date_range 19-Nov-23

Syntax

content_copy zoom_out_map
initial-route-check seconds;

Hierarchy Level

content_copy zoom_out_map
[edit interfaces dln unit logical-unit-number dialer-options]

Description

On J Series Services Routers with ISDN interfaces, allows the router to check whether the primary route is up after the initial startup of the router is complete and the timer expires.

Options

seconds—How long to wait to check if the primary interface is up after the router comes up.

  • Range: 1 through 300 seconds

  • Default: 120 seconds

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced before Junos OS Release 7.4.