show chassis lcd

date_range 19-Nov-23

show chassis lcd (EX Series)

content_copy zoom_out_map
show chassis lcd
<fpc-slot fpc-slot-number>
<menu <(all-members | local | member member-id)>>

show chassis lcd (QFX Series)

content_copy zoom_out_map
show chassis lcd
<fpc-slot fpc-slot-number>
<interconnect-device device-id>
<node-device device-id>

show chassis lcd (OCX Series)

content_copy zoom_out_map
show chassis lcd
<fpc-slot fpc-slot-number>

Description

Display the information that appears on the LCD panel of EX3200, EX3300, EX4200, EX4500, EX6200, and EX8200 switches, XRE200 External Routing Engines, QFX Series standalone switches, OCX Series switches, and Interconnect devices and Node devices within a QFabric system. Display the status of the currently selected port parameter of the Status LED for each network port on the device.

Options

none

Display the information that appears on the LCD panel (for any EX Series member switch in a Virtual Chassis or for XRE200 External Routing Engines, display the information for all Virtual Chassis members). Display the status of the currently selected port parameter of the Status LED for each network port.

fpc-slot <fpc-slot-number>

(Optional) Display the information as follows:

  • (EX3200, EX3300, EX4200, and EX4500 switches, QFX Series, or OCX Series) Display the information that appears on the LCD panel for either an FPC slot with no fpc-slot-number value specified or for the FPC slot specified by fpc-slot 0. fpc-slot refers to the switch itself and 0 is the only valid value for fpc-slot-number. Output for these options is the same as for the none option.

    Also display the status of the currently selected port parameter of the Status LED for each network port.

  • (EX Series Virtual Chassis member switches or XRE200 External Routing Engines) If no fpc-slot-number value is specified, display the information that appears on the LCD panel for all members of the Virtual Chassis. Output for this option is the same as for the none option. If the fpc-slot-number value is specified (it equals the member-id value), display the information for the specified member.

    Also display the status of the currently selected port parameter of the Status LED for each network port.

  • (EX6200 or EX8200 switches)—Display the information that appears on the LCD panel for the line card in the line-card slot specified by the fpc-slot-number value.

    Also display the status of the currently selected port parameter of the Status LED for each network port.

interconnect-device device-id

(QFabric systems only) (Optional) Display the front panel contents and LED status of all the ports on the Interconnect device.

menu

(Optional) Display the names of the menus and menu options that are currently enabled on the LCD panel.

menu all-members

(EX Series Virtual Chassis member switches or XRE200 External Routing Engines) (Optional) Display the names of the menus and menu options that are currently enabled on the LCD panel for all Virtual Chassis members.

menu local

(EX Series Virtual Chassis member switches or XRE200 External Routing Engines) (Optional) Display the names of the menus and menu options that are currently enabled on the LCD panel for the Virtual Chassis member from which you issued the command.

menu member member-id

(EX Series Virtual Chassis member switches or XRE200 External Routing Engines) (Optional) Display the names of the menus and menu options that are currently enabled on the LCD panel for the specified Virtual Chassis member.

node-device device-id

(QFabric systems only) (Optional) Display the front panel contents and LED status of all the ports on the Node device.

Required Privilege Level

view

Output Fields

Table 1 lists the output fields for the show chassis lcd command. Output fields are listed in the approximate order in which they appear.

Table 1: show chassis lcd Output Fields

Field Name

Field Description

membernumber (XRE200 External Routing Engine)

Member ID of the device whose content is being displayed.

Front panel contents for slot

Front panel contents (EX6200, EX8200 switch, XRE200 External Routing Engine, and QFX Series)

FPC slot number of the switch whose content is being displayed. The number is always 0, except for EX4200 switches in a Virtual Chassis, where it is the member ID value.

On EX6200 switches, EX8200 switches, and XRE200 External Routing Engines, no slot number is displayed.

On XRE200 External Routing Engines, this field appears under the member number field for each member device in the EX8200 Virtual Chassis.

LCD screen

The first line displays the hostname (for Virtual Chassis members, displays the member ID, the current role, and hostname; for EX8200 switches, displays RE and the hostname). The second line displays the currently selected port parameter of the Status LED and the alarms counter. The Status LED port parameters are:

  • ADM—Administrative

  • SPD—Speed

  • DPX—Duplex

  • POE—Power over Ethernet (EX3200 and EX4200 switches only)

LEDs status

Current state of the Alarms, System, and Master LEDs (chassis status LEDs).

Interface

Names of the interfaces on the switch.

LED (ADM/SPD/DPX/POE)

State of the currently selected port parameter of the Status LED for the interface. The Status LED port parameters are:

Note:

The XRE200 External Routing Engine always displays the NA parameter. The QFX Series products do not have any of the port parameters listed below.

  • ADM—Administrative

  • SPD—Speed

  • DPX—Duplex

  • NA—Not applicable.

  • POE—Power over Ethernet

fpcx

On standalone EX Series and QFX Series switches, always 0. On EX Series Virtual Chassis member switches, member ID of the Virtual Chassis member whose LCD menu is displayed.

Sample Output

show chassis lcd (Two-Member EX4200 Virtual Chassis)

content_copy zoom_out_map
user@switch> show chassis lcd 
Front panel contents for slot: 0
---------------------------------
LCD screen:
    00:BK switch1
    LED:SPD ALARM 00
LEDs status:
    Alarms LED: Off
    System LED: Green
    Master LED: Off
Interface       LED(ADM/SPD/DPX/POE)
-------------------------------------
ge-0/0/0        Off
ge-0/0/1        Off
ge-0/0/2        Off
ge-0/0/3        Off
ge-0/0/4        Off
ge-0/0/5        Off
ge-0/0/6        Off
ge-0/0/7        Off
ge-0/0/8        Off
ge-0/0/9        Off
ge-0/0/10       Off
ge-0/0/11       Off
ge-0/0/12       Off
ge-0/0/13       Off
ge-0/0/14       Off
ge-0/0/15       Off
ge-0/0/16       Off
ge-0/0/17       Off
ge-0/0/18       Off
ge-0/0/19       Off
ge-0/0/20       Off
ge-0/0/21       Off
ge-0/0/22       Off
ge-0/0/23       Off
Front panel contents for slot: 1
---------------------------------
LCD screen:
    01:RE switch2
    LED:SPD ALARM 01
LEDs status:
    Alarms LED: Yellow
    System LED: Green
    Master LED: Green
Interface       LED(ADM/SPD/DPX/POE)
-------------------------------------
ge-1/0/0        Off
ge-1/0/1        Off
ge-1/0/2        Off
ge-1/0/3        Off
ge-1/0/4        Off
ge-1/0/5        Off
ge-1/0/6        Off
ge-1/0/7        Off
ge-1/0/8        Off
ge-1/0/9        Off
ge-1/0/10       Off
ge-1/0/11       Off
ge-1/0/12       Off
ge-1/0/13       Off
ge-1/0/14       Off
ge-1/0/15       Off
ge-1/0/16       Off
ge-1/0/17       Off
ge-1/0/18       Off
ge-1/0/19       Off
ge-1/0/20       Off
ge-1/0/21       Off
ge-1/0/22       Off
ge-1/0/23       Off
			

The output for the show chassis lcd fpc-slot command is the same as the output for the show chassis lcd command.

show chassis lcd fpc-slot 1 (EX4200 Virtual Chassis)

content_copy zoom_out_map
user@switch> show chassis lcd fpc-slot 1 
Front panel contents for slot: 1
---------------------------------
LCD screen:
    01:RE switch2
    LED:SPD ALARM 01
LEDs status:
    Alarms LED: Yellow
    System LED: Green
    Master LED: Green
Interface       LED(ADM/SPD/DPX/POE)
-------------------------------------
ge-1/0/0        Off
ge-1/0/1        Off
ge-1/0/2        Off
ge-1/0/3        Off
ge-1/0/4        Off
ge-1/0/5        Off
ge-1/0/6        Off
ge-1/0/7        Off
ge-1/0/8        Off
ge-1/0/9        Off
ge-1/0/10       Off
ge-1/0/11       Off
ge-1/0/12       Off
ge-1/0/13       Off
ge-1/0/14       Off
ge-1/0/15       Off
ge-1/0/16       Off
ge-1/0/17       Off
ge-1/0/18       Off
ge-1/0/19       Off
ge-1/0/20       Off
ge-1/0/21       Off
ge-1/0/22       Off
ge-1/0/23       Off

show chassis lcd (EX8200 Switch)

content_copy zoom_out_map
user@switch> show chassis lcd 
Front panel contents:
---------------------
LCD screen:
    RE st-8200-r
    LED:ADM ALARM 01
LEDs status:
    Alarms LED: Yellow
    System LED: Yellow
    Master LED: Green
Interface       LED(ADM/SPD/DPX)
------------------------------------------
ge-0/0/0        Off
ge-0/0/1        Off
ge-0/0/2        Off
ge-0/0/3        Off
ge-0/0/4        Off
ge-0/0/5        Off
ge-0/0/6        Off
ge-0/0/7        Off
ge-0/0/8        Off
ge-0/0/9        Off
ge-0/0/10       Off
ge-0/0/11       Off
ge-0/0/12       Off
ge-0/0/13       Off
ge-0/0/14       Off
ge-0/0/15       Off
ge-0/0/16       Off
ge-0/0/17       Off
ge-0/0/18       Off
ge-0/0/19       Off
ge-0/0/20       Off
ge-0/0/21       Off
ge-0/0/22       Off
ge-0/0/23       Off
ge-0/0/24       Off
ge-0/0/25       Off
ge-0/0/26       Off
ge-0/0/27       Off
ge-0/0/28       Off
ge-0/0/29       Off
ge-0/0/30       Off
ge-0/0/31       Off
ge-0/0/32       Off
ge-0/0/33       Off
ge-0/0/34       Off
ge-0/0/35       Off
ge-0/0/36       Off
ge-0/0/37       Off
ge-0/0/38       Off
ge-0/0/39       Off
ge-0/0/40       Off
ge-0/0/41       Off
ge-0/0/42       Off
ge-0/0/43       Off
ge-0/0/44       Off
ge-0/0/45       Off
ge-0/0/46       Off
ge-0/0/47       Off
xe-2/0/0        Off
xe-2/0/1        Off
xe-2/0/2        Off
xe-2/0/3        Off
xe-2/0/4        Off
xe-2/0/5        Off
xe-2/0/6        Off
xe-2/0/7        Off
xe-3/0/0        Off
xe-3/0/1        Off
xe-3/0/2        Off
xe-3/0/3        Off
xe-3/0/4        Off
xe-3/0/5        Off
xe-3/0/6        Off
xe-3/0/7        Off
xe-5/0/0        Off
xe-5/0/1        Off
xe-5/0/2        Off
xe-5/0/3        Off
xe-5/0/4        Off
xe-5/0/5        Off
xe-5/0/6        On
xe-5/0/7        On
xe-7/0/5        Off

show chassis lcd fpc-slot 2 (EX8200 Switch)

content_copy zoom_out_map
show chassis lcd fpc-slot 2

Interface       LED(ADM/SPD/DPX)
------------------------------------------
xe-2/0/0        Off
xe-2/0/1        Off
xe-2/0/2        Off
xe-2/0/3        Off
xe-2/0/4        Off
xe-2/0/5        Off
xe-2/0/6        Off
xe-2/0/7        Off

show chassis lcd menu (EX4200 Switch)

content_copy zoom_out_map
user@switch> show chassis lcd menu
fpc0:
--------------------------------------------------------------------------
status-menu
status-menu vcp-status
status-menu power-status
status-menu environ-menu
status-menu show-version
maintenance-menu
maintenance-menu halt-menu
maintenance-menu system-reboot
maintenance-menu rescue-config
maintenance-menu vc-uplink-config
maintenance-menu factory-default

On an EX4200 switch in a Virtual Chassis, the output for the show chassis lcd menu all-members command is the same as the output for the show chassis lcd menu command.

show chassis lcd menu (EX8200 Switch)

content_copy zoom_out_map
user@switch> show chassis lcd menu
status-menu
status-menu sf-status1-menu
status-menu sf-status2-menu
status-menu psu-status1-menu
status-menu psu-status2-menu
status-menu environ-menu
status-menu show-version
maintenance-menu
maintenance-menu halt-menu
maintenance-menu system-reboot
maintenance-menu rescue-config
maintenance-menu factory-default

show chassis lcd (QFX3500 Switches)

content_copy zoom_out_map
user@switch> show chassis lcd 
Front panel contents for slot: 0
---------------------------------
LCD screen:
00:RE switch
ALARM 01
LEDs status:
Status/Beacon LED: Yellow Blinking
Interface STATUS LED ACTIVITY LED
-------------------------------------------
fte-0/1/0 Off Off

show chassis lcd (XRE200 External Routing Engine in EX8200 Virtual Chassis)

content_copy zoom_out_map
user@external-routing-engine> show chassis lcd 
member0:
--------------------------------------------------------------------------
Front panel contents:
---------------------
LCD screen:
    RE ex8200-member0
    LED:ADM ALARM 04
LEDs status:
    Alarms LED: Red
    System LED: Yellow
    Master LED: Green

member1:
--------------------------------------------------------------------------

member8:
--------------------------------------------------------------------------
Front panel contents:
---------------------
LCD screen:
    BACKUP

member9:
--------------------------------------------------------------------------
Front panel contents:
---------------------
LCD screen:
    09:RE xre200-member9
    LED: NA ALARM 01
Interface       LED(ADM/SPD/DPX/POE)
------------------------------------------
ge-0/0/0        On
ge-0/0/1        On
ge-0/0/2        On
ge-0/0/3        On
ge-0/0/4        Off
ge-0/0/5        Off
ge-0/0/6        Off
ge-0/0/7        Off
ge-0/0/8        Off
ge-0/0/9        Off
ge-0/0/10       On
ge-0/0/11       Off
ge-0/0/12       Off
ge-0/0/13       Off
ge-0/0/14       Off
ge-0/0/15       Off
ge-0/0/16       Off
ge-0/0/17       Off
ge-0/0/18       Off
ge-0/0/19       Off
ge-0/0/20       Off
ge-0/0/21       Off
ge-0/0/22       Off
ge-0/0/23       Off
ge-0/0/24       Off
ge-0/0/25       Off
ge-0/0/26       Off
ge-0/0/27       Off
ge-0/0/28       Off
ge-0/0/29       Off
ge-0/0/30       Off
ge-0/0/31       Off
ge-0/0/32       Off
ge-0/0/33       Off
ge-0/0/34       Off
ge-0/0/35       Off
ge-0/0/36       Off
ge-0/0/37       Off
ge-0/0/38       Off
ge-0/0/39       Off
ge-0/0/40       On
ge-0/0/41       On
ge-0/0/42       On
ge-0/0/43       On
ge-0/0/44       On
ge-0/0/45       On
ge-0/0/46       On
ge-0/0/47       On
ge-16/0/0       On
ge-16/0/1       Off
ge-16/0/2       On
ge-16/0/3       Off
ge-16/0/4       On
ge-16/0/5       Off
ge-16/0/6       On
ge-16/0/7       Off
ge-16/0/8       Off
ge-16/0/9       Off
ge-16/0/10      Off
ge-16/0/11      Off
ge-16/0/12      Off
ge-16/0/13      On
ge-16/0/14      Off
ge-16/0/15      On
ge-16/0/16      Off
ge-16/0/17      On
ge-16/0/18      On
ge-16/0/19      On
ge-16/0/20      On
ge-16/0/21      Off
ge-16/0/22      On
ge-16/0/23      Off
ge-16/0/24      Off
ge-16/0/25      Off
ge-16/0/26      On
ge-16/0/27      Off
ge-16/0/28      Off
ge-16/0/29      Off
ge-16/0/30      On
ge-16/0/31      Off
ge-16/0/32      On
ge-16/0/33      On
ge-16/0/34      On
ge-16/0/35      Off
ge-16/0/36      On
ge-16/0/37      Off
ge-16/0/38      Off
ge-16/0/39      Off
ge-16/0/40      Off
ge-16/0/41      Off
ge-16/0/42      On
ge-16/0/43      Off
ge-16/0/44      Off
ge-16/0/45      Off
ge-16/0/46      Off
ge-16/0/47      Off
xe-19/0/0       Off
xe-19/0/1       On
xe-19/0/2       On
xe-19/0/3       On
xe-19/0/4       On
xe-19/0/5       On
ge-22/0/0       Off
ge-22/0/1       Off
ge-22/0/2       On
ge-22/0/3       Off
ge-22/0/4       On
ge-22/0/5       On
ge-22/0/6       On
ge-22/0/7       On
ge-22/0/8       Off
ge-22/0/9       Off
ge-22/0/10      Off
ge-22/0/11      Off
ge-22/0/12      Off
ge-22/0/13      Off
ge-22/0/14      Off
ge-22/0/15      Off
ge-22/0/16      On
ge-22/0/17      Off
ge-22/0/18      On
ge-22/0/19      Off
ge-22/0/20      On
ge-22/0/21      Off
ge-22/0/22      On
ge-22/0/23      Off
ge-22/0/24      On
ge-22/0/25      Off
ge-22/0/26      Off
ge-22/0/27      Off
ge-22/0/28      Off
ge-22/0/29      Off
ge-22/0/30      Off
ge-22/0/31      Off
ge-22/0/32      On
ge-22/0/33      Off
ge-22/0/34      On
ge-22/0/35      Off
ge-22/0/36      Off
ge-22/0/37      Off
ge-22/0/38      Off
ge-22/0/39      Off
ge-22/0/40      Off
ge-22/0/41      Off
ge-22/0/42      Off
ge-22/0/43      Off
ge-22/0/44      Off
ge-22/0/45      Off
ge-22/0/46      Off
ge-22/0/47      Off

show chassis lcd interconnect-device (QFabric Systems)

content_copy zoom_out_map
show chassis lcd interconnect-device IC-F1012
                Front Panel Module Information
                ---------------------------------
                LCD screen:
                IC-F1012        3 Alarms active 
LEDs status:
    Status LED: Green  
    Power LED : Green  
    Major Alarm LED: off    
    Minor Alarm LED: Yellow 
    Fan 0 LED : Green  
    Fan 1 LED : Green  
    Fan 2 LED : Green  
    Fan 3 LED : Green  
    Fan 4 LED : Green  
    Fan 5 LED : Green  
    Fan 6 LED : Green  
    Fan 7 LED : Green  
    Fan 8 LED : Green  
    Fan 9 LED : Green  
    PEM 0 LED : Green  
    PEM 1 LED : Green  
    PEM 2 LED : Green  
    PEM 3 LED : off    
    PEM 4 LED : off    
    PEM 5 LED : off    

                LED info for: CB - 0
                ---------------------------------
LEDs status:
    Status LED: Green  
    Mastership LED: Green  

Interface               STATUS LED      LINK/ACTIVITY LED
---------------------------------------------------------
IC-F1012:pme0 :         Green           N/A
IC-F1012:pme1 :         Green           N/A
IC-F1012:pme2 :         off             N/A
IC-F1012:pme3 :         off             N/A

                LED info for: CB - 1
                ---------------------------------
LEDs status:
    Status LED: Green  
    Mastership LED: Amber  

Interface               STATUS LED      LINK/ACTIVITY LED
---------------------------------------------------------
IC-F1012:pme0 :         Green           N/A
IC-F1012:pme1 :         Green           N/A
IC-F1012:pme2 :         off             N/A
IC-F1012:pme3 :         off             N/A

                LED info for: FC 0 FPC - 0
                ---------------------------------
LEDs status:
    Status LED: Green  

Interface               STATUS LED      LINK/ACTIVITY LED
---------------------------------------------------------
IC-F1012:fte-0/0/0      Green           N/A
IC-F1012:fte-0/0/1      Green           N/A
IC-F1012:fte-0/0/2      Green           N/A
IC-F1012:fte-0/0/3      Green           N/A
IC-F1012:fte-0/0/4      Green           N/A

                LED info for: FC 1 FPC - 1
                ---------------------------------
LEDs status:
    Status LED: Green  

Interface               STATUS LED      LINK/ACTIVITY LED
---------------------------------------------------------
IC-F1012:fte-1/0/0      Green           N/A
IC-F1012:fte-1/0/1      Green           N/A
IC-F1012:fte-1/0/2      Green           N/A
IC-F1012:fte-1/0/3      Green           N/A
IC-F1012:fte-1/0/4      Green           N/A

                LED info for: RC 0 FPC - 8
                ---------------------------------
LEDs status:
    Status LED: Green  

                LED info for: RC 1 FPC - 9
                ---------------------------------
LEDs status:
    Status LED: Green  

                LED info for: RC 2 FPC - 10
                ---------------------------------
LEDs status:
    Status LED: Green  

                LED info for: RC 3 FPC - 11
                ---------------------------------
LEDs status:
    Status LED: Green  

                LED info for: RC 4 FPC - 12
                ---------------------------------
LEDs status:
    Status LED: Green  

                LED info for: RC 5 FPC - 13
                ---------------------------------
LEDs status:
    Status LED: Green  

                LED info for: RC 6 FPC - 14
                ---------------------------------
LEDs status:
    Status LED: Green  

                LED info for: RC 7 FPC - 15
                ---------------------------------
LEDs status:
    Status LED: Green

show chassis lcd node-device (QFabric Systems)

content_copy zoom_out_map
show chassis lcd node-device P3774-C
                Front panel contents for: P3774-C
                -----------------------------------
                LCD screen:
                P3774-C          
LEDs status:
    Status/Beacon LED: Yellow Blinking

Interface               STATUS LED      LINK/ACTIVITY LED
---------------------------------------------------------
P3774-C:xe-0/0/6        Green           Green
P3774-C:xe-0/0/7        Green           Green
P3774-C:ge-0/0/10       Green           Green
P3774-C:ge-0/0/11       Green           Green Blinking
P3774-C:ge-0/0/12       Green           Off
P3774-C:ge-0/0/13       Green           Green Blinking
P3774-C:ge-0/0/20       Green           Green
P3774-C:ge-0/0/21       Green           Green
P3774-C:ge-0/0/22       Green           Green Blinking
P3774-C:ge-0/0/23       Green           Off
P3774-C:ge-0/0/30       Green           Green
P3774-C:ge-0/0/31       Green           Green
P3774-C:ge-0/0/32       Green           Green Blinking
P3774-C:ge-0/0/33       Green           Green Blinking
P3774-C:fte-0/1/0       Green           Green
P3774-C:fte-0/1/1       Green           Green Blinking
P3774-C:fte-0/1/2       Green           Green Blinking
P3774-C:fte-0/1/3       Green           Green

Release Information

Command introduced in Junos OS Release 9.0.

menu option introduced in Junos OS Release 10.2 for EX Series switches.

footer-navigation