polling-interval
Syntax
polling-interval seconds;
Hierarchy Level
[edit protocols sflow], [edit protocols sflow interfaces interface-name]
Description
Configure the interval (in seconds) that the device waits between port statistics update messages. Polling refers to the device successively gathering various statistics for the network interfaces configured for sFlow monitoring and exporting the statistics to the configured sFlow collector.
Default
If no polling interval is configured for a particular
interface, the device uses the global polling interval configured
at the [edit protocols sflow]
hierarchy level. If no global
interval is configured, the device uses the default polling interval
of 20 seconds.
Options
seconds—Number of seconds between successive samples of interface statistics. Specifying a value of 0 (zero) disables the polling.
Range: 0 through 3600 seconds
Default: 20 seconds
Required Privilege Level
routing—To view this statement in the configuration.routing-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.3.