odu-signal-degrade
Syntax
odu-signal-degrade { ber-threshold-clear; ber-threshold-signal-degrade; interval }
Hierarchy Level
[edit interfaces interface-name otn-options]
Description
Specify optical channel data unit (ODU) signal degradation threshold-related values.
Default
If you omit the odu-signal-degrade
statement,
the default threshold values are used.
The following are the default threshold values for optical channel data unit (ODU) signal degradation for the P2-100GE-OTN PIC:
ber-threshold-clear
—1E-09interval
—10 ms
The following are the default threshold values for optical channel data unit (ODU) signal degradation for the MPC5E and the MIC6-100G-CFP2 MIC:
ber-threshold-clear
—1.14E-5ber-threshold-signal-degrade
—1.0E-6interval
—10 ms
Options
The remaining statements are explained separately. See CLI Explorer.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 14.1R2.