duration (PoE)

date_range 20-Nov-23

Syntax

content_copy zoom_out_map
duration hours;

Hierarchy Level

content_copy zoom_out_map
[edit poe interface (all | interface-name) telemetries]

Description

Modifies the duration for which telemetry records are stored. If telemetry logging continues beyond the specified duration, the older records are discarded one by one as new records are collected.

Options

hours— Hours for which telemetry data should be retained.

  • Range: 1 through 24 hours

  • Default: 1 hour

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9.5.