request chassis redundancy feb slot
Syntax
request chassis redundancy feb slot slot-number (switch-to-backup | revert-from-backup)
Description
(M120 routers only) Control the operation of the specified Forwarding Engine Board (FEB) in a redundancy group.
Options
slot-number | FEB slot number. Replace slot-number with a value from 0 through 5. |
switch-to-backup | Initiate a switchover from the specified active FEB to the backup FEB for the redundancy group. |
revert-from-backup | Initiate a revert to the specified FEB following a switchover from the backup FEB for a redundancy group. |
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
- request chassis redundancy feb slot 2 switch-to-backup
- request chassis redundancy feb slot 3 revert-from-backup
request chassis redundancy feb slot 2 switch-to-backup
user@host> request chassis redundancy feb slot 2 switch-to-backup Switch initiated, use “show chassis redundancy febs” to verify
request chassis redundancy feb slot 3 revert-from-backup
user@host> request chassis redundancy feb slot 3 revert-from-backup Revert initiated, use “show chassis redundancy febs” to verify
Release Information
Command introduced in Junos OS Release 8.2.