fpc (PTX Series Devices)
Syntax (PTX Series Devices)
fpc slot-number { error pfe pic sampling-instance instance_string; traffic-manager { (enhanced-priority-mode | no-enhanced-priority-mode) } optical-options }
Hierarchy Level
[edit chassis]
Description
Configure properties for the PICs in individual Flexible PIC Concentrators (FPCs). Configure FPC Restart, offline and online (PTX10003 devices only).
Options
slot-number
—Slot number in which the FPC is
installed.
-
Range: From 0 to maximum slot number based on the product type.
For example:
- For PTX1000 and PTX10001-36MR devices, the FPC slot number is always 0.
- For PTX10008 device, the slot number range is 0 to 7.
- For PTX10016 device, the range is 0 to 15,
-
For PTX10003 device, FPC Restart, offline and online options are available.
- For PTX3000 devices, alternate slot numbers 0, 2, 4, 6, 8, 10, 12, 14).
pfe
—Slot number in which the PFE is
installed. If
FPC power off is set along with PFE power ON, then PFE power ON is not
initiated.
sampling-instance instance_string
— You can configure active
sampling using a sampling instance and associate that sampling instance to a
Flexible Port Concentrator (FPC), Modular Port Concentrator (MPC), or Dense Port
Concentrator (DPC). In addition, you can define multiple sampling instances
associated with multiple destinations and protocol families per sampling instance
destination.
Sampling-instances are defined under the [edit forwarding-options]
hierarchy.
traffic-manager
— You can configure traffic manager attributes for
the FPC. Available options are enhanced-priority-mode
and
no-enhanced-priority-mode
.
The remaining statements are explained separately, for example ,error.
The fpc <fpc-slot> pfe <pfe-inst> power-off
configuration is added to
power-off specific PFE instances when an FPC is brought online or to power-off a
PFE during runtime.
Click on the highlighted links in the Syntax section to view details of other available configuration options. Using the configuration command for error levels, you can isolate PFE errors, thereby reducing the need for a field replacement of FPCs. For feature details and PTX platforms supported, see FPC self-healing.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release Information
Statement introduced before Junos OS Release 7.4.
Error statement introduced for PTX Series devices in Junos OS Release 13.3.