frequency-lock-threshold

Syntax

Hierarchy Level

Description

The frequency lock threshold option controls the frequency offset in parts per billion (ppb) that the servo will lock with. Locking with a higher frequency lock threshold allows a quicker frequency lock, although at the expense of a higher phase offset per window in the phase aligned state. This option can be used for PTP applications that do not demand strict requirements that are typically needed with telecom applications.

Options

frequency-offset

The frequency offset value in parts per billion (ppb).

  • Range: 1 ppb through 15 ppb

  • Default: 1 ppb

Required Privilege Level

routing—To view this statement in the configuration.

routing-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 23.4R1 for MX10008.

Supported on ACX7100-32C, ACX7100-48L, and ACX7024 in Junos OS Evolved Release 24.2R1.