Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 
 

fpc (PTX Series Devices)

Syntax (PTX Series Devices)

Hierarchy Level

Description

Configure properties for the PICs in individual Flexible PIC Concentrators (FPCs). Configure FPC Restart, offline and online (PTX10003 devices only).

Options

slot-number—Slot number in which the FPC is installed.

  • Range: From 0 to maximum slot number based on the product type.

    For example:

    • For PTX1000 and PTX10001-36MR devices, the FPC slot number is always 0.
    • For PTX10008 device, the slot number range is 0 to 7.
    • For PTX10016 device, the range is 0 to 15,
    • For PTX10003 device, FPC Restart, offline and online options are available.

    • For PTX3000 devices, alternate slot numbers 0, 2, 4, 6, 8, 10, 12, 14).

pfe—Slot number in which the PFE is installed. If FPC power off is set along with PFE power ON, then PFE power ON is not initiated.

sampling-instance instance_string— You can configure active sampling using a sampling instance and associate that sampling instance to a Flexible Port Concentrator (FPC), Modular Port Concentrator (MPC), or Dense Port Concentrator (DPC). In addition, you can define multiple sampling instances associated with multiple destinations and protocol families per sampling instance destination.

Sampling-instances are defined under the [edit forwarding-options] hierarchy.

traffic-manager— You can configure traffic manager attributes for the FPC. Available options are enhanced-priority-mode and no-enhanced-priority-mode.

The remaining statements are explained separately, for example ,error.

Note:

The fpc <fpc-slot> pfe <pfe-inst> power-off configuration is added to power-off specific PFE instances when an FPC is brought online or to power-off a PFE during runtime.

Note:

Click on the highlighted links in the Syntax section to view details of other available configuration options. Using the configuration command for error levels, you can isolate PFE errors, thereby reducing the need for a field replacement of FPCs. For feature details and PTX platforms supported, see FPC self-healing.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced before Junos OS Release 7.4.

Error statement introduced for PTX Series devices in Junos OS Release 13.3.