gate-status
Syntax
gate-status (uplink | downlink | uplink-downlink | disable-both);
Hierarchy Level
[edit unified-edge pcef pcc-action-profiles profile-name], [edit services pcef pcc-action-profiles profile-name]
Description
Configure the gate status in a PCC action profile to enable or disable the forwarding of service flow packets. The gate status determines whether the uplink and downlink gates are opened or closed.
If you are using Junos OS Subscriber Aware, configure the gate
status at the [edit unified-edge pcef pcc-action-profiles profile-name]
hierarchy level.
If you are using Junos OS Broadband Subscriber Management, configure
the gate status at the [edit services pcef pcc-action-profiles profile-name]
hierarchy level.
Default
By default, if this statement is not configured, forwarding of service data flow packets is enabled in both the uplink and downlink directions.
Options
disable-both | Disable forwarding of service data flow packets in the uplink and downlink directions. |
downlink | Enable forwarding of service data flow packets in the downlink direction. |
uplink-downlink | Enable forwarding of service data flow packets in the uplink and downlink directions. |
uplink | Enable forwarding of service data flow packets in the uplink direction. |
Required Privilege Level
For Junos OS Subscriber Aware:
unified-edge—To view this statement in the configuration.
unified-edge-control—To add this statement to the configuration.
For Junos OS Broadband Subscriber Management:
services—To view this statement in the configuration.
services–control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 17.1.
Support
at the [edit services pcef pcc-action-profiles profile-name]
hierarchy level introduced for Junos OS Broadband Subscriber
Management in Junos OS Release 17.2 on MX Series.
Support for Next Gen Services for Junos OS Broadband Subscriber Management introduced in Junos OS Release 19.3R2 on MX Series.