show services rpm rfc2544-benchmarking aborted-tests (ACX Series Router)

show services rpm rfc2544-benchmarking completed-tests (ACX Series Router)

show services rpm rfc2544-benchmarking active-tests (ACX Series Router)

show services rpm rfc2544-benchmarking aborted-tests (MX104 Router)

show services rpm rfc2544-benchmarking completed-tests (MX104 Router)

show services rpm rfc2544-benchmarking active-tests (MX104 Router)

show services rpm rfc2544-benchmarking aborted-tests (SRX300 and SRX550HM)

show services rpm rfc2544-benchmarking active-tests (SRX300 and SRX550HM)

show services rpm rfc2544-benchmarking completed-tests (SRX300 and SRX550HM)

show services rpm rfc2544-benchmarking aborted-tests detail (SRX300 and SRX550HM)

Release Information

Command introduced in Junos OS Release 12.3X52.