Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 
 

routing-instance-list (TWAMP)

Syntax

Hierarchy Level

Description

Configure the Two-Way Active Measurement Protocol (TWAMP) servers on specific routing instances, instead of associating the TWAMP server at the system-level to apply to all routing instances configured on a router. The default routing instance is Internet routing table inet.0. If you do not specify a routing instance, the TWAMP probe applies to all routing instances. To apply the TWAMP probe to only the default routing instance, you must explicitly set the value of instance-name to default. If an interface is not part of any routing instance, the default port is used for TWAMP probes. You can configure up to 100 routing instances for a TWAMP server.

Options

instance-name—Name of the routing instance, a maximum of 31 characters.

number—Port number.

  • Range: 1 through 65,535

Required Privilege Level

system—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1.